11 results · 23ms · Sources: EU EUDAMED, US FDA

Get notified when this changes

We'll email you when new records match this search — new devices, new clearances, certificate changes, or withdrawals.

SKINTACT ECG ELECTRODES WITH KL 02 LIQUID GEL

FDA 510(k)
FDA Class 2 ·Cardiovascular

TRIAGE DRUGS OF ABUSE PANEL PLUS PPX, MODEL CATALOG 92002

FDA 510(k)
FDA Class 2 ·Clinical Toxicology

COLORADO 2 SPINAL SYSTEM

FDA 510(k)
FDA Class 2 ·Orthopedic

BD VACUTAINER® BORIC ACID SODIUM BORATE/FORMATE C&S URINE TUBE

FDA Adverse Event
Malfunction ·BECTON, DICKINSON & CO.·Product code JSM·April 25, 2018

ANIMAS INSULIN INFUSION PUMP

FDA Adverse Event
Injury ·ANIMAS CORPORATION·Product code LZG·March 27, 2013

DA VINCI SI SURGICAL SYSTEM

FDA Adverse Event
Other ·INTUITIVE SURGICAL,INC.·Product code NAY·March 18, 2011

FG 6301 DUAL CHNL VOL INF PUMP2M8064 SERVICE

FDA Adverse Event
Malfunction ·BAXTER HEALTHCARE PTE LTD·Product code FRN·March 27, 2008

Product Brand Names: Triage Drugs of Abuse Panel 8 Test Kit (K924476), Triage Drugs of Abuse Panel Plus TCA (K973784), & Triage Drugs of Abuse Panel Plus PPX (K014247) Model Number: 90008, 92002, & 92000 Type of Packaging (i.e. box, plastic bag): For all affected device types: 25 individually pouched devices in a labeled kit box. The Triage Drugs of Abuse Panel plus Tricyclic Antidepressants utilizes a patented immunochemistry, ASCENDTM MULTIMMUNOASSAY (AMIATM). Each AMIATM assay is a competitive binding immunoassay in which a chemically labeled drug (drug conjugate) competes with drug which may be present in the urine for antibody binding sites. After a brief incubation, the reaction mixture is transferred to the membrane in the Detection Area. Free drug conjugate that is displaced from antibody binding sites by drug in the urine, binds to a zone of monoclonal antibody that is immobilized on the membrane. The membrane is washed to remove the unbound conjugate and clear the background. Test results are visually read. The Triage Drugs of Abuse Panel plus Tricyclic Antidepressants is an immunoassay used for the qualitative determination of the presence of the major metabolites of drugs of abuse, (Phencyclidine, Benzodiazepines, Cocaine Metabolite, Amphetamines, THC, Opiates, Barbiturates), and Tricyclic Antidepressants in urine.

FDA Recall
Terminated ·Alere San Diego·Product code DIS·January 4, 2012

The Propaq LT Series monitors. Model numbers 802LTAN, 802LT0N, and 802LTRN. These devices are indicated for ECG, noninvasive blood pressure (NIBP), respiration and SpO2. The most likely locations for patients to be monitored by these devices are hospital general medical-surgical, telemetry, and intermediate care floors, hospital emergency departments, transport, emergency medical services, and other healthcare applications. intended to be used by clinicians and medically qualified personnel for single or multiparameter vital signs monitoring of ambulatory and nonambulatory patients, including neonate, pediatric and adult patients. These devices are indicated for ECG, noninvasive blood pressure (NIBP), respiration and SpO2. The most likely locations for patients to be monitored by these devices are hospital general medicalsurgical, telemetry, and intermediate care floors, hospital emergency departments, transport, emergency medical services, and other healthcare applications. The monitors can be used as stand-alone devices or as devices networked to an Acuity Central Station through wireless communication over a Welch Allyn FlexNet network.

FDA Enforcement
Class II ·Terminated·Welch Allyn Protocol, Inc·January 15, 2014

Fortify Assura, Sterile EO, Model #/ Part #: CD1257-40/100042322, 100059623; CD1257-40Q/100042341, 100059535; CD1259-40/100041914, 100042338, 100059536, 100059646, 100081567; CD1259-40Q/100041931, 100042339, 100059537, 100059620, 100059626, 100078685; CD1263-40/100042948; CD1263-40Q/100042949; CD1357-40C/100080365, 100080377, 100083441; CD1357-40Q/100080389, 100080390, 100083388; CD1359-40/100078740, 100083267, 100096839; CD1359-40C/100078500, 100078969, 100079372, 100079373, 100083442, 100083443, 100117545; CD1359-40Q/100078804, 100079155, 100079413, 100083445, 100096884; CD1359-40QC/100078603, 100079145, 100079146, 100079239, 100083405, 100083444, 100117632, 100127000, 100127065; CD1363-40C/100080349; CD1363-40Q/100080317; CD1391-40C/100080756; CD1391-40QC/100080783; CD2257-40/100042337, 100059839; CD2257-40Q/100042342, 100059842; CD2259-40/100041893, 100042308, 100059794, 100059907, 100082567; CD2259-40Q/100041894, 100042309, 100059845, 100059873, 100078610; CD2263-40/100042950; CD2263-40Q/100043201; CD2357-40C/100080404, 100080413, 100083490; CD2357-40Q/100080319, 100080412, 100083492; CD2359-40/100078750, 100083466; CD2359-40C/100078651, 100079201, 100079240, 100079442, 100083501, 100083502, 100117546; CD2359-40Q/100078841, 100079109, 100083472; CD2359-40QC/100078652, 100079156, 100079157, 100079337, 100083407, 100083465, 100117580, 100127092, 100127103; CD2363-40C/100080416; CD2363-40Q/100080407; CD2391-40C/100080784; CD2391-40QC/100080744

FDA Enforcement
Class II ·Terminated·St Jude Medical Inc.·July 4, 2018

The Spirit Select Bed, Model 5700 Spirit Plus /with high rail siderail option

FDA Enforcement
Class II ·Terminated·Stryker Medical Division of Stryker Corporation·November 21, 2018