Status: Terminated
×
Disetronic H-TRONplus Insulin Pump; catalog # 8050023 [clear case], 8050064 [blue case], 8050021 [solid-color case] and 8050071 [yellow case].
FDA Recall
Terminated
·Roche Diagnostics Corp.·Product code LZG·July 21, 2003
ArjoHuntleigh Contoura C1000 series beds are designed to accommodate patients weighing up to 990 lbs. (450 kg). Model C1000 is the basic bed. Model C1080 includes a weighing system and a power outlet for an ArjoHuntleigh approved mattress pump. Product Usage: The Contoura series bariatric beds are electrically operating medical beds with a maximum patient weight of 450 kg. This range is intended for use in hospitals to facilitate management of obese patients. An optional integrated weighing system helps with assessment and management of the patient if required.
FDA Enforcement
Class II
·Terminated·Arjo Hospital Equipment AB·October 15, 2014
Fortify Assura, Sterile EO, Model #/ Part #: CD1257-40/100042322, 100059623; CD1257-40Q/100042341, 100059535; CD1259-40/100041914, 100042338, 100059536, 100059646, 100081567; CD1259-40Q/100041931, 100042339, 100059537, 100059620, 100059626, 100078685; CD1263-40/100042948; CD1263-40Q/100042949; CD1357-40C/100080365, 100080377, 100083441; CD1357-40Q/100080389, 100080390, 100083388; CD1359-40/100078740, 100083267, 100096839; CD1359-40C/100078500, 100078969, 100079372, 100079373, 100083442, 100083443, 100117545; CD1359-40Q/100078804, 100079155, 100079413, 100083445, 100096884; CD1359-40QC/100078603, 100079145, 100079146, 100079239, 100083405, 100083444, 100117632, 100127000, 100127065; CD1363-40C/100080349; CD1363-40Q/100080317; CD1391-40C/100080756; CD1391-40QC/100080783; CD2257-40/100042337, 100059839; CD2257-40Q/100042342, 100059842; CD2259-40/100041893, 100042308, 100059794, 100059907, 100082567; CD2259-40Q/100041894, 100042309, 100059845, 100059873, 100078610; CD2263-40/100042950; CD2263-40Q/100043201; CD2357-40C/100080404, 100080413, 100083490; CD2357-40Q/100080319, 100080412, 100083492; CD2359-40/100078750, 100083466; CD2359-40C/100078651, 100079201, 100079240, 100079442, 100083501, 100083502, 100117546; CD2359-40Q/100078841, 100079109, 100083472; CD2359-40QC/100078652, 100079156, 100079157, 100079337, 100083407, 100083465, 100117580, 100127092, 100127103; CD2363-40C/100080416; CD2363-40Q/100080407; CD2391-40C/100080784; CD2391-40QC/100080744
FDA Enforcement
Class II
·Terminated·St Jude Medical Inc.·July 4, 2018
Boston Scientific COGNIS CRT-D, Cardiac Resynchronization Therapy Defibrillator, models N118, N119. The following models are not available in the US: models N106, N107, P106, P107. Sterilized using ethylene oxide. Product Usage: Boston Scientific cardiac resynchronization therapy defibrillators (CRT-Ds) are indicated for patients with moderate to severe heart failure who remain symptomatic despite stable, optimal heart failure drug therapy and have left ventricular dysfunction and QRS duration > or equal to 120 ms. This family of pulse generators provide a variety of therapies including: -Ventricular tachyarrhythmia therapy, which is used to treat rhythms associated with sudden cardiac death such as VT and VF; -Cardiac Resynchronization Therapy (CRT), which treats heart failure by resynchronizing ventricular contractions through biventricular electrical stimulation; -Bradycardia pacing, including adaptive rate pacing, to detect and treat bradyarrhythmias and to provide cardiac rate support after defibrillation therapy.
FDA Enforcement
Class II