8 results
·
8ms
·
Sources: EU EUDAMED, US FDA
ErgoStar CM 55, Model/Catalog Number: MP01855, Airway connector for conduction of respiratory gases between the breathing system and the patient interface. (e.g. endotracheal tube mask) of a mechanically ventilated patient.
FDA Enforcement
Class I
·Ongoing·Draeger, Inc.·December 17, 2025
ErgoStar CM 45, Model/Catalog Number: MP01845, Airway connector for conduction of respiratory gases between the breathing system and the patient interface. (e.g. endotracheal tube mask) of a mechanically ventilated patient.
FDA Enforcement
Class I
·Ongoing·Draeger, Inc.·December 17, 2025
ErgoStar CM 60, Model/Catalog Number: MP01860, Airway connector for conduction of respiratory gases between the breathing system and the patient interface. (e.g. endotracheal tube mask) of a mechanically ventilated patient.
FDA Enforcement
Class I
·Ongoing·Draeger, Inc.·December 17, 2025
ErgoStar CM 40 Model/Catalog Number: MP01840 Airway connector for conduction of respiratory gases between the breathing system and the patient interface. (e.g. endotracheal tube mask) of a mechanically ventilated patient.
FDA Enforcement
Class I
·Ongoing·Draeger, Inc.·December 17, 2025
Beacon Tip 5.0 Fr Angiographic catheters are designed to facilitate diagnostic and therapeutic procedures. Catheters are available in various configurations. Configurations include different shaft lengths and tip curves and some catheters are manufactured with a hydrophilic coating. Refer to the product label for product specifications (e.g., catheter length, distal curve configuration).
FDA Enforcement
Class I
·Ongoing·Cook Incorporated·June 25, 2025
Centimeter Sizing Catheter RPN N5.0-35-100-P-10S-PIG-CSC-20 GPN G11916 Catheters for use in angiographic procedures are available in a variety of French sizes, endhole sizes, lengths, materials and designs (e.g., polyethylene or nylon, non-braided or braided with 1:1 torque). The choice of catheter material for different angiographic procedures should be based on the physician s experience.
FDA Enforcement
Class I
·Ongoing·Cook Incorporated·May 13, 2026
Greatbatch, Offset Cup Impactor with the following Parts and Catalogue #: Tl0600 ~ MMP3100CHA04 T10491 MIMP3100CHA04 T12230 M2M1P3100CHA04 T15752 ~MMP3100CHA04 T15949 ~MMP3100CHA04 T17238 MMP3100CHA04 T9954 MMP3100CHA04 T9955 MMP3100CHA04 T8468 MMP3100CHA04 T11506 MMP3100CHA13 T10281 MMP3100CHA04 T8044 ~MMP3100CHA04 T17203 87-4 20-00980 T8177 ~ MMP3100CHA04 T16934 MMP3100CHA62 Tll340 SHP9109.00010 T8043 ~ MMP3100CHA04 T17321 MMPP3100CHA04 T15311 GG920010029 T1 7650 255000110 T8143 803-t 1-103 Tl4384 EK-00200690 T1666t XEB227242 T9316 MIMP3100CHA04 Tl3642 500325 T10753 ~MMP3100CH04 T9348 ~ MMP3100CHA04 T13480 MMP3100CHA042 T10243 ~MIMP3001CHA08 Tll209 ~ MMP300CHA12 Tl0861 MMP3100CHA04 T16427 MMP3100CHA04 T9894 :-. MMP3100CHA04 T12861 MMP3100CHA\041 T8088 2002CUPI T1661 1 T16611 Standard Offset Cup Impactors are handheld, reusable surgical instruments used to position and seat acetabular cups into the reamed acetabulum during hip joint replacement surgery. They are equipped with a suitable connection system to the acetabular cup (e.g. a thread) and can be supplied with a fixed or removable shock absorber. A hammer is used to deliver the necessary impact to an anvil (or impactor disc) at the rear end of the instrument.
FDA Enforcement
Class I
·Terminated·Greatbatch Medical·December 7, 2016
Brand: The ForeCYTE Breast Health Test, Mammary Aspiration Specimen Cytology Test (MASCT), MASCT System Kits, Clarity System Kits, MASCT Patient Sample Kits & Clarity Patient Sample Kits Instrument, Biopsy. The MASCT System Kit, Patient Sample Kits, or the Nipple Aspirate Fluid Laboratory Kit has the following codes: PRODUCT CODE: AG-MASCT; AG-FC5; DTG-MASCT, DTG-FC5, and NRLBH-5. PART NUMBER: 9002513; 9002513MD; 9002528; 9002528MD; 9002587; 9002614; and 9002717MD. THE MASCT SYSTEM KIT CONSISTS OF: 1. MASCT Breast Pump; 2. Instructions for Use (IFU); 3. Heating Pad; 4. Timer; 5. Saccomono's Fixative; 6. Nu Prep Gel; 7. Welcome and Training Materials Coversheet; 8. MASCT System Order Form; 9. ForeCYTE Training Video DVD; 10. MASCT System Instructions with pictures - pink; THE PATIENT SAMPLE KIT CONSISTS OF: 1. Two (2) flower assemblies (e.g., filter, filter retainer, and filter holder); 2. Instructions for Use (IFU); 3. Two (2) specimen collection devices; 4. Two (2) breast bags for transporting the specimen collection container; 5. Barcode labels; 6. Saccomono's Fixative; 7. Nu Prep Gel; 8. MASCT System package insert; 9. ForeCYTE Test Requisition Form; 10. Patient Information Sheet; 11. Atossa Patient Information; 12. FED EX Clinical PAK; 13. MASCT System Order Form; 14. FED EX Pouch; 15. FED EX Airbill; Product Usage: The MASCT Device is intended for use in the collection of nipple aspirate fluid for cytological testing. The collected fluid can be used in the determination and/or differentiation of normal versus premalignant versus malignant cells.
FDA Enforcement
Class I
·Terminated·Atossa Genetics, Inc.·November 6, 2013