4 results
·
7ms
·
Sources: EU EUDAMED, US FDA
MultiDiagnost-Eleva, Product codes 708032, 708036 Product Usage: As a multifunctional I universal imaging application system, General RIF, Fluoroscopy, Radiography and Angiography can be performed along with more specialized interventional applications on human patients. This includes the following general areas: Digestive system: Swallowing studies, Oesophagus, Stomach, Small intestine, Colon, Defeacography, ERCP, T-tube cholangiogram, Liver biopsies, Transjugular Intrahepatic Portosystemic Shunts (TIPS) Skeletal system: Bone studies. Urinary system: IVP, Cystograms, Percutaneous, Nephrolithotomy, Nephrostomy tube replacement Reproductive system: Hysterosalpingogram, Vena spermatica, Cavernography Respiratory system: Thorax, Bronchoscopy, Pulmonary biopsies Circulatory system: Venography, Arteriography, Thrombolytic Therapy, Em bolizations, Em bolectomy, IVC filter placement, Dilatations, Stent placement. Various: Arthrograms, Myelograms, Facet joint injections, Discography, Sialography.
FDA Enforcement
Class II
·Terminated·Philips North America, LLC·April 3, 2019
Omnidiagnost Classic, Product Codes 70859, 708023, 708024, 708025 Product Usage: The Philips OmniDiagnost is a multi-functional, universal X-ray system with remote-controlled facilities. It performs a wide range of routine examinations and interventional procedures include: Gastro-intestinal examination Urography Bronchography Arthrography Hysterography Myelography Lymphography Skeletal radiography Tomography Venography/phlebography Special procedures that require subtracted and non-subtracted digital imaginginclude: Angiography Peripheral angiography (bolus chasing) Vascular and non-vascular interventional procedures.
FDA Enforcement
Class II
·Terminated·Philips North America, LLC·April 3, 2019
Philips Allura Xper Interventional Fluoroscopic X-ray Systems, specifically the Disk Bay of the PC component of affected systems. Affected PCs: FlexVision PC Allura Xper Model Name - Model Number: Allura Xper FD10 722003 722010 722026; Allura Xper FD10/10 722005 722011 722027; Allura Xper FD20 722006 722012 722028; Allura Xper FD20 Biplane 722008 722013; Allura Xper FD20 Biplane OR Table 722025; Allura Xper FD20 OR Table 722023 722035; Allura Xper FD20/10 722029; Allura Xper FD20/15 722058; Allura Xper FD20/15 OR Table 722059; Allura Xper FD20/20 722038; Allura Xper FD20/20 OR Table 722039;
FDA Enforcement
Class II
·Ongoing·PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.·February 28, 2024
Philips Allura Xper Interventional Fluoroscopic X-ray Systems, specifically the Disk Bay of the PC component of affected systems. Affected PCs: Imaging Processing PC, Host PC, FlexVision PC Allura Xper Model Name - Model Number: Allura Xper FD10 722003 722010 722026; Allura Xper FD10 OR Table 722022; Allura Xper FD10/10 722005 722011 722027; Allura Xper FD10C 722001; Allura Xper FD20 722006 722012 722028; Allura Xper FD20 Biplane 722008 722013; Allura Xper FD20 Biplane OR Table 722025; Allura Xper FD20 OR Table 722023 722035; Allura Xper FD20/10 722029; Allura Xper FD20/15 722058; Allura Xper FD20/15 OR Table 722059; Allura Xper FD20/20 722038; Allura Xper FD20/20 OR Table 722039; (Allura Centron - 722400 is impacted by this recall, but Allura Centron systems are not distributed in the United States.)
FDA Enforcement
Class II
·Ongoing·PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.·February 28, 2024