7 results · 17ms · Sources: EU EUDAMED, US FDA

Get notified when this changes

We'll email you when new records match this search — new devices, new clearances, certificate changes, or withdrawals.

TB Series Bipolar Pacing Leads, French Size 4F, 5F, 6F for Curve Type Straight, Atrial J, 60 degree Curve, and Right Heart. TB is packaged for sterile single use in a double tray. The lead is placed in a PETG inner tray that is sealed with a Tyvek inner lid. The sealed inner tray is placed in an outer PETG tray. The outer tray is sealed with an outer Tyvek lid. An inner label is placed on the outer Tyvek lid. The sealed trays are placed in a labeled white shelf box with on Instruction for use. Packed on lead per outer white shelf box.

FDA Enforcement
Class I ·Terminated·Oscor, Inc.·November 14, 2018

VERSYS 6 INCH BEADED FC 1 VERSYS 6 INCH BEADED FC S VERSYS 8 INCH BEADED FC 1 VERSYS 8 INCH BEADED FC 2 prosthesis, hip, semi-constrained, metal/polymer, porous uncemented "" Total hip replacement for the following: severe hip pain and disability due to rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, avascular necrosis of the femoral head, nonunion of previous fractures of the femur; congenital hip dysplasia, protrusio acetabuli, slipped capital femoral epiphysis; disability due to previous fusion; previously failed endoprostheses, and/or total hip components in the affected extremity and acute femoral neck fractures. " Hemi-hip replacement for the following: fracture dislocation of the hip; elderly, debilitated patients when a total hip replacement is contraindicated; irreducible fractures in which adequate fixation cannot be obtained; certain high subcapital fractures and comminuted femoral neck fractures in the aged; nonunion of femoral neck fractures; secondary avascular necrosis of the femoral head; pathological fractures of the femoral neck; and osteoarthritis in which the femoral head is primarily affected."

FDA Enforcement
Class II ·Terminated·Zimmer Biomet, Inc.·March 2, 2016

Ergon 2 Articulating Equipment Boom Monitor Brackets mounting point for display interfaces utilized in clinical applications for viewing purposes and to provide an articulating point of movement on the ceiling mounted radial arm suspension system of the Ergon 2 equipment pendant / booms

FDA Enforcement
Class II ·Terminated·Skytron, Div. The KMW Group, Inc·January 20, 2016

VERSYS 6 INCH BEADED FC 1 prosthesis, hip, semi-constrained, metal/polymer, porous uncemented "" Total hip replacement for the following: severe hip pain and disability due to rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, avascular necrosis of the femoral head, nonunion of previous fractures of the femur; congenital hip dysplasia, protrusio acetabuli, slipped capital femoral epiphysis; disability due to previous fusion; previously failed endoprostheses, and/or total hip components in the affected extremity and acute femoral neck fractures. " Hemi-hip replacement for the following: fracture dislocation of the hip; elderly, debilitated patients when a total hip replacement is contraindicated; irreducible fractures in which adequate fixation cannot be obtained; certain high subcapital fractures and comminuted femoral neck fractures in the aged; nonunion of femoral neck fractures; secondary avascular necrosis of the femoral head; pathological fractures of the femoral neck; and osteoarthritis in which the femoral head is primarily affected."

FDA Enforcement
Class II ·Terminated·Zimmer Biomet, Inc.·March 2, 2016

VERSYS 6 INCH BEADED FC 1 prosthesis, hip, semi-constrained, metal/polymer, porous uncemented "" Total hip replacement for the following: severe hip pain and disability due to rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, avascular necrosis of the femoral head, nonunion of previous fractures of the femur; congenital hip dysplasia, protrusio acetabuli, slipped capital femoral epiphysis; disability due to previous fusion; previously failed endoprostheses, and/or total hip components in the affected extremity and acute femoral neck fractures. " Hemi-hip replacement for the following: fracture dislocation of the hip; elderly, debilitated patients when a total hip replacement is contraindicated; irreducible fractures in which adequate fixation cannot be obtained; certain high subcapital fractures and comminuted femoral neck fractures in the aged; nonunion of femoral neck fractures; secondary avascular necrosis of the femoral head; pathological fractures of the femoral neck; and osteoarthritis in which the femoral head is primarily affected."

FDA Enforcement
Class II ·Terminated·Zimmer Biomet, Inc.·March 2, 2016

Brand: The ForeCYTE Breast Health Test, Mammary Aspiration Specimen Cytology Test (MASCT), MASCT System Kits, Clarity System Kits, MASCT Patient Sample Kits & Clarity Patient Sample Kits Instrument, Biopsy. The MASCT System Kit, Patient Sample Kits, or the Nipple Aspirate Fluid Laboratory Kit has the following codes: PRODUCT CODE: AG-MASCT; AG-FC5; DTG-MASCT, DTG-FC5, and NRLBH-5. PART NUMBER: 9002513; 9002513MD; 9002528; 9002528MD; 9002587; 9002614; and 9002717MD. THE MASCT SYSTEM KIT CONSISTS OF: 1. MASCT Breast Pump; 2. Instructions for Use (IFU); 3. Heating Pad; 4. Timer; 5. Saccomono's Fixative; 6. Nu Prep Gel; 7. Welcome and Training Materials Coversheet; 8. MASCT System Order Form; 9. ForeCYTE Training Video DVD; 10. MASCT System Instructions with pictures - pink; THE PATIENT SAMPLE KIT CONSISTS OF: 1. Two (2) flower assemblies (e.g., filter, filter retainer, and filter holder); 2. Instructions for Use (IFU); 3. Two (2) specimen collection devices; 4. Two (2) breast bags for transporting the specimen collection container; 5. Barcode labels; 6. Saccomono's Fixative; 7. Nu Prep Gel; 8. MASCT System package insert; 9. ForeCYTE Test Requisition Form; 10. Patient Information Sheet; 11. Atossa Patient Information; 12. FED EX Clinical PAK; 13. MASCT System Order Form; 14. FED EX Pouch; 15. FED EX Airbill; Product Usage: The MASCT Device is intended for use in the collection of nipple aspirate fluid for cytological testing. The collected fluid can be used in the determination and/or differentiation of normal versus premalignant versus malignant cells.

FDA Enforcement
Class I ·Terminated·Atossa Genetics, Inc.·November 6, 2013

Beacon Tip Torcon NB Advantage Catheter Catheter, Intravascular, Diagnostic

FDA Enforcement
Class II ·Terminated·Cook Inc.·August 31, 2016