20 results
·
20ms
·
Sources: EU EUDAMED, US FDA
Filters
Regulation: Us FDA
×
Purzir Dental Zirconia
FDA 510(k)
FDA Class 2
·Dental
Sklar®
FDA UDI
SKLAR CORPORATION·10649111027819·WILLIAMS STIEGLITZ FCP ANG 5.5
IN-OVATION® Mini
FDA UDI
DENTSPLY SIRONA ORTHODONTICS INC.·D807K19105514R1·IN-OVATION® mini Rhodium Base Rx 018 UL/5-5 CS ...
N/A
FDA UDI
DENTSPLY SIRONA ORTHODONTICS INC.·D807K190055001·MTM® NO TRACE (TM) 018 UL/4-4
IN-OVATION® Mini
FDA UDI
DENTSPLY SIRONA ORTHODONTICS INC.·D807K191055241·IN-OVATION® mini Base Rx 022 UL/5-5 CS BC HK
IN-OVATION® Mini
FDA UDI
DENTSPLY SIRONA ORTHODONTICS INC.·D807K19105523P1·IN-OVATION®mini Base Rx 022 UL/5-5 CS HK PSV
IN-OVATION® L
FDA UDI
DENTSPLY SIRONA ORTHODONTICS INC.·D807K190055011·IN-OVATION® L 018 UPPER 6-6
IN-OVATION® Mini
FDA UDI
DENTSPLY SIRONA ORTHODONTICS INC.·D807K191055131·IN-OVATION® mini Base Rx 018 UL/5-5 CS HK
IN-OVATION® Mini
FDA UDI
DENTSPLY SIRONA ORTHODONTICS INC.·D807K19105523R1·IN-OVATION®mini Rhodium Base Rx 022 UL/5-5 CS HK
IN-OVATION® Mini
FDA UDI
DENTSPLY SIRONA ORTHODONTICS INC.·D807K191055231·IN-OVATION®mini Base Rx 022 UL/5-5 CS HK
IN-OVATION® L
FDA UDI
DENTSPLY SIRONA ORTHODONTICS INC.·D807K190055101·IN-OVATION® L 018 UL/7-7
IN-OVATION® Mini
FDA UDI
DENTSPLY SIRONA ORTHODONTICS INC.·D807K19105524R1·IN-OVATION®mini Rhodium Base Rx 022 UL/5-5 CS B...
SMITH & NEPHEW, INC SCREW AND PLATE SYSTEM INSTRUMENTATION
FDA 510(k)
FDA Class 2
·Orthopedic
CSTS SCREW
FDA 510(k)
FDA Class 2
·Orthopedic
ARTICULEZE M HEAD 36MM -2
FDA Adverse Event
Injury
·DEPUY ORTHOPAEDICS INC US·Product code JDI·June 27, 2013
9900
FDA Adverse Event
Malfunction
·GE OEC MEDICAL SYSTEMS (SLC)·Product code JAA·July 22, 2011
PARADIGM REAL-TIME INSULIN INFUSION PUMP
FDA Adverse Event
Malfunction
·MEDTRONIC PUERTO RICO OPERATIONS CO.·Product code OYC·October 22, 2014
NEXTAR INFRARED CAMERA
FDA Adverse Event
Malfunction
·MEDACTA INTERNATIONAL SA·Product code JWH·September 10, 2021
BD Nexiva, 20 GA 1.00 IN (1.1 X 25 mm), 3660 ml/hr. 61ml/min; Closed IV Catheter System- Dual port -61 mL/min (3660 mL/hr)-0.5mL, REF 383536; BD Q-Style Luer Access Split Septum BD Vialon Material; BD Instaflash Needle Technology; Rx Only, Sterile EO. BD Nexiva closed IV catheter systems are over-the-needle, intravascular catheters. These devices have a radiopaque BD Vialon" catheter, needle, needle shield, septum, stabilization platform, integrated extension tubing, clamp, dual port adapter, vent plug and pre-attached BD Q-Syte Luer Access Split Septum. The needle and catheter are protected by a needle cover. A BD Q-Syte device or an end cap with protective cover is provided in the unit package. The closed system is designed to keep blood contained within the device throughout the insertion process. The septum is designed to wipe visible blood from the needle surface as the needle is withdrawn from the catheter, further reducing the risk of blood exposure. The needle tip is passively protected when the needle is removed, reducing the risk of accidental needlestick injury. These devices have BD Instaflash" Needle Technology, allowing for immediate visualization of blood along the catheter. Continuous blood return is seen in the extension tubing. The vent plug prevents blood leakage from the extension tubing during insertion. Both the stabilization platform and dual port adapter are color coded to indicate catheter gauge size (24GA (0.7 mm)=Yellow, 22GA (0.9 mm)=Blue, 20GA (1.1 mm)=Pink, 18GA (1.3 mm)=Green). BD Nexiva closed IV catheter systems are intended to be inserted into a patient s vascular system for short term use to sample blood, monitor blood pressure, or administer fluids. These catheters may be used for any patient population with consideration given to adequacy of vascular anatomy, procedure being performed, fluids being infused, and duration of therapy. The 22-18GA (0.9-1.3 mm) devices are suitable for use with power injectors set to a maximum pressure of 300 psi (2068 kPa) when access ports not suitable for use with power injectors are removed.
FDA Enforcement
Class II
·Ongoing·Becton Dickinson Infusion Therapy Systems Inc.·December 1, 2021
Battery Operated infusion pumps. t:slim X2 G5, Replacement, Refurbished, REF: 1000911; t:slim X2 GS Classic, Replacement, Refurbished, REF: 1003808; t: slim X2, Basal-IQ, mg/dl, REF: 1004219; Pump, t:slim X2, Clinical Use Only, REF: 1004484; Pump, t:slim X2, Control-IQ, REF: 1005611; Pump, t:slim X2, Control-IQ, mmoUL, Refurbished Replacement, REF: 1005613; Pump, t:slim X2, Control-IQ, mg/dl, REF: 1005615; Pump, t:slim X2, Control-IQ, mg/dl, Refurbished Replacement, REF: 1005617; Pump, t:slim X2, Basal-IQ 6.4, Refurbished Replacement, REF: 1006379; Pump, t:slim X2, Control-IQ 7.4, REF: 1006402; Pump, t:slim X2, Control-IQ 7.4, Replacement, REF: 1006406; Pump, t:slim X2, Control-IQ 7.4, REF: 1006408; Pump, t:slim X2, Basal-IQ, , REF: 1006419; Pump, t:slim X2, Basal-IQ, mg/dL, REF: 1006420; Pump, t:slim X2, Basal-IQ, mmoUL, Refurbished Replacement, REF: 1006535; Pump, t:slim X2, Basal-IQ, mg/dL, Refurbished Replacement, REF: 1006537; Pump, t:slim X2, Control-IQ, mg/dl , Replacement, REF: 1008255; Pump, t:slim X2, Control-IQ, mmoUL, Replacement, REF: 1008256; Pump, t:slim X2, Basal-IQ, mmoUL, Replacement, REF: 1008257; Pump, t:slim X2, Basal-IQ, mg/dl ,Replacement, REF: 1008258; Pump, t:slim X2, Basal-IQ, REF: 1010004; Pump, t:slim X2, Basal-IQ, Replacement, REF: 1010005; Pump, t:slim X2, Basal-IQ, Medicare, REF: 1010006; Pump, t:slim X2, Basal-IQ, Medicare, REF: 1010007; Pump, t:slim X2, Control-IQ, REF: 1010009; Pump, t:slim X2, Control-IQ Replacement, REF: 1010010; Pump, t:slim X2, Control-IQ, Medicare, REF: 1010011; Pump, t:slim X2, Control-IQ, Refurbished Replacement, REF: 1010012; Pump, t:slim X2, Control-IQ, REF: 1012867; Pump, t:slim X2, Control-IQ, Medicare, REF: 1012868; Pump, t:slim X2, Control-IQ, Replacement, REF: 1012869; Pump, t:slim X2, Control-IQ 7.8, REF: 1013195; Pump, t:slim X2, Control-IQ 7.8, Medicare, REF: 1013196; Pump, t :slim X2, Control-IQ 7.8, Replacement, REF: 1013197; Pump, t:slim X2, Control-IQ 7.8, Refurbished Replacement, REF: 1013198
FDA Enforcement
Class I
·Ongoing·Tandem Diabetes Care, Inc.·September 3, 2025