BD Nexiva, 20 GA 1.00 IN (1.1 X 25 mm), 3660 ml/hr. 61ml/min; Closed IV Catheter System- Dual port -61 mL/min (3660 mL/hr)-0.5mL, REF 383536; BD Q-Style Luer Access Split Septum BD Vialon Material; BD Instaflash Needle Technology; Rx Only, Sterile EO. BD Nexiva closed IV catheter systems are over-the-needle, intravascular catheters. These devices have a radiopaque BD Vialon" catheter, needle, needle shield, septum, stabilization platform, integrated extension tubing, clamp, dual port adapter, vent plug and pre-attached BD Q-Syte Luer Access Split Septum. The needle and catheter are protected by a needle cover. A BD Q-Syte device or an end cap with protective cover is provided in the unit package. The closed system is designed to keep blood contained within the device throughout the insertion process. The septum is designed to wipe visible blood from the needle surface as the needle is withdrawn from the catheter, further reducing the risk of blood exposure. The needle tip is passively protected when the needle is removed, reducing the risk of accidental needlestick injury. These devices have BD Instaflash" Needle Technology, allowing for immediate visualization of blood along the catheter. Continuous blood return is seen in the extension tubing. The vent plug prevents blood leakage from the extension tubing during insertion. Both the stabilization platform and dual port adapter are color coded to indicate catheter gauge size (24GA (0.7 mm)=Yellow, 22GA (0.9 mm)=Blue, 20GA (1.1 mm)=Pink, 18GA (1.3 mm)=Green). BD Nexiva closed IV catheter systems are intended to be inserted into a patient s vascular system for short term use to sample blood, monitor blood pressure, or administer fluids. These catheters may be used for any patient population with consideration given to adequacy of vascular anatomy, procedure being performed, fluids being infused, and duration of therapy. The 22-18GA (0.9-1.3 mm) devices are suitable for use with power injectors set to a maximum pressure of 300 psi (2068 kPa) when access ports not suitable for use with power injectors are removed.
FDA Recall
Open, Classified
·Becton Dickinson Infusion Therapy Systems Inc.·Product code FOZ·September 8, 2021
ECONO STERILE medical procedure kits labeled as: 1) ECONO STERILE HEGAR DILATOR 11&12MM STRLCS25Model Number 96-0960; 2) ECONO STERILE HEGAR DILATOR 9&10MM STRL CS25Model Number 96-0961; 3) ECONO STERILE HEGAR DILATOR 7&8MM STRL CS25Model Number 96-0962; 4) ECONO STERILE HEGAR DILATOR 5&6MM STERL CS25Model Number 96-0963; 5) ECONO STERILE HEGAR DILATOR 3&4MM STERL CS25Model Number 96-0964; 6) ECONO STERILE HEGAR DILATOR 1&2MM STERL CS25Model Number 96-0965; 7) ECONO STERILE HANK DILATOR 5.5&6MM STRL CS25Model Number 96-0966; gynecological dilators
FDA Recall
Open, Classified
·Sklar Instruments·Product code HDQ·December 3, 2024
Centurion Manual surgical kits labeled as: a) HEGAR UTERINE DILATOR, 11-12MM, STERILE, Product Code HUD112ST; b) STERILE UTERINE DILATOR 1MM/2MM, Product Code HUD12ST; c) HEGAR UTERINE DILATOR, 5-6MM, STERILE, Product Code HUD56ST; d) HEGAR UTERINE DILATOR, 9-10MM, STERILE, Product Code HUD910ST; e) HANK UTERINE DILATOR 11" 7/8FR STERILE, Product Code I68920; f) HANK UTERINE DILATOR 11" 13/14FR STERILE, Product Code I68930
FDA Recall
Open, Classified
·MEDLINE INDUSTRIES, LP Northfield·Product code HDQ·February 23, 2024
ADVIA Chemistry Iron_2 (IRON_2) Reagents, Material Numbers 10377510 (6 x 350 tests) and 10341118 (7 x 145 tests)
FDA Recall
Open, Classified
·Siemens Healthcare Diagnostics, Inc.·Product code CDQ·August 8, 2023
Randox RX Series Urea Enzymatic Kinetic Assay Ref. Numbers: (1) UR3825 (2) UR3873 (3) UR8334 (4) UR8070 (Modena)
FDA Recall
Open, Classified
·Randox Laboratories Ltd.
55 Diamond Road
Crumlin (North) Ireland·Product code CDQ·June 13, 2023