14 results
·
21ms
·
Sources: EU EUDAMED, US FDA
Filters
Regulation: Us FDA
×
CYBERWAND STERILE PROBE SET
FDA 510(k)
FDA Class 2
·Gastroenterology, Urology
GE 0.7T SIGNA OPENSPEED WITH EXCITE MR SYSTEM
FDA 510(k)
FDA Class 2
·Radiology
SIGNATURE PLANNER; SIGNATURE GUIDES
FDA 510(k)
FDA Class 2
·Orthopedic
DEXCOM G6 CONTINUOUS GLUCOSE MONITORING SYSTEM
FDA Adverse Event
Malfunction
·DEXCOM, INC.·Product code QBJ·June 4, 2024
WAVEWRITER ALPHA PRIME
FDA Adverse Event
Injury
·BOSTON SCIENTIFIC NEUROMODULATION·Product code LGW·October 24, 2023
PELVISOFT ACELLULAR COLLAGEN BIOMESH
FDA Adverse Event
Injury
·TISSUE SCIENCE LABORATORIES·Product code FTM·May 16, 2013
EON
FDA Adverse Event
Injury
·ST JUDE MEDICAL, NEUROMODULATION·Product code GZB·September 29, 2014
HOMECHOICE AUTOMATED PD SET WITH CASSETTE
FDA Adverse Event
Injury
·BAXTER HEALTHCARE - MOUNTAIN HOME·Product code FKX·June 17, 2011
7MM TI MULTILOC HUMERAL NAIL RIGHT/CANN/225MM-STERILE
FDA Adverse Event
Injury
·OBERDORF SYNTHES PRODUKTIONS GMBH·Product code HSB·August 12, 2020
MPACT ACETABULAR SHELL Ø 52 TWO-HOLES
FDA Adverse Event
Injury
·MEDACTA INTERNATIONAL SA·Product code LPH·July 15, 2016
SOL SYS 8IN CALCAR SZ12 Packaging: Product is packed within a poly protector, with protection added as needed for fragile points. The entire stem is then placed within a foam sleeve for added protection. The assembly is then placed and sealed in an inner and outer tray for aseptic transfer. The sealed package is placed into a folding carton, labeled, and shrink wrapped. Intended Use: SOLUTION System Calcar Stems are used in total hip arthroplasty (THA) to provide increased patient mobility and reduce pain by replacing the damaged hip joint articulation in patients where there is evidence of sufficient sound bone to seat and support the components.
FDA Enforcement
Class II
·Terminated·DePuy Orthopaedics, Inc.·December 26, 2012
7) Signa OpenSpeed (K032795 GE 0.7T Signa OpenSpeed with EXCITE MR System) The 0.7T Signa Openspeed with Excite Magnetic Resonance System is an open, whole body scanner designed to support improved higher resolution imaging and shorter scan times. The Signa 0.7T Signa Openspeed with Excite Magnetic Resonance System is indicated for use as a diagnostic imaging device to produce transverse, sagittal, coronal and oblique images of the internal structures and organs of the entire body, including, but not limited to, the musculocskeletal, vascular, cardiac, and neuro systems. The images produced by the Signa 0.7T Signa Openspeed with Excite Magnetic Resonance System reflect the spatial distribution of protons (hydrogen nuclei) exhibiting magnetic resonance. The NMR properties that determine the image appearance are proton density, spinlattice relaxation time (T1), spin-spin relaxation time (T2) and flow. When interpreted by a trained physician, these images provide information that can be useful in determining a diagnosis. Due to the open design of the system, the Signa 0.7T Signa OpenSpeed with Excite may also be used for imaging during interventional procedures when performed with MR compatible devices such as, in-room display and MR safe biopsy needles. . .
FDA Recall
Terminated
·GE Healthcare, LLC·Product code LNH·November 9, 2010
Achieva 1.5T
FDA Enforcement
Class II
·Ongoing·Philips North America Llc·November 29, 2023
Alaris Syringe Pump, Model No. 8110. Delivers fluids. Expansion of Affected Units: BOM Housing Assembly Service, Part No. 49000226, and Lower Housing/Carriage Block Assembly, Part No. 148188-100.
FDA Enforcement
Class I
·Terminated·CareFusion 303, Inc.·August 26, 2015