15 results · 21ms · Sources: EU EUDAMED, US FDA

Get notified when this changes

We'll email you when new records match this search — new devices, new clearances, certificate changes, or withdrawals.

REPROCESSED EXTERNAL FIXATION DEVICE

FDA 510(k)
FDA Class 2 ·Orthopedic

NA

FDA UDI
Stryker Leibinger GmbH & Co. KG·37613154184799·Bone Screws, emergency, MP, Cross-Pin

CODAN US I.V. ADMINISTRATION SET, MODEL B400 SP

FDA 510(k)
FDA Class 2 ·General Hospital

OSSTELL RESONANCE FREQUENCY ANALYZER

FDA 510(k)
FDA Class 1 ·Dental

ACCESS ESTRADIOL REAGENTS ON THE ACCESS IMMUNOASSAY ANALYZER

FDA Adverse Event
Malfunction ·BECKMAN COULTER INC.·Product code JIS·March 5, 2012

EASYPUMP: LT 270-54:270ML, 5ML/HR

FDA Adverse Event
Malfunction ·I-FLOW, LLC,·Product code MEB·October 24, 2014

ACCESS® VITAMIN B12

FDA Adverse Event
Malfunction ·BECKMAN COULTER, INC.·Product code CDD·February 1, 2012

SYNCHROMED EL

FDA Adverse Event
Injury ·RICE CREEK MFG·Product code LKK·March 27, 2013

ACRYSOF

FDA Adverse Event
Other ·ALCON RESEARCH, LTD. / HUNTINGTON·Product code HQL·February 18, 2011

DERMABOND TOPICAL SKIN ADHESIVE

FDA Adverse Event
Other ·CLOSURE MEDICAL CORP.·Product code MPN·April 1, 2008

ACCESS® VITAMIN B12

FDA Adverse Event
Malfunction ·BECKMAN COULTER, INC.·Product code CDD·February 1, 2012

The Propaq LT Series monitors. Model numbers 802LTAN, 802LT0N, and 802LTRN. These devices are indicated for ECG, noninvasive blood pressure (NIBP), respiration and SpO2. The most likely locations for patients to be monitored by these devices are hospital general medical-surgical, telemetry, and intermediate care floors, hospital emergency departments, transport, emergency medical services, and other healthcare applications. intended to be used by clinicians and medically qualified personnel for single or multiparameter vital signs monitoring of ambulatory and nonambulatory patients, including neonate, pediatric and adult patients. These devices are indicated for ECG, noninvasive blood pressure (NIBP), respiration and SpO2. The most likely locations for patients to be monitored by these devices are hospital general medicalsurgical, telemetry, and intermediate care floors, hospital emergency departments, transport, emergency medical services, and other healthcare applications. The monitors can be used as stand-alone devices or as devices networked to an Acuity Central Station through wireless communication over a Welch Allyn FlexNet network.

FDA Enforcement
Class II ·Terminated·Welch Allyn Protocol, Inc·January 15, 2014

OPTETRAK LOGIC Polyethylene Tibial Inserts, labeled as the following: a. OPTETRAK Logic PS Tibial Inserts, Product Line 02-012-35-XXXX; b. OPTETRAK Logic PSC Tibial Inserts, Product Line 02-012-44-XXXX; c. OPTETRAK Logic CR Tibial Inserts, Product Line 02-012-47-XXXX; d. OPTETRAK Logic CR Slope + Tibial Inserts, Product Line 02-012-48-XXXX; e. OPTETRAK Logic CR Slope ++ Tibial Inserts, Product Line 02-012-49-XXXX; f. OPTETRAK Logic CRC Tibial Inserts, Product Line 02-012-51-XXXX; g. OPTETRAK Logic CC Tibial Inserts, Product Line 02-012-65-XXXX; Affected 510(k) numbers include: K033883, K132161, K093360, K110547, K111400, K121307, K123342, K150890. NOTE: Information reflects Exactech recall expansion initiated on 02/07/2022.

FDA Enforcement
Class II ·Ongoing·Exactech, Inc.·October 13, 2021

CADD-Solis VIP ambulatory Infusion Pumps, Model 2110. Indicated for the following uses: Intra-arterial, subcutaneous, intraperitoneal, in close proximity to nerves, into an intraoperative site, epidural space or subarachnoid space. Therapies that require a continuous rate of infusion, intermittent bolus, and/or with patient-controlled demand doses.

FDA Enforcement
Class I ·Ongoing·Smiths Medical ASD Inc.·August 14, 2024

Ellipse, Sterile EO, Model #/ Part #: CD1275-36/100116115; CD1275-36Q/100116116; CD1277-36/100048388, 100048391, 100060126, 100116208, 10011636; CD1277-36Q/100048374, 100048394, 100060198, 100098497, 100116268, 100116345; CD1293-36Q/100057838; CD1309-36/100057717; CD1309-36Q/100057718; CD1311-36/100057802, 100060153; CD1311-36Q/100057803, 100060174, 100116264; CD1377-36/100078796, 100079180, 100096847; CD1377-36C/100078612, 100079197, 100079368, 100116120, 100116407, 100116447; CD1377-36Q/100078747, 100079210, 100096848, 100116385, 100116423, 100116427; CD1377-36QC/100078602, 100079199, 100079229, 100116398, 100116409, 100116466,100116485, 100127151, 100127152, 100127153; CD1393-36C/100116461; CD1393-36QC/100080656, 100116339; CD1409-36Q/100080251; CD1411-36C/100080197, 100080232, 100116411, 100116481; CD1411-36Q/100080244, 100080245, 100116338, 100116464; CD1411-36QC/100116337; CD2275-36/100116355; CD2275-36Q/100116349; CD2277-36/100048359, 100048402, 100116206, 100116207; CD2277-36Q/100048377, 100048404,100060190, 100098661, 100116342, 100116350; CD2293-36/100057765; CD2293-36Q/100057766; CD2309-36/100057804; CD2309-36Q/100057763; CD2311-36/100057679, 100060100; CD2311-36Q/100057835, 100060161, 100116351; CD2377-36/100078811, 100079226, 100096774; CD2377-36C/100078601,100079225, 100079304, 100116405, 100116424, 100116484; CD2377-36Q/100078812,100079208, 100096838, 100116406, 100116414, 100116437; CD2377-36QC/100078579, 100079176, 100079352, 100116413, 100116422, 100116436, 100116482, 100127100, 100127154, 100127181; CD2393-36C/100080653, 100116416; CD2393-36QC/100080655, 100116451; CD2409-36C/100079997; CD2409-36Q/100080149; CD2411-36C/100079986, 100080104, 100116118, 100116444; CD2411-36Q/100080180, 100080230, 100116370, 100116420

FDA Enforcement
Class II ·Terminated·St Jude Medical Inc.·July 4, 2018