36 results · 9ms · Sources: EU EUDAMED, US FDA

Get notified when this changes

We'll email you when new records match this search — new devices, new clearances, certificate changes, or withdrawals.

Disney Baby Soft Cool Ring Teether Style # Y1470

FDA Recall
Terminated ·RC2 Brands Inc., The First Years·Product code KKO·January 25, 2006

Disney Baby Soft Cool Ring Teether Style # Y1490

FDA Recall
Terminated ·RC2 Brands Inc., The First Years·Product code KKO·January 25, 2006

Sesame Beginnings Chill & Chew Teether Style #Y3095

FDA Recall
Terminated ·RC2 Brands Inc., The First Years·Product code KKO·January 25, 2006

Disney Days Hunny Cool Ring Teether Style # Y1447

FDA Recall
Terminated ·RC2 Brands Inc., The First Years·Product code KKO·January 25, 2006

The First Years Cool Animal Teether/Fish, Zebra and Dinosaur designs Style #Y1473

FDA Recall
Terminated ·RC2 Brands Inc., The First Years·Product code KKO·January 25, 2006

The First Years Floating Friend Teether Style #Y1474

FDA Recall
Terminated ·RC2 Brands Inc., The First Years·Product code KKO·January 25, 2006

MDI Hybrid Implant, O-Ball abutment, sizes 2.9mm x 13mm and 2.9mm x 15mm, endosseous dental implant. The product is used as a endosseous dental implant.

FDA Recall
Terminated ·IMTEC Corporation·Product code KKO·July 7, 2009

Gel Filled Teethers, various shapes and sizes, marketed under the names: Nuby, Cottontails, and Playskool. This product is intended for use by infants for medical purposes to soothe gums during the teething process.

FDA Recall
Terminated ·Luv N' Care Ltd·Product code KKO·July 17, 2009

The EKOS cart has the catalog number 700-60101. The EKOS cart is a custom infusion stand/cart used to hold and transport the EkoSonic Control Unit. The cart is designed with three poles to hold infusion pumps and fluid bags, a tray on which the EkoSonic Control unit sits and a base designed to hold an Uninterruptable Power Supply (UPS). The cart mounts on 4 wheels, two locking and two non-locking.

FDA Recall
Terminated ·EKOS Corporation·Product code FOX·August 22, 2016

The EkoSonic Endovascular System employs high frequency (2-2.5 MHz), low power (0.585 watt average power per transducer) ultrasound to facilitate the delivery of physician-specified fluids in the peripheral vasculature and to deliver solutions into the pulmonary arteries. The EkoSonic Endovascular System is intended for the controlled and selective infusion of physician-specified fluids, including thrombolytics, into the peripheral vasculature and the infusion of solutions into the pulmonary arteries. The reusable EKOS EkoSonic Control Unit provides power to the system and the user interface for operator control. A reusable, non sterile Connector Interface Cable connects the EKOS EkoSonic Control Unit to the EkoSonic Endovascular Device.

FDA Recall
Terminated ·EKOS Corporation·Product code KRA·October 2, 2013

The EKOS cart has the catalog number 700-60101. The EKOS cart is a custom infusion stand/cart used to hold and transport the EkoSonic Control Unit. The cart is designed with three poles to hold infusion pumps and fluid bags, a tray on which the EkoSonic Control unit sits and a base designed to hold an Uninterruptable Power Supply (UPS). The cart mounts on 4 wheels, two locking and two non-locking.

FDA Enforcement
Class II ·Terminated·EKOS Corporation·October 5, 2016

The EKOS EkoSonic Control Unit is intended exclusively for use with the EkoSonic Endovascular Device and the EkoSonic MACH4 Endovascular Device. The EkoSonic Endovascular System consists of three main components: -a single use EkoSonic Endovascular Device which is comprised of an Intelligent Drug Delivery Catheter (IDDC) and -removable MicroSonic Device (MSD), and -a reusable EKOS EkoSonic Control System. During use, fluids are delivered through the side-holes of the IDDC. The MSD is placed through the central lumen of the IDDC to deliver ultrasound energy along the length of fluid delivery, dispersing the fluid into the intravascular treatment site. The reusable EKOS EkoSonic Control Unit provides power to the system and the user interface for operator control. A reusable, nonsterile Connector Interface Cable connects the EKOS EkoSonic Control Unit to the EkoSonic Endovascular Device.

FDA Recall
Terminated ·EKOS Corporation·Product code KRA·June 24, 2015

Lysus Infusion System - Lysus Drug Delivery Catheter: The Lysus Infusion System employs high frequency (2-2.5 MHz), low power (0.45 watt average power per transducer) ultrasound to facilitate the delivery of physician-specified fluids in the peripheral vasculature. (This system is also called the UltraFlo and EKOS Peripheral Infusion System in internal documents.) The Lysus Infusion System consists of three main components, a single use Lysus Infusion Catheter System which is comprised of a Drug Delivery Catheter (DDC) and removable Ultrasound Core (USC), and a reusable EKOS PT-3 Control System. During use, fluids are delivered through the side-holes of the DDC. The USC is placed through the central lumen of the DDC to deliver ultrasound energy along the length of fluid delivery, dispersing the fluid into the intravascular treatment site. The reusable EKOS PT-3 Control Unit provides power to the system and the user interface for operator control. A reusable, non-sterile Catheter Interface Cable with Pod connects the EKOS PT-3 Control Unit to the Lysus Infusion Catheter System.

FDA Recall
Terminated ·Ekos Corp·Product code KRA·November 22, 2004

The EKOS EkoSonic Control Unit is intended exclusively for use with the EkoSonic Endovascular Device and the EkoSonic MACH4 Endovascular Device. The EkoSonic Endovascular System consists of three main components: -a single use EkoSonic Endovascular Device which is comprised of an Intelligent Drug Delivery Catheter (IDDC) and -removable MicroSonic Device (MSD), and -a reusable EKOS EkoSonic Control System. During use, fluids are delivered through the side-holes of the IDDC. The MSD is placed through the central lumen of the IDDC to deliver ultrasound energy along the length of fluid delivery, dispersing the fluid into the intravascular treatment site. The reusable EKOS EkoSonic Control Unit provides power to the system and the user interface for operator control. A reusable, nonsterile Connector Interface Cable connects the EKOS EkoSonic Control Unit to the EkoSonic Endovascular Device.

FDA Enforcement
Class II ·Terminated·EKOS Corporation·July 29, 2015

EkoSonic Endovascular System, Catalog Number 500-56112. It consists of three main components, a single use EkoSonic Endovascular Device which is comprised of an Intelligent Drug Delivery Catheter (IDDC) and removable MicroSonic Device (MSD), and a reusable EKOS EkoSonic Control System. During use, fluids are delivered through the side-holes of the IDDC. The MSD is placed through the central lumen of the IDDC to deliver ultrasound energy along the length of fluid delivery, dispersing the fluid into the intravascular treatment site. The reusable EKOS EkoSonic Control Unit provides power to the system and the user interface for operator control. A reusable, non-sterile Connector Interface Cable connects the EKOS EkoSonic Control Unit to the EkoSonic Endovascular Device.

FDA Enforcement
Class II ·Terminated·EKOS Corporation·March 2, 2016

EkoSonic MACH4 Endovascular Device (Catalog #500-55106, 500-55112; 500-55118; 500-55124; 500-55130; 500-55140; 500-55150; 500-54106; 500-56130; 500-56140; 500-56150) is a catheter, continuous infusion. it consists of the Intelligent Drug Delivery Catheter (IDDC) and the MicroSonic Device (MSD). It is intended for the controlled and selective infusion of physician-specific fluids, including thrombolytics, into the peripheral vasculature. All therapeutic agents utilized with the EkoSonic Endovascular System should be fully prepared and used according to the instruction for use of the specific therapeutic agent. The Kit MACH4 is labeled in parts: "***EkoSonic MACH4 Endovascular Device***MicroSonic Device and Intelligent Drug Delivery Catheter***". The Pouch MSD is labeled in parts: "***EKOS***MicroSonic Device***Sterile***". EkoSonic Endovascular System is a catheter, continuous infusion. It is intended for the controlled and selective infusion of physician-specific fluids, including thrombolytics, into the peripheral vasculature. The system is also intended for the infusion of solutions into pulmonary arteries.

FDA Recall
Terminated ·EKOS Corporation·Product code KRA·May 24, 2012

The Lysus Infusion System - Catheter Interface Cable. The Lysus Infusion System employs high frequency (2-2.5 MHz), low power (0.45 watt average power per transducer) ultrasound to facilitate the delivery of physician-specified fluids in the peripheral vasculature. (This system is also called the UltraFlo and EKOS Peripheral Infusion System in internal documents.) The Lysus Infusion System consists of three main components, a single use Lysus Infusion Catheter System which is comprised of a Drug Delivery Catheter (DDC) and removable Ultrasound Core (USC), and a reusable EKOS PT-3 Control System. During use, fluids are delivered through the side-holes of the DDC. The USC is placed through the central lumen of the DDC to deliver ultrasound energy along the length of fluid delivery, dispersing the fluid into the intravascular treatment site. The reusable EKOS PT-3 Control Unit provides power to the system and the user interface for operator control. A reusable, non-sterile Catheter Interface Cable with Pod connects the EKOS PT-3 Control Unit to the Lysus Infusion Catheter System.

FDA Recall
Terminated ·Ekos Corp·Product code KRA·September 21, 2004

Lysus Infusion System - PT-3 Control . The Lysus Infusion System employs high frequency (2-2.5 MHz), low power (0.45 watt average power per transducer) ultrasound to facilitate the delivery of physician-specified fluids in the peripheral vasculature. (This system is also called the UltraFlo and EKOS Peripheral Infusion System in internal documents.) The Lysus Infusion System consists of three main components, a single use Lysus Infusion Catheter System which is comprised of a Drug Delivery Catheter (DDC) and removable Ultrasound Core (USC), and a reusable EKOS PT-3 Control System. During use, fluids are delivered through the side-holes of the DDC. The USC is placed through the central lumen of the DDC to deliver ultrasound energy along the length of fluid delivery, dispersing the fluid into the intravascular treatment site. The reusable EKOS PT-3 Control Unit provides power to the system and the user interface for operator control. A reusable, non-sterile Catheter Interface Cable with Pod connects the EKOS PT-3 Control Unit to the Lysus Infusion Catheter System.

FDA Recall
Terminated ·Ekos Corp·Product code KRA·January 18, 2005

EkoSonic Endovascular System, Catalog Number 500-56112. It consists of three main components, a single use EkoSonic Endovascular Device which is comprised of an Intelligent Drug Delivery Catheter (IDDC) and removable MicroSonic Device (MSD), and a reusable EKOS EkoSonic Control System. During use, fluids are delivered through the side-holes of the IDDC. The MSD is placed through the central lumen of the IDDC to deliver ultrasound energy along the length of fluid delivery, dispersing the fluid into the intravascular treatment site. The reusable EKOS EkoSonic Control Unit provides power to the system and the user interface for operator control. A reusable, non-sterile Connector Interface Cable connects the EKOS EkoSonic Control Unit to the EkoSonic Endovascular Device.

FDA Recall
Terminated ·EKOS Corporation·Product code KRA·January 21, 2016

EKOS EndoWave Infusion System and EKOS Lysus Infusion Systems - drug delivery catheters. EKOS Corporation Bothell, WA Packaging: *EndoWave(TM) Ultrasound Accelerated Thrombolysis (USAT) EKOS EndoWave Infusion System Drug Delivery Catheter with Ultrasound Core. and ''Lysus Infusion System''. EndoWave Infusion Systems 06, 2.7W, part #4599-001, catalog #500-52106; Systems 12, 2.7W, part #4599-002, catalog 500-52112; Systems 18, 2.7W, part #4599-003, catalog #500-52118; Systems 24, 2.7W, part #4599-004, catalog #500-52124; Systems 30, 2.7W, part #4599-005, catalog #500-52130; Systems 40, 2.7W, part 4599-006, catalog #500-52140; Systems 50, 2.7W, part #4599-007, catalog #500-52150; Systems 06, 3.5W, part #5199-001, catalog #500-54106; Systems 12, 3.5W, part #5199-002, catalog #500-54112; Systems 18, 3.5W, part #5199-003, catalog #500-54118; Systems 24, 3.5W, part #5199-004, catalog #500-54124; Systems 30, 3.5W, part #5199-005, catalog #500-54130, Systems 40, 3.5W, part #5199-006, catalog #500-54140; Systems 50, 3.5W, part #5199-007, catalog #500-54150; Lysus Infusion Systems 06, 2.7W, part #4599-001, catalog 500-52106; Systems 12, 2.7W, part #4599-002, catalog 500-52112; Systems 18, 2.7W, part #4599-003, catalog #50-52118; Systems 24, 2.7W, part #4599-004, catalog #500-52124; Systems 30, 2.7W, part #4599-005, catalog #500-52130; Systems 40, 2.7W, part #4599-006, catalog #500-52140; Systems 50, 2.7W, part #4599-007, catalog #500-52150; Systems 06, 3.5W, part #5199-001, catalog 500-54106; Systems 12, 3.5W, part #5199-002, catalog #500-54112; Systems 18, 3.5W, part #5199-003, 500-54118; Systems 24, 3.5W, part #5199-004, catalog #500-54124; Systems 30, 3.5W, part #5199-005, catalog #500-54130; Systems 40, 3.5W, part #5199-005, catalog #500-54140; Systems 50, 3.5W, part #5199-007, catalog #500-54150

FDA Recall
Terminated ·Ekos Corp·Product code KRA·February 9, 2007