Baxter prismaflex, HF 1000 PAES membrane, REF 107140 Used with Prismaflex or PrisMax control units for continuous fluid management and renal replacement therapies.

FDA Recall
Terminated ·Baxter Healthcare Corporation·Product code KDI·July 22, 2021

VORTRAN Automatic Resuscitator, VARPlus with Extension Kit; Model PCE-5012; Qty: 10 each. Anesthesiology: This device is to be used by properly trained personnel to deliver emergency, short term, constant flow, pressure cycled ventilatory support.

FDA Recall
Terminated ·Vortran Medical Technology 1, Inc·Product code BTL·April 20, 2017

Hamilton brand Disposable Syringe Pack for use with Microlab F.A.M.E; Part Number: 147692 (case containing 96 syringes); Manufactured by: Treff AG, Degersheim, Switzerland for Hamilton Bonaduz AG, Bonaduz, Switzerland (Manufacturer of record); Product is distributed by Hamilton Company, Reno, NV The F.A.M.E Syringes are a disposable product that is used on our Microlab F.A.M.E. series instruments for diluting/dispensing. Microlab F.A.M.E was released under 510(k) K943493/S1 under product codes JJE (862.2160 Discrete Photometric Chemistry Analyzer for Clinical Use), JJQ (862.2300 Colorimeter, photometer, or spectrophotometer for Clinical Use), and JTC (866.2500 Microtiter Diluting/Dispensing Device), all of which are currently Class I exempt devices. The syringes are also used on Ortho Summit Processor instruments distributed by Ortho-Clinical Diagnostics.

FDA Recall
Terminated ·Hamilton Co·Product code JJE·September 26, 2011

Invacare PerfectO2 V Oxygen Concentrator- intended for patients with respiratory disorders requiring supplemental oxygen Model Numbers: IRC5PO2V (US), IRC5PO2VC (Canada), All World: IRC5PO2VAW, IRC5PO2VAWL2, IRC5PO2VAWL3, IRC5PO2VAWL4, IRC5PO2VAWL5

FDA Recall
Terminated ·Invacare Corporation·Product code CAW·October 30, 2020

Torrent Suite Dx Software Version 5.8 Catalog Number:A36601 and A36602 OEM Customer software: Torrent Suite Dx T430 Software v5.0 DARUI DR-SEQ 800 Software UDI:(01)10190302014090 (11)000000(10)5.8 (240)A36601

FDA Recall
Terminated ·Life Technologies Holdings Pte Ltd Blk·Product code PFF·September 26, 2019

Torrent Suite Dx Software Version (IUO) 5.2 Catalog Number: A29225 OEM Customer Software: Sentosa SQ Suite Software v5.6.9

FDA Recall
Terminated ·Life Technologies Holdings Pte Ltd Blk·Product code PFF·September 26, 2019

Torrent Suite Dx Software Version 5.6.4 Catalog Number:A33178 OEM Customer software: Sentosa SQ Suite Software v5.6.20 UDI: (01)10190302005654 (11)000000 (10)5.6.4 (240)A33178

FDA Recall
Terminated ·Life Technologies Holdings Pte Ltd Blk·Product code PFF·September 26, 2019

Torrent Suite Dx Software Version (IUO) 5.4 Catalog Number: A31774 OEM Customer Software: Sentosa SQ Suite Software v5.6.15

FDA Recall
Terminated ·Life Technologies Holdings Pte Ltd Blk·Product code PFF·September 26, 2019

TRYPTIK(R) 2 C-PLATE SELF-TAPPING POLYAXIAL SCREW 4.5 MM, LENGTH 12 MM, REF TRY-PS-45 12-S, Qty 2 TRYPTIK(R) 2C-Plate Anterior Cervical Plate System is intended to be used for temporary stabilization of the cervical spine (C2-C7) during the development of solid spinal fusion in patients with instability caused by the following degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), trauma (including fractures), tumor, spondylolisthesis, spinal stenosis, deformity (i.e., scoliosis, kyphosis, lordosis), pseudarthrosis, and failed previous fusions.

FDA Recall
Terminated ·SPINEART SA route de Pre bois 20 Case Postale·Product code KWQ·November 27, 2017

TRYPTIK(R) 2 C-PLATE SELF-TAPPING POLYAXIAL SCREW 4.0 MM, LENGTH 16 MM, REF TRY-PS-40 16-S, Qty 2 TRYPTIK(R) 2C-Plate Anterior Cervical Plate System is intended to be used for temporary stabilization of the cervical spine (C2-C7) during the development of solid spinal fusion in patients with instability caused by the following degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), trauma (including fractures), tumor, spondylolisthesis, spinal stenosis, deformity (i.e., scoliosis, kyphosis, lordosis), pseudarthrosis, and failed previous fusions.

FDA Recall
Terminated ·SPINEART SA route de Pre bois 20 Case Postale·Product code KWQ·November 27, 2017

TRYPTIK(R) 2 C-PLATE SELF-TAPPING POLYAXIAL SCREW 4.0 MM, LENGTH 14 MM, REF TRY-PS-40 14-S, Qty 2 TRYPTIK(R) 2C-Plate Anterior Cervical Plate System is intended to be used for temporary stabilization of the cervical spine (C2-C7) during the development of solid spinal fusion in patients with instability caused by the following degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), trauma (including fractures), tumor, spondylolisthesis, spinal stenosis, deformity (i.e., scoliosis, kyphosis, lordosis), pseudarthrosis, and failed previous fusions.

FDA Recall
Terminated ·SPINEART SA route de Pre bois 20 Case Postale·Product code KWQ·November 27, 2017

TRYPTIK(R) 2 C-PLATE SELF-TAPPING POLYAXIAL SCREW 4.5 MM, LENGTH 14 MM, REF TRY-PS-45 14-S, Qty 2 TRYPTIK(R) 2C-Plate Anterior Cervical Plate System is intended to be used for temporary stabilization of the cervical spine (C2-C7) during the development of solid spinal fusion in patients with instability caused by the following degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), trauma (including fractures), tumor, spondylolisthesis, spinal stenosis, deformity (i.e., scoliosis, kyphosis, lordosis), pseudarthrosis, and failed previous fusions.

FDA Recall
Terminated ·SPINEART SA route de Pre bois 20 Case Postale·Product code KWQ·November 27, 2017

TRYPTIK(R) 2 C-PLATE SELF-TAPPING POLYAXIAL SCREW 4.5 MM, LENGTH 18 MM, REF TRY-PS-45 18-S, Qty 2 TRYPTIK(R) 2C-Plate Anterior Cervical Plate System is intended to be used for temporary stabilization of the cervical spine (C2-C7) during the development of solid spinal fusion in patients with instability caused by the following degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), trauma (including fractures), tumor, spondylolisthesis, spinal stenosis, deformity (i.e., scoliosis, kyphosis, lordosis), pseudarthrosis, and failed previous fusions.

FDA Recall
Terminated ·SPINEART SA route de Pre bois 20 Case Postale·Product code KWQ·November 27, 2017

TRYPTIK(R) 2 C-PLATE SELF-TAPPING POLYAXIAL SCREW 4.0 MM, LENGTH 12 MM, REF TRY-PS-40 12-S, Qty 2 TRYPTIK(R) 2C-Plate Anterior Cervical Plate System is intended to be used for temporary stabilization of the cervical spine (C2-C7) during the development of solid spinal fusion in patients with instability caused by the following degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), trauma (including fractures), tumor, spondylolisthesis, spinal stenosis, deformity (i.e., scoliosis, kyphosis, lordosis), pseudarthrosis, and failed previous fusions.

FDA Recall
Terminated ·SPINEART SA route de Pre bois 20 Case Postale·Product code KWQ·November 27, 2017

TRYPTIK(R) 2 C-PLATE SELF-TAPPING POLYAXIAL SCREW 4.5 MM, LENGTH 16 MM, REF TRY-PS-45 16-S, Qty 2 TRYPTIK(R) 2C-Plate Anterior Cervical Plate System is intended to be used for temporary stabilization of the cervical spine (C2-C7) during the development of solid spinal fusion in patients with instability caused by the following degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), trauma (including fractures), tumor, spondylolisthesis, spinal stenosis, deformity (i.e., scoliosis, kyphosis, lordosis), pseudarthrosis, and failed previous fusions.

FDA Recall
Terminated ·SPINEART SA route de Pre bois 20 Case Postale·Product code KWQ·November 27, 2017

PERLA TL Lateral Connector Open - Product Usage: intended to be used with autograft and/or allograft. Pediatric pedicle screw fixation is limited to a posterior approach. Models: PERLA TL Lateral Connector Open, 15mm PERLA TL Lateral Connector Open, 30mm

FDA Recall
Terminated ·SPINEART SA Chemin Du Pre-Fleuri 3 Plan-Les-Ouates Switzerland·Product code NKB·April 9, 2021

Intersomatic JULIET Ti OL cage. For use in orthopedic spinal procedures

FDA Recall
Terminated ·SPINEART SA Chemin Du Pre-Fleuri 3 Plan-Les-Ouates Switzerland·Product code MAX·February 5, 2019

Osteopore PCL Scaffold Bone Filler: Osteopore Osteoplug-C, Osteoplug, and Osteomesh.

FDA Recall
Terminated ·OSTEOPORE INTERNATIONAL PTE LTD 10, SCIENCE PARK ROAD THE ALPHA, #02-28 SINGAPORE Singapore·Product code GXP·April 27, 2011

Roche brand OMNI 9 clinical chemistry analyzer; catalog numbers GD0475, GD0475R and GD047591.

FDA Recall
Terminated ·Roche Diagnostics Corp.·Product code JJE·December 15, 2003

SYNCHRON CX4 Delta Clinical System Part #: 468233 Product Usage: The Beckman SYNCHRON CX4 DELTA, CX7 DELTA, CX4CE, and CX7 systems are fully automated and computer controlled instruments designed for the in vitro diagnostic quantitation of biological fluid components and therapeutic drugs as well as the qualitative determination of drugs of abuse in urine

FDA Recall
Terminated ·Beckman Coulter Inc.·Product code JJE·August 23, 2010