16 results · 21ms · Sources: EU EUDAMED, US FDA

Get notified when this changes

We'll email you when new records match this search — new devices, new clearances, certificate changes, or withdrawals.

LIQUID ASSAYED CHEMISTRY CONTROL PREMIUM PLUS LEVEL 1,2 AND LEVEL 3.

FDA 510(k)
FDA Class 1 ·Clinical Chemistry

Gyrus ACMI

FDA UDI
Gyrus ACMI, LLC·00821925017696·APPLEBAUM INCUS REPLACEMENT 2.25 MM DENSE HYDRO...

LINEAR ST

FDA Adverse Event
Injury ·BOSTON SCIENTIFIC NEUROMODULATION·Product code LGW·May 7, 2024

GENCHEM ISE ELECTROLYTE REFERENCE

FDA 510(k)
FDA Class 2 ·Clinical Chemistry

ATEK SURGICAL GOWNS

FDA 510(k)
FDA Class 2 ·General, Plastic Surgery

FREESTYLE PRECISION NEO

FDA Adverse Event
Malfunction ·ABBOTT DIABETES CARE INC·Product code NBW·January 10, 2017

INTERSTIM

FDA Adverse Event
Injury ·MDT SOFAMOR DANEK PUERTO RICO MFG·Product code EZW·June 3, 2013

SYNCHROMED II

FDA Adverse Event
Injury ·MDT PUERTO RICO OPERATIONS CO., JUNCOS·Product code LKK·June 21, 2011

GE OEC 9800

FDA Adverse Event
Malfunction ·GE OEC MEDICAL SYSTEMS INC.·Product code JAA·September 3, 2008

UniCel DxH 600 Coulter Cellular Analysis System, REF number B23858. Product Usage: Note: The DxH 600 hematology analyzer is the same instrument as the DxH 800 (K140911), except that it is a benchtop unit with no instrument cart, computer stand, and no connectivity capabilities. DxH 800 intended use states: The UniCel DxH 800 Analyzer is a quantitative multi-parameter, automated hematology analyzer for in vitro diagnostic use in screening patient populations found in clinical laboratories. The UniCel¿ DxH 800 Analyzer identifies and enumerates the parameters indicated below on the following sample types: Whole Blood (Venous and Capillary) o WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, RDW-SD, PLT, MPV, NE%, NE#, LY%, LY#, MO%, MO#, EO%, EO#, BA%, BA#, NRBC%, NRBC#, RET%, RET#, MRV, IRF Pre-Diluted Whole Blood (Venous and Capillary) o WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, RDW-SD, PLT, MPV Body Fluids (cerebrospinal, serous and synovial) o TNC and RBC

FDA Enforcement
Class I ·Terminated·Beckman Coulter Inc.·May 29, 2019

UniCel DxH 900 Coulter Cellular Analysis System, REF number C11478 Product Usage: Note: The DxH 900 hematology analyzer is CLIA categorized under document CR180294 and is currently marketed as a member of the instrument family of the DxH 800 cleared under K140911, per FDA s guidance, Guidance for Industry and FDA Staff, Replacement Reagent and Instrument Family Policy . DxH 800 intended use states: The UniCel DxH 800 Analyzer is a quantitative multi-parameter, automated hematology analyzer for in vitro diagnostic use in screening patient populations found in clinical laboratories. The UniCel¿ DxH 800 Analyzer identifies and enumerates the parameters indicated below on the following sample types: Whole Blood (Venous and Capillary) o WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, RDW-SD, PLT, MPV, NE%, NE#, LY%, LY#, MO%, MO#, EO%, EO#, BA%, BA#, NRBC%, NRBC#, RET%, RET#, MRV, IRF Pre-Diluted Whole Blood (Venous and Capillary) o WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, RDW-SD, PLT, MPV Body Fluids (cerebrospinal, serous and synovial) o TNC and RBC

FDA Enforcement
Class I ·Terminated·Beckman Coulter Inc.·May 29, 2019

Microtek Medical, Inc. ORS Fluid Warming and Slush Drapes, Model #'s ORS-100, ORS-110, ORS-130, ORS-300, ORS-301, ORS-320, ORS-321, ORS-325, ORS-330, ORS-331 and ORS-2200. The ORS Fluid Warming and Slush Drapes are individually wrapped and placed in poly-Tyvek pouches with a label insert, then packaged as 24 per case in a labeled corrugated shipper box. Intended for use during various surgeries where warm irrigation, slush and/or cold solution are required.

FDA Enforcement
Class II ·Terminated·Ecolab Inc·September 30, 2015

UniCel DxH 600 Coulter Cellular Analysis System, REF number B23858. Product Usage: Note: The DxH 600 hematology analyzer is the same instrument as the DxH 800 (K140911), except that it is a benchtop unit with no instrument cart, computer stand, and no connectivity capabilities. DxH 800 intended use states: The UniCel DxH 800 Analyzer is a quantitative multi-parameter, automated hematology analyzer for in vitro diagnostic use in screening patient populations found in clinical laboratories. The UniCel DxH 800 Analyzer identifies and enumerates the parameters indicated below on the following sample types: Whole Blood (Venous and Capillary) o WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, RDW-SD, PLT, MPV, NE%, NE#, LY%, LY#, MO%, MO#, EO%, EO#, BA%, BA#, NRBC%, NRBC#, RET%, RET#, MRV, IRF Pre-Diluted Whole Blood (Venous and Capillary) o WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, RDW-SD, PLT, MPV Body Fluids (cerebrospinal, serous and synovial) o TNC and RBC

FDA Recall
Terminated ·Beckman Coulter Inc.·Product code GKZ·July 30, 2018

UniCel DxH 900 Coulter Cellular Analysis System, REF number C11478 Product Usage: Note: The DxH 900 hematology analyzer is CLIA categorized under document CR180294 and is currently marketed as a member of the instrument family of the DxH 800 cleared under K140911, per FDA s guidance, Guidance for Industry and FDA Staff, Replacement Reagent and Instrument Family Policy . DxH 800 intended use states: The UniCel DxH 800 Analyzer is a quantitative multi-parameter, automated hematology analyzer for in vitro diagnostic use in screening patient populations found in clinical laboratories. The UniCel DxH 800 Analyzer identifies and enumerates the parameters indicated below on the following sample types: Whole Blood (Venous and Capillary) o WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, RDW-SD, PLT, MPV, NE%, NE#, LY%, LY#, MO%, MO#, EO%, EO#, BA%, BA#, NRBC%, NRBC#, RET%, RET#, MRV, IRF Pre-Diluted Whole Blood (Venous and Capillary) o WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, RDW-SD, PLT, MPV Body Fluids (cerebrospinal, serous and synovial) o TNC and RBC

FDA Recall
Terminated ·Beckman Coulter Inc.·Product code GKZ·July 30, 2018

C-Series High Energy Linear Accelerator - Models: Novalis Tx, Trilogy, Trilogy Tx, Clinac iX, Clinac 2100 C/D, Clinac 2300C/D, Clinac 21EX, Clinac 23EX with versions 7, 8, 9 and 6 MV configuration and maximum dose rate of at least 6000 MU/min only. Varian High Energy Linear Accelerator is intended to provide sterotactic radiosurgery and precision radio-therapy for lesions, tumors and conditions anywhere in the body when radiation treatment is indicated.

FDA Enforcement
Class II ·Terminated·Varian Medical Systems, Inc.·September 24, 2014

C-Series: Clinac, Trilogy, Trilogy Tx. , Novalis high energy linear accelerators and UNIQUE single energy linear accelerator; Versions 7, 8 and 9. The UNIQUE is not sold in the US. Product Usage: The Varian High Energy Linear Accelerator is indicated for stereotactic radiosurgery and precision radiotherapy for lesions, tumors and conditions anywhere in the body when radiation treatment is indicated. The UNIQUE is a single energy medical linear accelerator. UNIQUE is indicated for precision radiotherapy for lesions, tumors and conditions anywhere in the body where radiation treatment is indicated.

FDA Enforcement
Class II ·Terminated·Varian Medical Systems, Inc.·December 11, 2013