2,277 results
·
22ms
·
Sources: EU EUDAMED, US FDA
Filters
FDA Recall
×
OsteoStim Cervical Allograft (Lordotic Cervical Spacer) H. 7mm; W. 14mm; L. 10mm., Catalog Number: 45-5537 and Catalog Number : LGAL906, Distributed by EBI. (dba Biomet Spine, Biomet Trauma, Biomet Bracing, Biomet Osteobiologics) Parsippany, New Jersey 07054
FDA Recall
Terminated
·Product code MQV·October 23, 2007
BIOMET 3i LOCATOR ABUTMENT, Catalog/Item Number: LOA002, 2.0mm, BioMet 3i, Palm Beach, FL.
FDA Recall
Terminated
·Biomet 3i, Inc.·Product code DZE·February 7, 2008
BIOMET 3i LOCATOR ABUTMENT, Catalog/Item Number: LOA003, 3.0mm, BioMet 3i , Palm Beach, FL.
FDA Recall
Terminated
·Biomet 3i, Inc.·Product code DZE·February 7, 2008
Biomet --DCM AGC Molded Tibial Implant (12 mm x 80 mm)--Biomet Orthopedics , Interlok finish/posterior stabilized, 12 mm thick x 80 mm wide, UHMWPE/CO-CR-MO alloy, sterile; REF 155364, Biomet Orthopedic, Inc.
FDA Recall
Terminated
·Biomet, Inc.·Product code JWH·July 24, 2007
Biomet 8.0MM cannulated reamer for the Aimer system, Biomet Sports Medicine, Ontario, CA; REF 909618.
FDA Recall
Terminated
·Biomet, Inc.·Product code HWE·August 6, 2009
Biomet CC Cruciate Tibial Tray, 67 mm.; Product No. 141232, Biomet, Inc., Warsaw, IN 46581
FDA Recall
Terminated
·Biomet, Inc.·Product code JWH·December 12, 2007
Biomet CC Cruciate Tibial Tray, 75 mm.; Product No. 141234, Biomet, Inc., Warsaw, IN 46581
FDA Recall
Terminated
·Biomet, Inc.·Product code JWH·December 12, 2007
Biomet RINGLOC + Instrumentation Impactor Plate, Size 21; REF 31-400621,Biomet Orthopedics, Inc., Warsaw, IN.
FDA Recall
Terminated
·Biomet, Inc.·Product code LXH·October 18, 2007
Biomet RINGLOC + Instrumentation Impactor Plate, Size 28; REF/Part#: 31-400628, Biomet Orthopedics, Inc., Warsaw, IN.
FDA Recall
Terminated
·Biomet, Inc.·Product code LXH·October 18, 2007
Biomet RINGLOC + Instrumentation Impactor Plate, Size 20; REF/Part #: 31-400620, Biomet Orthopedics, Inc., Warsaw, IN.
FDA Recall
Terminated
·Biomet, Inc.·Product code LXH·October 18, 2007
Biomet RINGLOC + Instrumentation Impactor Plate, Size 26; REF/Part#: 31-400626, Biomet Orthopedics, Inc., Warsaw, IN.
FDA Recall
Terminated
·Biomet, Inc.·Product code LXH·October 18, 2007
Biomet RINGLOC + Instrumentation Impactor Plate, Size 22; REF/Part#: 31-400622, Biomet Orthopedics, Inc., Warsaw, IN.
FDA Recall
Terminated
·Biomet, Inc.·Product code LXH·October 18, 2007
Biomet RINGLOC + Instrumentation Impactor Plate, Size 23; REF/Part#: 31-400623, Biomet Orthopedics, Inc., Warsaw, IN.
FDA Recall
Terminated
·Biomet, Inc.·Product code LXH·October 18, 2007
Biomet Optigun Cement Gun, non-sterile; REF 419300 and REF 4193 (in Europe), Biomet, Inc., Warsaw, IN
FDA Recall
Terminated
·Biomet, Inc.·Product code LXH·September 21, 2007
Biomet 3i, Certain PreFormance Temporary Cylinder, Catalog Number: IPFTC42, Dental Implant, Biomet 3i, Palm Beach Gardens, FL 33410
FDA Recall
Terminated
·Product code NHA·October 8, 2007
Biomet Optigun Cement Gun, Ratchet, non-sterile; REF 419500 and REF 4195 (in Europe), Biomet, Inc., Warsaw, IN
FDA Recall
Terminated
·Biomet, Inc.·Product code LXH·September 21, 2007
Sonogage EyeScan, A-Scan Biometer, Product Usage: A-Scan Biometer diagnostic device for measurement of axial eye length.
FDA Recall
Terminated
·Sonogage Inc·Product code IYO·August 9, 2013
Biomet bone mulch screw, 10.5mm x 20 mm, TI-6AL-4V alloy, sterile, Biomet Sports Medicine, Warsaw, IN; REF 907320.
FDA Recall
Terminated
·Biomet, Inc.·Product code HWC·December 22, 2009
Biomet Vanguard DCM CR Tibial Bearing, 18MM x 71/75MM, CR STD bearing, sterile, Biomet Orthopedics, Inc., Warsaw, IN; Part 183448.
FDA Recall
Terminated
·Biomet, Inc.·Product code JWH·February 12, 2008
Biomet Vanguard DCM CR Tibial Bearing, 14MM x 79/83MM, CR STD bearing, sterile, Biomet Orthopedics, Inc., Warsaw, IN; Part 183464.
FDA Recall
Terminated
·Biomet, Inc.·Product code JWH·February 12, 2008