10,000 results · 40ms · Sources: EU EUDAMED, US FDA

Get notified when this changes

We'll email you when new records match this search — new devices, new clearances, certificate changes, or withdrawals.

ARROW

FDA UDI
TELEFLEX INCORPORATED·10801902114195·SureBlock(R) Spinal Anesthesia Kit with 0.75% B...

ARROW

FDA UDI
TELEFLEX INCORPORATED·10801902114140·SureBlock(R) Spinal Anesthesia Kit with 0.75% B...

ARROW

FDA UDI
TELEFLEX INCORPORATED·10801902114157·SureBlock(R) Spinal Anesthesia Kit with 0.75% B...

ARROW

FDA UDI
TELEFLEX INCORPORATED·10801902114164·SureBlock(R) Spinal Anesthesia Kit with 0.75% B...

ARROW

FDA UDI
TELEFLEX INCORPORATED·10801902114171·SureBlock(R) Spinal Anesthesia Kit with 0.75% B...

EYEVAN

FDA UDI
EYEVAN INC.·04582669032692·

EYEVAN

FDA UDI
EYEVAN INC.·04571445056182·

EYEVAN

FDA UDI
EYEVAN INC.·04582667980841·

EYEVAN

FDA UDI
EYEVAN INC.·04571445036665·

EYEVAN

FDA UDI
EYEVAN INC.·04582667976165·

AMPLATZER Exchange System 45-degree curve, order no. 9-EXCH-12F-45/80. Product is labeled as Sterile EO. The AMPLATZER Exchange System is comprised of the identical components as the AMPLATZER Delivery System, which is comprised of delivery sheath, delivery cable, dilator, loading device and pin vise. The only exception is the dilator component in the Exchange System has a larger inner lumen to allow passage over an AMPLATZER delivery cable. Exchange Systems are placed onto polyboard backing cards. The backing card is then placed into a smaller of 2 Tyvek pouches. The pouch is then placed inside a larger Tyvek pouch. The kit is assembled at AGA and then sterilized by Steris, Minneapolis, MN.

FDA Recall
Terminated ·AGA Medical Corporation·Product code GBK·November 23, 2004

AMPLATZER Delivery System 180-degree curve, order no. 9-DEL-9F-180/80. Product is labeled as Sterile EO. Amplatzer Occluder Device and Delivery System is comprised of delivery sheath, delivery cable, dilator, loading device and pin vise. The Delivery and Exchange Systems are placed onto polyboard backing cards. The backing card is then placed into a smaller of 2 Tyvek pouches. The pouch is then placed inside a larger Tyvek pouch. The kit is assembled at AGA and then sterilized by Steris, Minneapolis, MN.

FDA Recall
Terminated ·AGA Medical Corporation·Product code GBK·November 23, 2004

AMPLATZER Delivery System 180-degree curve, order no. 9-DEL-6F-180/80. Product is labeled as Sterile EO. Amplatzer Occluder Device and Delivery System is comprised of delivery sheath, delivery cable, dilator, loading device and pin vise. The Delivery and Exchange Systems are placed onto polyboard backing cards. The backing card is then placed into a smaller of 2 Tyvek pouches. The pouch is then placed inside a larger Tyvek pouch. The kit is assembled at AGA and then sterilized by Steris, Minneapolis, MN.

FDA Recall
Terminated ·AGA Medical Corporation·Product code GBK·November 23, 2004

AMPLATZER Delivery System 45-degree curve, order no. 9-DEL-9F-45/80. Product is labeled as Sterile EO. Amplatzer Occluder Device and Delivery System is comprised of delivery sheath, delivery cable, dilator, loading device and pin vise. The Delivery and Exchange Systems are placed onto polyboard backing cards. The backing card is then placed into a smaller of 2 Tyvek pouches. The pouch is then placed inside a larger Tyvek pouch. The kit is assembled at AGA and then sterilized by Steris, Minneapolis, MN.

FDA Recall
Terminated ·AGA Medical Corporation·Product code GBK·November 23, 2004

AMPLATZER Delivery System 45-degree curve, order no. 9-DEL-12F-45/80. Product is labeled as Sterile EO. Amplatzer Occluder Device and Delivery System is comprised of delivery sheath, delivery cable, dilator, loading device and pin vise. The Delivery and Exchange Systems are placed onto polyboard backing cards. The backing card is then placed into a smaller of 2 Tyvek pouches. The pouch is then placed inside a larger Tyvek pouch. The kit is assembled at AGA and then sterilized by Steris, Minneapolis, MN.

FDA Recall
Terminated ·AGA Medical Corporation·Product code GBK·November 23, 2004

Amplatzer Cardiac Septal Occluder delivery system Exchange Systems labeled as follows: a) AMPLATZER Exchange System, Order no. 9-EXCH-6F-180/80, 9-EXCH-8F-180/80, 9EXCH-9F-45/80, 9-EXCH-12F-45/80. [Breakdown of order no. ''9-EXCH-6F180/80'' is as follows: 9-EXCH, French size (6F) - degree angle curve (180) / usable length in cm (80).] and b) the following devices are not approved for US distribution: AMPLATZER TorqVue Exchange System, Order no. 9-EITV09F45/80, 9-EITV12F45/80, 9-EITV06F180/80, 9-EITV08F180/80. Manufactured in USA, Sterile EO. Headquarters AGA Medical Corporation, 682 Mendelssohn Avenue, Golden Valley, MN 55427 U.S.A. The Exchange System is comprised of a delivery sheath, delivery cable, dilator, loading device and pin vise.

FDA Recall
Terminated ·AGA Medical Corporation·Product code GBK·October 2, 2006

AMPLATZER Exchange System 45-degree curve, order no. 9-EXCH-9F-45/80. Product is labeled as Sterile EO. The AMPLATZER Exchange System is comprised of the identical components as the AMPLATZER Delivery System, which is comprised of delivery sheath, delivery cable, dilator, loading device and pin vise. The only exception is the dilator component in the Exchange System has a larger inner lumen to allow passage over an AMPLATZER delivery cable. Exchange Systems are placed onto polyboard backing cards. The backing card is then placed into a smaller of 2 Tyvek pouches. The pouch is then placed inside a larger Tyvek pouch. The kit is assembled at AGA and then sterilized by Steris, Minneapolis, MN.

FDA Recall
Terminated ·AGA Medical Corporation·Product code GBK·November 23, 2004

AMPLATZER Delivery System 45-degree curve, order no. 9-DEL-8F-45/80. Product is labeled as Sterile EO. Amplatzer Occluder Device and Delivery System is comprised of delivery sheath, delivery cable, dilator, loading device and pin vise. The Delivery and Exchange Systems are placed onto polyboard backing cards. The backing card is then placed into a smaller of 2 Tyvek pouches. The pouch is then placed inside a larger Tyvek pouch. The kit is assembled at AGA and then sterilized by Steris, Minneapolis, MN.

FDA Recall
Terminated ·AGA Medical Corporation·Product code GBK·November 23, 2004

AMPLATZER Exchange System 180-degree curve, order no. 9-EXCH-8F-180/80. Product is labeled as Sterile EO. The AMPLATZER Exchange System is comprised of the identical components as the AMPLATZER Delivery System, which is comprised of delivery sheath, delivery cable, dilator, loading device and pin vise. The only exception is the dilator component in the Exchange System has a larger inner lumen to allow passage over an AMPLATZER delivery cable. Exchange Systems are placed onto polyboard backing cards. The backing card is then placed into a smaller of 2 Tyvek pouches. The pouch is then placed inside a larger Tyvek pouch. The kit is assembled at AGA and then sterilized by Steris, Minneapolis, MN.

FDA Recall
Terminated ·AGA Medical Corporation·Product code GBK·November 23, 2004

AMPLATZER Delivery System 45-degree curve, order no. 9-DEL-7F-45/80. Product is labeled as Sterile EO. Amplatzer Occluder Device and Delivery System is comprised of delivery sheath, delivery cable, dilator, loading device and pin vise. The Delivery and Exchange Systems are placed onto polyboard backing cards. The backing card is then placed into a smaller of 2 Tyvek pouches. The pouch is then placed inside a larger Tyvek pouch. The kit is assembled at AGA and then sterilized by Steris, Minneapolis, MN.

FDA Recall
Terminated ·AGA Medical Corporation·Product code GBK·November 23, 2004