15 results
·
22ms
·
Sources: EU EUDAMED, US FDA
Filters
Regulation: Us FDA
×
AQUASOFT ALL-DAY & ALL-DAY T (HIOXIFILCON A) DAILY WEAR CONTACT LENS
FDA 510(k)
FDA Class 2
·Ophthalmic
PYRAMESH® C Titanium Mesh
FDA UDI
MEDTRONIC SOFAMOR DANEK, INC.·00763000855833·MESH 9052290 PYRAMESH IMP 22MMX90MM RND
PYRAMESH® C Titanium Mesh
FDA UDI
MEDTRONIC SOFAMOR DANEK, INC.·00681490484695·MESH 9052290 PYRAMESH IMP 22MMX90MM RND
RAPIDIA
FDA 510(k)
FDA Class 2
·Radiology
ABL-700 SERIES, MODEL ABL 7XX (VARIOUS MODELS)
FDA 510(k)
FDA Class 2
·Clinical Chemistry
NEURON DELIVERY CATHETER 053
FDA Adverse Event
Malfunction
·PENUMBRA, INC.·Product code DQY·March 16, 2010
NUVASIVE
FDA Adverse Event
Injury
·NUVASIVE·Product code NKB·January 10, 2011
5) Signa HDx (K052293 Signa HDx and HDxt MR Systems) Signa HDx or Signa HDxt (K052293 Signa HDx and HDxt MR Systems) Signa HDxt (K052293 Signa HDx and HDxt MR Systems ) The GE Signa HDe MR system is a whole body magnetic resonance scanner designed to support high resolution, high signal-to-noise ratio, and short scan times. The Signa HDe MR system is indicated for use as a diagnostic imaging device to produce axial sagittal, coronal and oblique images, spectra, dynamic images of the internal structures and organs of the entire body, including, but not limited to, head, neck, TMJ, spine, breast, heart, abdomen, pelvis, joints, prostate, blood vessels, and musculoskeletal regions of the body. The images produced by the Signa HDe system reflect the spatial distribution of protons (hydrogen nuclei) exhibiting magnetic resonance. These images and/or spectra when interpreted by a trained physician yield information that may assist in diagnosis.
FDA Recall
Terminated
·GE Healthcare, LLC·Product code LNH·November 9, 2010
EON MINI
FDA Adverse Event
Injury
·ST. JUDE MEDICAL - NEUROMODULATION·Product code LGW·April 4, 2013
VITALITY 2
FDA Adverse Event
Death
·GUIDANT CRM CLONMEL IRELAND·Product code LWS·April 12, 2011
ACCU-CHEK COMFORT CURVE TEST STRIPS
FDA Adverse Event
Malfunction
·ROCHE DIAGNOSTICS·Product code LFR·May 23, 2008
Stryker MA204 Bed Model (FL25E) Beds are intended for medical purposes in both general patient care as well as critical care environments. Each uses built-in electric motors and controls which can be operated by the patient, or caregiver, to adjust the height and/or surface contour of the bed.The devices listed above also include movable and latchable side rails which can be lowered or raised to help prevent patient fall and subsequent injury. The Beds include an optional Scale (Models: FL20E, FL25E, FL28C, FL28EX) as well as an optional Bed Exit (1 Zone) or Chaperone
FDA Enforcement
Class II
·Terminated·Stryker Medical Division of Stryker Corporation·July 4, 2012
CADD-Solis VIP ambulatory Infusion Pumps, Model 2120 (21-2120, 21-2125, and 21-2127) Indicated for the following uses: Intra-arterial, subcutaneous, intraperitoneal, in close proximity to nerves, into an intraoperative site, epidural space or subarachnoid space. Therapies that require a continuous rate of infusion, intermittent bolus, and/or with patient-controlled demand doses.
FDA Enforcement
Class I
·Ongoing·Smiths Medical ASD Inc.·August 14, 2024
Boston Scientific COGNIS CRT-D, Cardiac Resynchronization Therapy Defibrillator, models N118, N119. The following models are not available in the US: models N106, N107, P106, P107. Sterilized using ethylene oxide. Product Usage: Boston Scientific cardiac resynchronization therapy defibrillators (CRT-Ds) are indicated for patients with moderate to severe heart failure who remain symptomatic despite stable, optimal heart failure drug therapy and have left ventricular dysfunction and QRS duration > or equal to 120 ms. This family of pulse generators provide a variety of therapies including: -Ventricular tachyarrhythmia therapy, which is used to treat rhythms associated with sudden cardiac death such as VT and VF; -Cardiac Resynchronization Therapy (CRT), which treats heart failure by resynchronizing ventricular contractions through biventricular electrical stimulation; -Bradycardia pacing, including adaptive rate pacing, to detect and treat bradyarrhythmias and to provide cardiac rate support after defibrillation therapy.
FDA Enforcement
Class II
·Terminated·Boston Scientific CRM Corp·October 29, 2014
Brand Name: ¿ cobas c 6000 MODULAR Series System e 601 ¿ cobas c 8000 MODULAR Series System - e 602 ¿ Roche / Hitachi MODULAR Analytics Combination System Model/Catalog/Part Number: MODULAR Analytics E 170 ¿ 03022109001 ¿ 03023109973 ¿ 03739040001 ¿ 03739040692 ¿ 05023572001 ¿ 05023599001 cobas e 601 module ¿ 04745922001 ¿ 04745922692 ¿ 05036348001 ¿ 05036348692 ¿ 05860652001 cobas e 602 module ¿ 05990378001 The Roche/Hitachi MODULAR Analytics System (E170) is a fully automated, random-access, software- controlled system for immunoassay and photometric analysis intended for qualitative and quantitative in vitro determinations using a wide variety of tests. The cobas 6000 series (e 601) is a fully automated, random-access, software-controlled system for immunoassay and photometric analysis intended for qualitative and quantitative in vitro determinations using a wide variety of tests. It is optimized for high throughput workloads in the professional environment using a combination of Ion selective electrodes (ISE), a photometric analysis unit an immunoassay analysis module. The cobas 8000 Modular Analyze Series (e602) is a fully automated system for Clinical chemistry analysis, intended for the in vitro qualitative and quantitative determination of analytes in body fluids. It is optimized for high throughput workloads in the professional environment using a combination of ion selective electrodes (ISE) and a photometric analysis unit.
FDA Enforcement
Class II
·Terminated·Roche Diagnostics Corporation·January 24, 2018