LPS-FLEX OPTION FEMORAL C-L LPS-FLEX OPTION FEMORAL C-L LPS-FLEX OPTION FEMORAL C-R LPS-FLEX OPTION FEMORAL D-L LPS-FLEX OPTION FEMORAL D-R LPS-FLEX OPTION FEMORAL E-L LPS-FLEX OPTION FEMORAL E-R LPS-FLEX OPTION FEMORAL F-L LPS-FLEX OPTION FEMORAL F-R LPS-FLEX OPTION FEMORAL G-L LPS-FLEX OPTION FEMORAL G-R This device is indicated for patients with severe knee pain and disability
FDA Enforcement
Class II
·Terminated·Zimmer Biomet, Inc.·March 21, 2018
Zimmer NexGen Complete Knee Solution Legacy Knee- Posterior Stabilized LPS-FLEX Femoral Component Option Size G Left , sterile, Zimmer, Warsaw, IN; REF 00-5964-017-51.
FDA Recall
Terminated
·Zimmer Inc.·Product code NJL·April 17, 2009
NexGen LPS Femoral Component, Left and Right, Size G Replaces the femoral condyle of the knee joint in Total Knee Arthroplasty.
FDA Enforcement
Class II
·Terminated·ZIMMER ORTHOPEDIC MFG LTD·February 28, 2018
NexGen LPS Flex Option Femoral NexGen LPS Flex Precoat Femoral prosthesis, knee, patellofemorotibial, semi-constrained, metal/polymer, mobile bearing various sizes "" This device is indicated for patients with severe knee pain and disability due to: Rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis. Collagen disorders, and/or avascular necrosis of the femoral condyle. Post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy. Moderate valgus, varus, or flexion deformities. The salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery. " CR-Flex and LPS-Flex porous coated femoral and tibial baseplate components may be used cemented or uncemented (biological fixation). CR-Flex HA/TCP porous coated femoral and tibial baseplate components may only be used uncemented. All other femoral, tibial baseplate and all-polyethylene patella components are indicated for cemented use only. " Specific uses with CR-Flex or LPS-Flex femorals: Provides increased flexion capability for patients who have both the flexibility and desire to increase their flexion range. The CR-Flex femoral, when used with 90-prefix NexGen CR articular surfaces, 00-prefix 10, 12 or 14 mm or 90-prefix 17 or 20 mm Prolong¿ Highly Crosslinked Polyethylene CR articular surfaces, is designed for use with a functional posterior cruciate ligament and when load bearing range of motion (ROM) is expected to be less than or equal to 155 degrees. The LPS-Flex femoral, when used with the LPS-Flex articular surfaces, is designed for use with both cruciate ligaments excised and when load bearing ROM is expected to be less than or equal to 155 degrees. " Specific Uses with NexGen LPS or LCCK femorals: The LPS femoral is designed for use with both cruciate ligaments excised and when load bearing ROM is expected to be less than or equal to 130 degrees. The usage of the LCCK femoral is the same as the LPS with the exception that femoral bone loss can be accommodated by femoral stem extensions and augmentation. No varus/valgus constraint or other stability other than that provided by the NexGen LPS is provided when the LCCK femoral component is used with the LPS-Flex articular surfaces."
FDA Enforcement
Class II
·Terminated·Zimmer Biomet, Inc.·March 2, 2016
NexGen LPS-FLEX Option Femoral NexGen LPS-FLEX Precoat Femoral prosthesis, knee, patellofemorotibial, semi-constrained, cemented, polymer/metal/polymer various sizes Product Usage "" This device is indicated for patients with severe knee pain and disability due to: Rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis. Collagen disorders, and/or avascular necrosis of the femoral condyle. Post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy. Moderate valgus, varus, or flexion deformities. The salvage of previously failed surgical attempts or for a knee in which satisfactory stability in flexion cannot be obtained at the time of surgery. " CR-Flex and LPS-Flex porous coated femoral and tibial baseplate components may be used cemented or uncemented (biological fixation). CR-Flex HA/TCP porous coated femoral and tibial baseplate components may only be used uncemented. All other femoral, tibial baseplate and all-polyethylene patella components are indicated for cemented use only. " Specific uses with CR-Flex or LPS-Flex femorals: Provides increased flexion capability for patients who have both the flexibility and desire to increase their flexion range. The CR-Flex femoral, when used with 90-prefix NexGen CR articular surfaces, 00-prefix 10, 12 or 14 mm or 90-prefix 17 or 20 mm Prolong¿ Highly Crosslinked Polyethylene CR articular surfaces, is designed for use with a functional posterior cruciate ligament and when load bearing range of motion (ROM) is expected to be less than or equal to 155 degrees. The LPS-Flex femoral, when used with the LPS-Flex articular surfaces, is designed for use with both cruciate ligaments excised and when load bearing ROM is expected to be less than or equal to 155 degrees. " Specific Uses with NexGen LPS or LCCK femorals: The LPS femoral is designed for use with both cruciate ligaments excised and when load bearing ROM is expected to be less than or equal to 130 degrees. The usage of the LCCK femoral is the same as the LPS with the exception that femoral bone loss can be accommodated by femoral stem extensions and augmentation. No varus/valgus constraint or other stability other than that provided by the NexGen LPS is provided when the LCCK femoral component is used with the LPS-Flex articular surfaces."
FDA Enforcement
Class II
·Terminated·Zimmer Biomet, Inc.·March 2, 2016
Reamer / Irrigator / Aspirator (RIA): RIA Drive Shafts, RIA Tube Assemblies, sterile, RIA Reamer Head, sterile (12.0mm-19.0mm); intended to clear the medullary canal of bone marrow and debris and to effectively size the medullary canal for the acceptance of an intramedullary implant or prosthesis
FDA Enforcement
Class II
·Terminated·Synthes, Inc.·July 22, 2015