DIMENSION VISTA ETHYL ALCOHOL (ALC), ALKALINE PHOSPHATASE (ALP), CALCIUM (CA0 FLEX, LACTIC ACID (LA) FLEX REAGENT CARTRI

FDA 510(k)
FDA Class 2 ·Clinical Toxicology

Puritan Bennett

FDA UDI
Covidien LP·10884521078369·700 Series Ventilator,Model 740

BILAYER MATRIX WOUND DRESSING

FDA 510(k)
FDA Unclassified ·Unknown

NON-CHLORINATED, POLYMER COATED POWDER-FREE NITRILE PATIENT EXAMINATION GLOVES

FDA 510(k)
FDA Class 1 ·General Hospital

CERENOVUS ENTERPRISE

FDA Adverse Event
Malfunction ·MEDOS INTERNATIONAL SARL·Product code NJE·November 10, 2025

ACCU-CHEK ® SPIRIT COMBO

FDA Adverse Event
Injury ·ROCHE DIABETES CARE AG·Product code LZG·April 16, 2013

SYNCHROMED II

FDA Adverse Event
Malfunction ·MEDTRONIC NEUROMODULATION·Product code LKK·March 30, 2011

MONOPOLAR CURVED SCISSORS INSTRUMENT

FDA Adverse Event
Malfunction ·INTUITIVE SURGICAL, INC.·Product code GEI·June 13, 2008

The MTS Set is a single-use, sterile (EO), non-pyrogenic, optional accessory that provides additional connections/disconnections when used with a stay"safe compatible cycler set during acute and chronic PD treatment. The MTS Set utilizes the same PIN engagement technology used in Fresenius stay"safe Patient Connectors (K041792). The MTS Set consists of two (2) stay"safe PIN Connectors at the proximal end, tubing, and a Safe-Lock connector at the distal end. The MTS Set is attached to a cycler set by a patient, care partner, or healthcare professional. The MTS Set is attached during setup to make additional connections to the cycler set when they are prescribed by a physician or when an interruption in treatment is necessary.

FDA Enforcement
Class II ·Terminated·Fresenius Medical Care Holdings, Inc.·July 28, 2021

The MTS Set is a single-use, sterile (EO), non-pyrogenic, optional accessory that provides additional connections/disconnections when used with a stay"safe compatible cycler set during acute and chronic PD treatment. The MTS Set utilizes the same PIN engagement technology used in Fresenius stay"safe Patient Connectors (K041792). The MTS Set consists of two (2) stay"safe PIN Connectors at the proximal end, tubing, and a Safe-Lock connector at the distal end. The MTS Set is attached to a cycler set by a patient, care partner, or healthcare professional. The MTS Set is attached during setup to make additional connections to the cycler set when they are prescribed by a physician or when an interruption in treatment is necessary.

FDA Recall
Terminated ·Fresenius Medical Care Holdings, Inc.·Product code KDJ·April 28, 2021

Stryker MA204 Bed Model (FL25E) Beds are intended for medical purposes in both general patient care as well as critical care environments. Each uses built-in electric motors and controls which can be operated by the patient, or caregiver, to adjust the height and/or surface contour of the bed.The devices listed above also include movable and latchable side rails which can be lowered or raised to help prevent patient fall and subsequent injury. The Beds include an optional Scale (Models: FL20E, FL25E, FL28C, FL28EX) as well as an optional Bed Exit (1 Zone) or Chaperone

FDA Enforcement
Class II ·Terminated·Stryker Medical Division of Stryker Corporation·July 4, 2012

CADD¿- Solis Ambulatory Infusion Pump, Model 2111 & 2112, Version 1.0, Version 2.0 and Version 3.0 & Model 2120, Version 1.0. Provide measured drug therapy to patients in hospital or outpatient settings.

FDA Enforcement
Class II ·Terminated·Smiths Medical ASD, Inc.·June 24, 2015