12 results · 20ms · Sources: EU EUDAMED, US FDA

Get notified when this changes

We'll email you when new records match this search — new devices, new clearances, certificate changes, or withdrawals.

SYNTHES (USA) NEW/STERIAL ORBITAL PLATES

FDA 510(k)
FDA Class 2 ·Dental

STATLYTE NA/K/CL/LI ANALYZER

FDA 510(k)
FDA Class 2 ·Clinical Chemistry

MAC TWO-LUMEN CENTRAL VENOUS KIT WITH ARROWG ARD BLUE ANTIMICROBIAL SURFACE AND INTEGRAL HEMOSTASIS VALVE/SIDE PORT

FDA 510(k)
FDA Class 2 ·Cardiovascular

ELLIPSE VR

FDA Adverse Event
Injury ·ST. JUDE MEDICAL, INC., CRMD·Product code LWS·August 22, 2014

TRANSTAR STRETCHER

FDA Adverse Event
Malfunction ·HILL-ROM INC.·Product code FPO·March 21, 2011

MIST THERAPY SYSTEM

FDA Adverse Event
Other ·CELLERATION, INC.·Product code NRB·April 15, 2008

ZIMMER NEXEL TOTAL ELBOW HUMERAL COMPONENT PLASMA SPRAYED

FDA Adverse Event
Injury ·ZIMMER BIOMET, INC.·Product code JDC·November 14, 2023

ZIMMER NEXEL TOTAL ELBOW VIVACIT E HIGHLY CROSSLINKED POLY ARTICULATION KIT

FDA Adverse Event
Injury ·ZIMMER BIOMET, INC.·Product code JDC·November 14, 2023

ARROWg+ard Blue MAC Two-Lumen Central Venous Access Kit The MAC(TM) Multi-Lumen Central Venous Access Device with ARROWg+ard Blue(R) permits venous access and catheter introduction to the central circulation. It may be inserted into the jugular, subclavian, or femoral veins. The ARROWg+ard(R) technology is intended to help provide protection against catheter-related infections. Clinical data have not been collected that demonstrate the use of the ARROWg+ard(R) antimicrobial surface in decreasing catheter-related infections for this device. It is not intended to be used as a treatment for existing infections, nor is it indicated for long-term use.

FDA Enforcement
Class II ·Terminated·Arrow International Inc·June 14, 2017

Advantage Workstation Volume Share 2 (versionAW4.4_04) with Volume Viewer 3 and 3.1 (version7.0 to version7.5 and version 8.1) and only when or more of these applications is installed: " VesselIQ Xpress or AVA Xpress " CardIQ Xpress Pro or Plus " CardEP " CardIQ Fusion PET or SPECT Advantage Workstations Volume Share (v.AW4.3) and AW4.2 (version4.2-05 and above) provided with Volume Viewer 2(version6.0 to version6.11) and only when one or both of these applications is installed: " CardIQ Xpress Pro or Plus " CardEP Advantage Workstations AW Volume Share 2 (AW version 4.4). ONLY IF ONE OF FOLLOWING APPLICATIONS IS INSTALLED: VesselIQ Xpress or AVA Xpress CardIQ Xpress Pro or Plus CardEP CardIQ Fusion PET or SPECT provided with Volume Viewer 3 and 3.1 from versions 7.0 to 7.5 and 8.1. To verify the version installed on your system: Select the Admin menu from the Patient list page. Then select Display Configuration. You will find the version of your system in Installed Application(s). This version will appear as vxtl_7.x or vxtl_8.x. Intended use: K993792: Smart Vessel Analysis (Smart VA) is a software post-processing option for the Advantage Workstation (AW) platform, which can be used in the analysis of 3D angiography data. It provides a number of display, measurement and batch filming/archive features and will aid physicians in studying user-selected vessels for stenosis analysis, pre/post stent planning and directional vessel tortuosity visualization. K031261: Card EP is a post processing software option for the Advantage Workstation (AW) Platform. This product can be used for the analysis of CT angiographic images for the assessment of the heart to include the atria, pulmonary veins, and coronary sinus. It provides quantitative analysis tools which include a number of display, measurement and model export capabilities. This product can be used to aid trained physicians in the visualization and assessment of cardiac anatomy. K041267: CardIQ Analysis III is a CT image analysis software package, which allows the visualization of 2D and 3D medical image data of the heart derived from DICOM 3.0 compliant CT scans for the purpose of cardiovascular disease assessment. It provides functionally for 2D/3D rendering, assessment of calcified and non-calcified plaque to determine the densities of the plaque within a coronary artery, ventricular function of the heart, and measurement tools to detect coronary artery stenosis. This product can be used to aid a trained physician to process, render, review, archive, print and visualizing cardiac anatomy and coronary vessels. CardIQ Analysis II will run on the AW workstation, scanner operator console and PACS system. K061370: CardIQ Fusion is intended to provide an optimized non-invasive application to analyze vascular anatomy and pathology, aid in the assessment of functional data e.g. PET perfusion, and aid in tailoring treatment plans based on the fused anatomical and functional information. Anatomical data could be from a set of Computed Tomography (CT) Angiographic images while functional data could be from PET, SPECT, or processed CT data. CardIQ Fusion is a software post-processing package for the Advantage Workstation (AW) platform, PET/CT and CT scanners and PACS reading stations. It is an additional tool for the analysis of 3D CT angiographic cardiac images/data providing a number of display, measurements and batch filming/archive features to study user-selected vessels. Also included is the capability to visualize reformatted CT/PET/SPECT perfusion and viability data. Finally, it provides different ways of visualizing CT anatomy fused with PET/SPECT functional information. With CardIQ Fusion, clinicians have the opportunity to overlay functional information over the (CT) anatomy of a patient's heart, and thus, they can potentially tailor their decision for that particular patient. CardIQ Fusion provides the visualization of the vessels in severa

FDA Recall
Terminated ·GE Healthcare, LLC·Product code LLZ·May 29, 2012

Advantage Workstation Volume Share 2 (versionAW4.4_04) with Volume Viewer 3 and 3.1 (version7.0 to version7.5 and version 8.1) and only when or more of these applications is installed: " VesselIQ Xpress or AVA Xpress " CardIQ Xpress Pro or Plus " CardEP " CardIQ Fusion PET or SPECT Advantage Workstations Volume Share (v.AW4.3) and AW4.2 (version4.2-05 and above) provided with Volume Viewer 2(version6.0 to version6.11) and only when one or both of these applications is installed: " CardIQ Xpress Pro or Plus " CardEP Advantage Workstations AW Volume Share 2 (AW version 4.4). ONLY IF ONE OF FOLLOWING APPLICATIONS IS INSTALLED: ¿ VesselIQ Xpress or AVA Xpress ¿ CardIQ Xpress Pro or Plus ¿ CardEP ¿ CardIQ Fusion PET or SPECT provided with Volume Viewer 3 and 3.1 from versions 7.0 to 7.5 and 8.1. To verify the version installed on your system: Select the Admin menu from the Patient list page. Then select Display Configuration. You will find the version of your system in Installed Application(s). This version will appear as vxtl_7.x or vxtl_8.x. Intended use: K993792: Smart Vessel Analysis (Smart VA) is a software post-processing option for the Advantage Workstation (AW) platform, which can be used in the analysis of 3D angiography data. It provides a number of display, measurement and batch filming/archive features and will aid physicians in studying user-selected vessels for stenosis analysis, pre/post stent planning and directional vessel tortuosity visualization. K031261: Card EP is a post processing software option for the Advantage Workstation (AW) Platform. This product can be used for the analysis of CT angiographic images for the assessment of the heart to include the atria, pulmonary veins, and coronary sinus. It provides quantitative analysis tools which include a number of display, measurement and model export capabilities. This product can be used to aid trained physicians in the visualization and assessment of cardiac anatomy. K041267: CardIQ Analysis III is a CT image analysis software package, which allows the visualization of 2D and 3D medical image data of the heart derived from DICOM 3.0 compliant CT scans for the purpose of cardiovascular disease assessment. It provides functionally for 2D/3D rendering, assessment of calcified and non-calcified plaque to determine the densities of the plaque within a coronary artery, ventricular function of the heart, and measurement tools to detect coronary artery stenosis. This product can be used to aid a trained physician to process, render, review, archive, print and visualizing cardiac anatomy and coronary vessels. CardIQ Analysis II will run on the AW workstation, scanner operator console and PACS system. K061370: CardIQ Fusion is intended to provide an optimized non-invasive application to analyze vascular anatomy and pathology, aid in the assessment of functional data e.g. PET perfusion, and aid in tailoring treatment plans based on the fused anatomical and functional information. Anatomical data could be from a set of Computed Tomography (CT) Angiographic images while functional data could be from PET, SPECT, or processed CT data. CardIQ Fusion is a software post-processing package for the Advantage Workstation (AW) platform, PET/CT and CT scanners and PACS reading stations. It is an additional tool for the analysis of 3D CT angiographic cardiac images/data providing a number of display, measurements and batch filming/archive features to study user-selected vessels. Also included is the capability to visualize reformatted CT/PET/SPECT perfusion and viability data. Finally, it provides different ways of visualizing CT anatomy fused with PET/SPECT functional information. With CardIQ Fusion, clinicians have the opportunity to overlay functional information over the (CT) anatomy of a patient's heart, and thus, they can potentially tailor their decision for that particular patient. CardIQ Fusion provides the visualization of the vessels in severa

FDA Enforcement
Class II ·Terminated·GE Healthcare, LLC·December 26, 2012

Reamer / Irrigator / Aspirator (RIA): RIA Drive Shafts, RIA Tube Assemblies, sterile, RIA Reamer Head, sterile (12.0mm-19.0mm); intended to clear the medullary canal of bone marrow and debris and to effectively size the medullary canal for the acceptance of an intramedullary implant or prosthesis

FDA Enforcement
Class II ·Terminated·Synthes, Inc.·July 22, 2015