ANALOG MULTIPLEXED CABLE TELEMETRY (AMT) ELECTROMYOGRAPH, MODELS AMT-16, AMT-8 & AMT-4

FDA 510(k)
FDA Class 2 ·Physical Medicine

Natus

FDA UDI
Technomed Engineering B.V.·08718375865903·Grass® Disposable Deep EEG Cup Electrode, Silve...

GLUCOSE CONTROL SOLUTION FOR THERASENSE FREESTYLE

FDA 510(k)
FDA Class 1 ·Clinical Chemistry

LYRA SERIES SURGICAL LASER SYSTEM (SL SERIES, ND:YAG CONFIGURATION)

FDA 510(k)
FDA Class 2 ·General, Plastic Surgery

SEXTANT

FDA Adverse Event
Malfunction ·MEDTRONIC SOFAMOR DANEK·Product code KWQ·October 1, 2010

CRYSTALENS INTRAOCULAR LENS

FDA Adverse Event
Injury ·BAUSCH & LOMB, INC.·Product code NAA·February 25, 2015

COBAS 8000 ISE 900 MODULE

FDA Adverse Event
Malfunction ·ROCHE DIAGNOSTICS·Product code JJE·February 13, 2023

840 VENTILATOR

FDA Adverse Event
Malfunction ·COVIDIEN, FORMERLY NELLCOR...·Product code CBK·February 27, 2013

CAREASSIST BED

FDA Adverse Event
Malfunction ·HILL-ROM PLUVIGNER·Product code FNL·February 15, 2011

COLLEAGUE CX VOLUMETRIC INFUSION PUMP

FDA Adverse Event
Malfunction ·BAXTER HEALTHCARE PTE. LTD.·Product code FRN·April 3, 2008

PENUMBRA SMART COIL

FDA Adverse Event
Injury ·PENUMBRA, INC.·Product code HCG·October 18, 2021

GE Healthcare, Discovery MR750 3.0T, Optima MR450w 1.5T, and Discovery MR450 1.5T . scanner designed to support high resolution, high signal-to-noise ratio, and short scan times. The GE Signa MR 750 System is indicated for use as a diagnostic imaging device to produce axial, sagittal, coronal, and oblique images, spectroscopic images, parametric maps, and/or spectra, dynamic images of the structures and organs of the entire body, including but not limited to, head, neck, TMJ, spine, breast, heart, abdomen, pelvis, joints, prostate, blood vessels, and musculoskeletal regions of the body. The images produced by the GE Signa MR 750 System reflect the spatial distribution or molecular environment of nuclei exhibiting magnetic resonance. These images when interpreted by a trained physician yield information that may assist in diagnosis. The indications for use for the 3.0T GE Signa MR750 System are similar to those for the Signa HDx Magnetic Resonance System and the Siemens MAGNETOM Verio MR System. K113490: The Optima" MR450w is a whole body magnetic resonance scanner designed to support high resolution, high signal-to-noise ratio, and short scan times. It is indicated for use as a diagnostic imaging device to produce axial, sagittal, coronal, and oblique images, spectroscopic images, parametric maps, and/or spectra, dynamic images of the structures and/or functions of the entire body, including but not limited to, head, neck, TMJ, spine, breast, heart, abdomen, pelvis, joints, prostate, blood vessels, and musculoskeletal regions of the body. Depending on the region of interest being images, contrast agents may be used. The images produced by the Optima" MR 450w reflect the spatial distribution or molecular environment of nuclei exhibiting magnetic resonance. These images and/or spectra when interpreted by a trained physician yield information that may assist in diagnosis. K083147: The Discovery MR 450 is a whole body magnetic resonance scanner designed to support high resolution, high signal-to-noise ratio, and short scan times. It is indicated for use as a diagnostic imaging device to produce axial, sagittal, coronal, and oblique images spectroscopic images parametric maps, and/or spectra, dynamic images of the structures and/or functions of the entire body, including, but not limited to, head, neck, TMJ, spine, breast, heart, abdomen, pelvis, joints, prostate, blood vessels, and musculoskeletal regions of the body. Depending on the region of interest being imaged, contrast agents may be used. The images produced by the Discovery MR450 reflect the spatial distribution or molecular environment of nuclei exhibiting magnetic resonance. These images and/or spectra when interpreted by a trained physician yield information that may assist in diagnosis.

FDA Recall
Terminated ·GE Healthcare, LLC·Product code LNH·August 13, 2013

GE Healthcare, Discovery MR750 3.0T, Optima MR450w 1.5T, and Discovery MR450 1.5T . scanner designed to support high resolution, high signal-to-noise ratio, and short scan times. The GE Signa¿ MR 750 System is indicated for use as a diagnostic imaging device to produce axial, sagittal, coronal, and oblique images, spectroscopic images, parametric maps, and/or spectra, dynamic images of the structures and organs of the entire body, including but not limited to, head, neck, TMJ, spine, breast, heart, abdomen, pelvis, joints, prostate, blood vessels, and musculoskeletal regions of the body. The images produced by the GE Signa¿ MR 750 System reflect the spatial distribution or molecular environment of nuclei exhibiting magnetic resonance. These images when interpreted by a trained physician yield information that may assist in diagnosis. The indications for use for the 3.0T GE Signa¿ MR750 System are similar to those for the Signa¿ HDx Magnetic Resonance System and the Siemens MAGNETOM Verio MR System. K113490: The Optima" MR450w is a whole body magnetic resonance scanner designed to support high resolution, high signal-to-noise ratio, and short scan times. It is indicated for use as a diagnostic imaging device to produce axial, sagittal, coronal, and oblique images, spectroscopic images, parametric maps, and/or spectra, dynamic images of the structures and/or functions of the entire body, including but not limited to, head, neck, TMJ, spine, breast, heart, abdomen, pelvis, joints, prostate, blood vessels, and musculoskeletal regions of the body. Depending on the region of interest being images, contrast agents may be used. The images produced by the Optima" MR 450w reflect the spatial distribution or molecular environment of nuclei exhibiting magnetic resonance. These images and/or spectra when interpreted by a trained physician yield information that may assist in diagnosis. K083147: The Discovery MR 450 is a whole body magnetic resonance scanner designed to support high resolution, high signal-to-noise ratio, and short scan times. It is indicated for use as a diagnostic imaging device to produce axial, sagittal, coronal, and oblique images spectroscopic images parametric maps, and/or spectra, dynamic images of the structures and/or functions of the entire body, including, but not limited to, head, neck, TMJ, spine, breast, heart, abdomen, pelvis, joints, prostate, blood vessels, and musculoskeletal regions of the body. Depending on the region of interest being imaged, contrast agents may be used. The images produced by the Discovery MR450 reflect the spatial distribution or molecular environment of nuclei exhibiting magnetic resonance. These images and/or spectra when interpreted by a trained physician yield information that may assist in diagnosis.

FDA Enforcement
Class II ·Terminated·GE Healthcare, LLC·October 9, 2013

Alaris System PC Unit Model 8000, a modular infusion pump and monitoring system

FDA Enforcement
Class I ·Terminated·CareFusion 303, Inc.·August 12, 2020

CADD-Solis VIP ambulatory Infusion Pumps, Model 2110. Indicated for the following uses: Intra-arterial, subcutaneous, intraperitoneal, in close proximity to nerves, into an intraoperative site, epidural space or subarachnoid space. Therapies that require a continuous rate of infusion, intermittent bolus, and/or with patient-controlled demand doses.

FDA Enforcement
Class I ·Ongoing·Smiths Medical ASD Inc.·August 14, 2024