90 results · 15ms · Sources: EU EUDAMED, US FDA

Get notified when this changes

We'll email you when new records match this search — new devices, new clearances, certificate changes, or withdrawals.

Battery Mobile X-ray Unit EASY MOVING Model with telescopic column 3.1, model numbers: a. SM-20HF-Batt; b. SM-32HF-Batt; c. SM-40HF-Batt; d. SM-50HF-Batt; e. SM-40-HF-B-D-VIR; f. SM-20HF-B-D-KM (AeroDR X30); g. SM-32-HF-B-D-KM (AeroDR X30); h. SM-40HF-B-D-KM (AeroDR X30); i. SM-50HF-B-D-KM (AeroDR X30); j. MobileDiagnost wDR.

FDA Enforcement
Class II ·Ongoing·SEDECAL SA·May 8, 2024

CDC, Influenza A/H5 Subtyping Kit, Model/Catalog Number: FluIVD03-11

FDA Enforcement
Class II ·Terminated·Centers For Disease Control and Prevention·July 3, 2024

ProBeam Proton Therapy System (HGA and HFB) Product Usage:ProBeam Proton Therapy System provides protons for precision radiotherapy of lesions, tumors, and conditions anywhere in the body. where radiation treatment is indicated.

FDA Enforcement
Class II ·Terminated·VARIAN MEDICAL SYSTEMS PARTICLE THERAPY GMBH·July 2, 2014

HEB Wound Closure Adhesive Surgical Tape Strips 30 strips 1/4 in. x 4 in. Sterile latex free UPC # 041220302536 Used to secure, close and support small cuts and wounds.

FDA Enforcement
Class II ·Terminated·ASO, LLC·August 14, 2013

UniCel DxH 600 COULTER Cellular Analysis System, configured with the Led HGB Photometer REF:B23858

FDA Enforcement
Class II ·Ongoing·Beckman Coulter Inc.·September 24, 2025

UniCel DxH 690T COULTER Cellular Analysis System, configured with the Led HGB Photometer REF: C34520

FDA Enforcement
Class II ·Ongoing·Beckman Coulter Inc.·September 24, 2025

UniCel DxH 900 COULTER Cellular Analysis System, configured with the Led HGB Photometer REF: C11478

FDA Enforcement
Class II ·Ongoing·Beckman Coulter Inc.·September 24, 2025

UniCel DxH 800 COULTER Cellular Analysis System, configured with the Led HGB Photometer REFs:B24802, 629029, B63322

FDA Enforcement
Class II ·Ongoing·Beckman Coulter Inc.·September 24, 2025

RNA MEDICAL, QCHGB HEMOGLOBIN CONTROL, MULTI, REF QC HGB - Product Usage: monitoring the performance of Hemocue Hemoglobin Analyzers. It provides a convenient method of performing periodic QC checks to verify correct system measurement.

FDA Enforcement
Class II ·Terminated·Medline Industries Inc·March 24, 2021

cobas m 511 integrated hematology analyzer, Model Number 07261691190 Product Usage: The cobas m 511 integrated hematology analyzer is a quantitative, automated analyzer with cell locating capability. It is intended for in vitro diagnostic use by a skilled operator in the clinical laboratory. The system prepares a stained microscope slide from EDTA anticoagulated whole blood. It utilizes computer imaging to count the formed elements of blood and provide an image-based assessment of cell morphology, which may be reviewed by the operator, and also allows for manual classification of unclassified cells. The instrument reports the following parameters: RBC, HGB, HCT, MCV, MCH, MCHC, RDW, RDW-SD, %NRBC, #NRBC, WBC, %NEUT, #NEUT, %LYMPH, #LYMPH, %MONO, #MONO, %EO, #EO, %BASO, #BASO, PLT, MPV, %RET, #RET, HGB-RET.

FDA Enforcement
Class II ·Terminated·Roche Diagnostics Hematology·August 1, 2018

BD Microtainer Tube w/ BD Microgard Closure, K2EDTA additive, Model Numbers 365974 and 365975 Product Usage: The Microtainer¿ Brand Tube with EDTA(K2) Reorder No. 365974, is used to collect, anticoagulate, transport and store skin puncture blood specimens for testing the following hematological parameters: WBC, RBC ,HGB, HCT, MCV, MCH, MCHC, Platelets, 5 part differential including : Neutrophils, Lymphocytes, Monocytes, Eosinophils, Basophils, Manual WBC Differentials, Reticulocytes, and Spun Hematocrit.

FDA Enforcement
Class II ·Terminated·Becton Dickinson & Company·July 24, 2019

pocH-100i; sysmex; Automated Hematology Analyzer; 7.3" x 13.8" x 18.1" / 30.8 lbs.; Sysmex Corporation; 1-5-1 Wakinohama-Kaigandori, Chuo-ku, Kobe 651-0073, Japan; Sysmex America, Inc; One Nelson C. White Pkwy, Mundeline, IL 60060, U.S.A. The Sysmex pocH-100i Automated Hematology Analyzer is an automated cell counter intended for in vitro diagnostic use in CLIA non-waived clinical laboratories (not for Point of Care use in a CLIA waived laboratory). The Complete Blood Cel (CBC) count test parameters include: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, and NEUT%/#, LYMPH %/#, MIXED %/# (EO, BSO, MONO).

FDA Enforcement
Class II ·Terminated·Sysmex America Inc·November 6, 2013

The Sight OLO device is a computer vision based platform for blood analysis. The platform combines computer-vision algorithms for image processing to identify and quantify blood components (e.g., red blood cells) and their characteristics (e.g., cell volume) in an automated fashion. Using dedicated staining, the proposed platform provides complete blood count analysis. The Sight OLO is a compact device, designed to be automated and simple to operate, to enable rapid testing and analysis. The Sight OLO consists of a scanning and analyzing device and a CBC test kit, including disposable cartridges and sample preparation tools. The disposable cartridge containing the blood sample is loaded into the device through the loading slot. The device is operated through the touch screen interface. The Sight OLO provides complete blood count information with 5-part differentials for white blood cell types. Specifically, the CBC parameters measured by the Sight OLO are listed below and include: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, PLT, NEUT%/#, LYMPH %/#, MONO %/#, EO%/# and BASO%/#. In addition, the Sight OLO signals specific WBC abnormal cases by flagging the sample.

FDA Enforcement
Class II ·Ongoing·SIGHT DIAGNOSTICS LTD·April 27, 2022

Synthes External Fixation System Tube to Tube Clamp, Part Number 390.007. Intended for use to provide treatment for long bone and pelvic fractures that require external fixation. Specifically, the components can be used for: Stabilization of soft tissues and fractures; Polytrauma/multiple orthopedic trauma; Vertically stable pelvic fractures, or as treatment adjunct for vertically unstable pelvic fractures; Arthrodeses and osteotomies with soft tissue problems - failures of total joints; Neutralization of fractures stabilized with limited internal fixation; Non-unions/septic non-unions; Intra-operative reductions/stabilization tool to assist with indirect reduction; and Unilateral rectilinear bone segment transport or leg lengthening.

FDA Enforcement
Class II ·Terminated·Synthes USA HQ, Inc.·November 21, 2012

Synthes Titanium Trochanteric Fixation Nail (TFN)-Helical Blade Synthes Titanium Trochanteric Fixation Nail (TFN)-Helical Blade is used to treat stable and unstable fractures of the proximal femur including pertrochanteric fractures, intertrochanteric fractures, basal neck fractures, and combinations thereof. The long TFN is additionally indicated for subtrochanteric fractures, pertrochanteric fractures associated with shaft fractures, pathologic fractures (including prophylactic use) in both trochanteric and diaphyseal regions, long subtrochanteric fractures, proximal or distal non-unions, malunions, and revisions.

FDA Enforcement
Class II ·Terminated·Synthes USA HQ, Inc.·November 27, 2013

Synthes Trauma Nail System. The devices are indication for bone fixation.

FDA Enforcement
Class II ·Terminated·Synthes USA HQ, Inc.·September 4, 2013

Flexible Grip which is part of the Synthes Universal Nail System. Indicated for the conventional (non-locking) technique of treating stable diaphyseal fractures.

FDA Enforcement
Class II ·Terminated·Synthes USA HQ, Inc.·April 17, 2013

4.5mm TI Multiloc Screw Length 38MM-Sterile Expiration: 04/29/2012 REF 04.019.038S Manufactured or Distributed by Synthes (USA) 1101 Synthes Avenue, Monument CO 80132 4.5MM TI Multiloc Screw Length 38MM-Sterile Ref 04.019,038S. The Multiloc Screw 4.5 is used with a Multiloc PHN for treatment of proximal humerus fractures and is intended to be inserted through the Multiloc PHN until it engages the subchondral bone below the relative distal cortex (cortex closest to the humeral head, below the articular surface).

FDA Enforcement
Class II ·Terminated·Synthes USA HQ, Inc.·August 1, 2012

Synthes Trochanteric Fixation Nail As part of the Synthes Trochanteric Fixation Nail (TFN) System, the TFN Nail is intended to treat stable and unstable fractures of the proximal femur.

FDA Enforcement
Class II ·Terminated·Synthes USA HQ, Inc.·December 18, 2013

Synthes Soft Tissue Retractor Small Extendible Offset blade facilitates easy preparation of the epipereosteal cavity for percutaneous plate insertion.

FDA Enforcement
Class II ·Terminated·Synthes USA HQ, Inc.·November 27, 2013