Mercury Spinal System DIA 5.5 x 110mm Straight Rod, Part Number: 60101-110. Intended to provide immobilization and stabilization of the spine in skeletally mature patients.
FDA Enforcement
Class III
·Terminated·Spinal Elements, Inc·May 15, 2013
DURAMAX (TM) Hemodialysis Catheters, Stacked Tip 28 cm Straight Basic Kit, Catalog Number/REF 10302804, 510 (k) 080400, Sterile --- Manufactured in USA by AngioDynamics, Inc. 603 Queensbury Avenue, Queensbury, NY 12804
FDA Recall
Terminated
·Angiodynamics, Inc.·Product code MSD·January 8, 2010
DURAMAX (TM) Hemodialysis Catheters, Stacked Tip 40 cm Straight Basic Kit, Catalog Number/REF 10302807, 510 (k) 080400, Sterile --- Manufactured in USA by AngioDynamics, Inc. 603 Queensbury Avenue, Queensbury, NY 12804
FDA Recall
Terminated
·Angiodynamics, Inc.·Product code MSD·January 8, 2010
DURAMAX (TM) Hemodialysis Catheters, Stacked Tip 24 cm Straight Basic Kit, Catalog Number/REF 10302803, 510 (k) 080400, Sterile --- Manufactured in USA by AngioDynamics, Inc. 603 Queensbury Avenue, Queensbury, NY 12804
FDA Recall
Terminated
·Angiodynamics, Inc.·Product code MSD·January 8, 2010
DURAMAX (TM) Hemodialysis Catheters, Stacked Tip 22 cm Straight Basic Kit, Catalog Number/REF 10302802, 510 (k) 080400, Sterile --- Manufactured in USA by AngioDynamics, Inc. 603 Queensbury Avenue, Queensbury, NY 12804
FDA Recall
Terminated
·Angiodynamics, Inc.·Product code MSD·January 8, 2010
DURAMAX (TM) Hemodialysis Catheters, Stacked Tip 32 cm Straight Basic Kit, Catalog Number/REF 10302805, 510 (k) 080400, Sterile --- Manufactured in USA by AngioDynamics, Inc. 603 Queensbury Avenue, Queensbury, NY 12804
FDA Recall
Terminated
·Angiodynamics, Inc.·Product code MSD·January 8, 2010
DURAMAX (TM) Hemodialysis Catheters, Stacked Tip 36 cm Straight Basic Kit, Catalog Number/REF 10302806, 510 (k) 080400, Sterile --- Manufactured in USA by AngioDynamics, Inc. 603 Queensbury Avenue, Queensbury, NY 12804
FDA Recall
Terminated
·Angiodynamics, Inc.·Product code MSD·January 8, 2010
DURAMAX (TM) Hemodialysis Catheters, Stacked Tip 55 cm Straight Basic Kit, Catalog Number/REF 10302809, 510 (k) 080400, Sterile --- Manufactured in USA by AngioDynamics, Inc. 603 Queensbury Avenue, Queensbury, NY 12804
FDA Recall
Terminated
·Angiodynamics, Inc.·Product code MSD·January 8, 2010
DURAMAX (TM) Hemodialysis Catheters, Stack Tip 28 cm Pre-Curve Basic Kit, Catalog Number/REF 10302813, 510 (k) 080400, Sterile --- Manufactured in USA by AngioDynamics, Inc. 603 Queensbury Avenue, Queensbury, NY 12804
FDA Recall
Terminated
·Angiodynamics, Inc.·Product code MSD·January 8, 2010
DURAMAX (TM) Hemodialysis Catheters, Stack Tip 32 cm Pre-Curve Basic Kit, Catalog Number/REF 10302814, 510 (k) 080400, Sterile --- Manufactured in USA by AngioDynamics, Inc. 603 Queensbury Avenue, Queensbury, NY 12804
FDA Recall
Terminated
·Angiodynamics, Inc.·Product code MSD·January 8, 2010
DURAMAX (TM) Hemodialysis Catheters, Stack Tip 24 cm Pre-Curve Basic Kit, Catalog Number/REF 10302812, 510 (k) 080400, Sterile --- Manufactured in USA by AngioDynamics, Inc. 603 Queensbury Avenue, Queensbury, NY 12804
FDA Recall
Terminated
·Angiodynamics, Inc.·Product code MSD·January 8, 2010
DURAMAX (TM) Hemodialysis Catheters, Stack Tip 36 cm Pre-Curve Basic Kit, Catalog Number/REF 10302815, 510 (k) 080400, Sterile --- Manufactured in USA by AngioDynamics, Inc. 603 Queensbury Avenue, Queensbury, NY 12804
FDA Recall
Terminated
·Angiodynamics, Inc.·Product code MSD·January 8, 2010
Manta Ray: Anterior Cervical Plate (ACP) System, 510 (k) #K080690. The labeling for the plate component reads in part: 'REF: 22-'**** MAT'L: Titanium per ASTM F-136, Lot: W****, Description: Plate - 40 mm, Qty: 1.' The labeling for the screw component reads in part: 'REF: 22-**** MAT'L: Titanium per ASTM F-136 LOT W**** Description: Screw-Fixed Tapping 4x10mm QTY: 1. Manta Ray Anterior Cervical Plate (ACP) System is intended for temporary stabilization of the cervical spine C2-C7 due to the following indications: DDD (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies); Spondylolisthesis; Trauma (i.e. fracture/dislocation); Tumor; Spinal stenosis; Deformity (i. e. scoliosis, kyphosis and/or lordosis); Pseudoarthrosis; and Failed previous fusion.
FDA Recall
Terminated
·Theken Spine Llc·Product code KWQ·July 29, 2010
Marathon Flow Directed Micro Catheter, UltraFlow HPC Flow Directed Micro Catheter Marathon Flow: The device is intended to access periphera and neurovasculature for the controlled selective infusion of physician-specified therapeutics agents such as embolization materials and of diagnostic materials such as contrast media. UltraFlow HPC Flow: The device is intended for the controlled selective infusion of physician-specified pharmacologic agents or contrast media into the distal vasculature of the peripheral and neuroanatomy. It is not intended for use in the coronary vasculature. Catalog No. 105-5055V02 105-5055V02 105-5055V05 105-5065V02 105-5065V05 105-5066V02 105-5066V05
FDA Enforcement
Class I
·Terminated·Micro Therapeutics Inc, Dba Ev3 Neurovascular·November 16, 2016
Quadra Assura MP, Sterile EO, Model #/ Part #: CD3269-40/100043177; CD3269-40Q/100043178; CD3271-40/100043130; CD3271-40Q/100043191; CD3369-40C/100080339, 100080478; CD3369-40Q/100080439, 100080476, 100105528; CD3371-40/100078814, 100079232, 100079513; CD3371-40C/100078639, 100079231, 100079478, 100105493, 100105494; CD3371-40Q/100078815,100079282, 100079479, 100138237; CD3371-40QC/100078640, 100079165, 100079506, 100079541, 100105505, 100105506, 100138173, 100138179, 100138222, 100138234; CD3387-40C/100105525; CD3387-40QC/100138158
FDA Enforcement
Class II
·Terminated·St Jude Medical Inc.·July 4, 2018