Ethicon Endo-Surgery Endopath ETS-Flex Articulating Endoscopic Linear Cutter, 35mm Standard, Product #ATB35.

FDA Recall
Terminated ·Ethicon Endo-Surgery·Product code GDW·November 25, 2003

Endopath EZ45 Endoscopic Linear Cutter (ET45B).

FDA Recall
Terminated ·Ethicon Endo-Surgery·Product code GDW·November 21, 2004

Intelligent 60mm Articulating Endoscopic Linear Cutter, product code i60; Intelligent 60mm Articulating Endoscopic Linear Cutter Extra Long, product code i60XXL; Intelligent 45mm Articulating Endoscopic Linear Cutter, product code i45; Intelligent 45mm Articulating Endoscopic Linear Cutter, Vascular, product code i45V.

FDA Recall
Terminated ·Surgical Devices/Covidien·Product code GDW·September 23, 2009

Intelligent 60mm Straight Endoscopic Linear Cutter, product code i60S; Intelligent 60mm Straight Endoscopic Linear Cutter Reconditioned, product code i60SRC.

FDA Recall
Terminated ·Surgical Devices/Covidien·Product code GDW·September 23, 2009

Straight Linear Cutter 55 mm Blue Digital Loading Unit, product code SLC55B; Straight Linear Cutter 55 mm Green Digital Loading Unit, product code SLC55G; Straight Linear Cutter 55 mm Blue Reload, product code SLCR55B; Straight Linear Cutter 55 mm Green Reload, product code SLCR55G; Straight Linear 4 Row No Knife Digital Loading Unit, product code SLS55B4.

FDA Recall
Terminated ·Surgical Devices/Covidien·Product code GDW·September 23, 2009

Covidien Duet TRS 45 3.5 mm Universal Straight Single Use Loading Unit. Product Code: DUET4535. Single Use Loading Unit (SULU) tissue reinforcement stapler. The Endo GIA Universal Staplers with Duet TRS reloads have applications in abdominal, gynecologic and pediatric surgery for resection, transection and creation of anastomoses. They may be used for transection and resection of liver substance, hepatic vasculature and biliary structures and for transection and resection of pancreas.

FDA Recall
Terminated ·Product code GDW·August 21, 2012

Auto SutureTA 45 Reloadable Stapler,Single Patient Use, 3.5mm DST Series Ref: TA4535S

FDA Recall
Terminated ·United States Surgical·Product code GDW·May 5, 2004

Auto SutureTA 30 Reloadable Stapler,Single Patient Use,3.5mm DST Series Ref: TA3035S

FDA Recall
Terminated ·United States Surgical·Product code GDW·May 5, 2004

Davol Salut Fixation Reusable 38cm Shaft (Laparoscopic) Item Numbers: 0113036-Product Code 9113036-(Refurbished)

FDA Recall
Terminated ·Davol, Inc., Sub. C. R. Bard, Inc.·Product code GDW·July 16, 2007

Power Linear Cutter Reusable Digital Loading Units with Reloads. Common name - Implantable staple. Model number PLC60

FDA Recall
Terminated ·Power Medical Interventions, Inc·Product code GDW·May 12, 2007

DUET TRS 60 4.8MM ARTICULATING SULU Product Code: DUET6048A Product Usage: The ENDO GIA UNIVERSAL Staplers with Duet TRS SULUs have applications in abdominal, gynecologic, pediatric and thoracic surgery for resection, transection and creation of anastomosis. They may be used for transection and resection of liver substance, hepatic vasculature and biliary structures. When used with the ENDO GIA Universal and Ultra Staplers, the Duet TRS Reloads with Biosyn tissue reinforcement place two, triple-staggered rows titanium staples while simultaneously dividing the tissue and anchoring the preloaded Biosyn reinforcement material. The preloaded reinforcement material Is fully detached from the SULU upon complete firing of the length of the cartridge. The Duet TRS reinforcement material (Biosyn) Is a synthetic absorbable film prepared from synthetic polyester composed of glycolide, dioxanone, and trimethylene carbonate.

FDA Recall
Terminated ·Product code GDW·January 12, 2012

Covidien Endo GIA Ultra Universal Standard Stapler Handle Ref: EGIAUSTND Product Usage: The Endo GIA Ultra Universal Short, Endo GIA Ultra Universal and Endo GIA Ultra Universal XL staplers have applications in abdominal, gynecologic, pediatric and thoracic surgery for resection, transection and creation of anastomosis. It may be used for transection and resection of liver substance, hepatic vasculature and biliary structures. The Endo GIA Ultra Universal Short, Endo GIA Ultra Universal and Endo GIA Ultra Universal XL staplers when used with the Endo GIA curved tip single use reloads can be used to blunt dissect or separate target tissue from other tissue.

FDA Recall
Terminated ·Medtronic·Product code GDW·December 2, 2015

Covidien Signia Small Diameter Curved Tip Intelligent Reload 45 mm Vascular/Thin 8 mm - Long Item Code: SIGSDL45CTVT

FDA Recall
Terminated ·Product code GDW·March 4, 2021

Disposable Curved Circular Staplers Product Usage: Staplers have application throughout the alimentary tract for end-to-end, end-to-side, and side-to-side anastomoses.

FDA Recall
Terminated ·Ethicon Endo-Surgery Inc·Product code GDW·October 23, 2017

(1)BOX PST01199 BARIATRIC TRISTAPLE (Item Number: PST01199) (2) BOX PST03403 ALTERNATIVE APPENDIX KIT (Item Number: PST03403) (3) BOX PST03533 KIT APP STAPLER (Item Number: PST03403) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples is determined by the selection of the 2.0 mm, 2.5 mm, 3.5 mm or 4.8 mm single use loading unit. The Endo GIA universal staplers will accommodate any of the single use loading unit sizes that are available in the 30 mm, 45 mm and 60 mm lines.

FDA Recall
Terminated ·COVIDIEN MEDTRONIC·Product code GDW·April 26, 2018

BOX LAPIMBGP1 ZESTAW DO MGBP (LAPIMBGP1) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples is determined by the selection of the 2.0 mm, 2.5 mm, 3.5 mm or 4.8 mm single use loading unit. The Endo GIA universal staplers will accommodate any of the single use loading unit sizes that are available in the 30 mm, 45 mm and 60 mm lines.

FDA Recall
Terminated ·COVIDIEN MEDTRONIC·Product code GDW·April 26, 2018

BOX VWR ZESTAW DO VATS KLIN Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples is determined by the selection of the 2.0 mm, 2.5 mm, 3.5 mm or 4.8 mm single use loading unit. The Endo GIA universal staplers will accommodate any of the single use loading unit sizes that are available in the 30 mm, 45 mm and 60 mm lines.

FDA Recall
Terminated ·COVIDIEN MEDTRONIC·Product code GDW·April 26, 2018

(1)BOX KITDE0183 APPENDIX LIPPE DETMOLD (KITDE0183) (2) KIT-DE-0083 APPENEKTOMIE KIT NAUENX1 (Item Number: KIT-DE-0083,KIT-DE-0083 APPENEKTOMIE KIT NAUENX1 Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples is determined by the selection of the 2.0 mm, 2.5 mm, 3.5 mm or 4.8 mm single use loading unit. The Endo GIA universal staplers will accommodate any of the single use loading unit sizes that are available in the 30 mm, 45 mm and 60 mm lines.

FDA Recall
Terminated ·COVIDIEN MEDTRONIC·Product code GDW·April 26, 2018

Signia" Power Handle (SIGPHANDLE, SIGNVAL1 and SIGVAL20 - Kits) The Signia" Power Handle, when used with Endo GIA" single-use reloads and Endo GIA" single-use reloads with Tri-Staple" Technology, has applications in open and minimally invasive general abdominal, gynecological, pediatric, and thoracic surgery for resection, transection, and creation of anastomosis.

FDA Recall
Terminated ·Covidien LLC·Product code GDW·December 13, 2017

EEA" Hemorrhoid and Prolapse Stapler Set with DST Series" Technology 3.5MM, Product Number HEM3335, GTIN Number 1 - 10884521047518, GTIN Number 2 - 20884521047515 Product Usage: The EEA Hemorrhoid and prolapse stapler set with DST Series Technology (instrument) is designed for use as a stapler instrument for control of rectal prolapse and hemorrhoid disease. The instrument places a circular, double-staggered row of titanium DST staples and removes a circular tissue specimen. The instrument is offered in a 33mm diameter size with either 3.5mm or 4.8mm staples. The accompanying accessories comprised of an access port, anoscope, and dilator. The access port aids the insertion and removal of the anoscope and the stapler device by dilating the anal sphincter throughout the procedure. The anoscope is designed to facilitate pursestring suture application above the dentate line. It is designed with a guide and markings to assist in creating a circumferential pursestring suture at a consistent placement within the rectum. The dilator is designed to aid the initial insertion of the anoscope and port by retracting the rectal tissue. Both the anoscope and port are transparent to facilitate visualization of the anal canal. The EEA Hemorrhoid and prolapse stapler set with DST Series Technology has application throughout the anal canal to perform surgical treatment of hemorrhoidal disease. The EEA Hemorrhoid and prolapse stapler also has application in the distal alimentary tract for the creation of end-to-end and end-to-side anastomoses.

FDA Recall
Terminated ·Covidien LLC·Product code GDW·April 9, 2018