1,007 results
·
19ms
·
Sources: EU EUDAMED, US FDA
Filters
Status: Terminated
×
Medtronic DBS" 3389S-40 Lead Kit for Deep Brain Stimulation , length: 40 cm. Contents of the inner packages are Sterile and Non-Pyrogenic. Method of Sterilization: Ethylene Ox ide, Rx Only, Activa Therapy, Model 3387 Lead Kit Manufactured at : Medtronic, Inc., Villalba, Puerto Rico, STIMLOC Burr Hole Kit: Manufacturer: Medtronic Image-Guided Neurologics, Melbourne, FL 32935-3145 Implant manual: DBS" Leads: Proximal 40 mm, Distal 9.0 mm, Medtronic, Inc. Medtronic Active Therapy includes Activa Parkinson's Control Therapy and Activa Tremor Control Therapy. Parkinson's Control Therapy: Bilateral stimulation of the internal globus pallidus (GP) or the subthalamic nucleus (STN) using Medtronic Activa Parkinson's Control Therapy is indicated for adjunctive therapy in reducing some of the symptoms of advanced, levodopa-responsive Parkinson's disease that are not adequately controlled with medication. Tremor Control Therapy: Unilateral thalamic stimulation by the Medtronic Activa Tremor control system is indicated for the suppression of tremor in the upper extremity. The system is intended for using patients who are diagnosed with Essential Tremor or Parkinsonian tremor not adequately controlled by medications and where the tremor constitutes a significant functional disability.
FDA Recall
Terminated
·Medtronic Neuromodulation·Product code MHY·June 14, 2008
Medtronic, DBS Extension Kit for Deep Brain Stimulation, Catalog # 7482, 37085, 37086. Rx Only, Manufactured in: Medtronic, Inc. Villalba, Puerto Rico. Medtronic¿ DBSTM Therapy for Parkinson's Disease - Bilateral stimulation of the internal globus pallidus (GPi) or the subthalamic nucleus (STN) using Medtronic DBS Therapy for Parkinson's Disease is indicated for adjunctive therapy in reducing some of the symptoms of advanced, levodopa-responsive Parkinson's disease that are not adequately controlled with medication. STN/GPi target system components: ¿ Kinetra¿ Model 7428 or Soletra¿ Model 7426 Neurostimulator ¿ Activa¿ PC Model 37601, Activa RC Model 37612, Activa SC Model 37602, or Activa SC Model 37603 Neurostimulator ¿ Model 7482, Model 7482A, Model 7483, Model 37085, or Model 37086 Extension ¿ Model 3387 or Model 3389 Lead Medtronic DBS Therapy for Tremor - Unilateral thalamic stimulation of the ventral intermediate nucleus (VIM) using Medtronic DBS Therapy for Tremor is indicated for the suppression of tremor in the upper extremity. The system is intended for patients who are diagnosed with essential tremor or parkinsonian tremor not adequately controlled by medications and where the tremor constitutes a significant functional disability. VIM target system components: ¿ Soletra Model 7426 Neurostimulator ¿ Activa PC Model 37601, Activa RC Model 37612, Activa SC Model 37602, or Activa SC Model 37603 Neurostimulator ¿ Model 7482, Model 7482A, Model 7483, Model 37085, or Model 37086 Extension ¿ Model 3387 or Model 3389 Lead.
FDA Enforcement
Class II
·Terminated·Medtronic Neuromodulation·December 26, 2012
Remote Network Station, Catalog RNS-9703, Model No. RNS-9703-19, RNS-9703-24, Software version 02.40. The RNS 9703 is intended for use by medical professionals to provide secondary cardiac and vital signs monitoring for multiple patients within a medical facility. The device will display physiological data from up to 16 telemetry receiver/transmitters or bedside monitors and generate an alarm when a measured parameter falls outside a pre-set limit or when life threatening arrhythmias are detected.
FDA Enforcement
Class II
·Terminated·Nihon Kohden America Inc·May 6, 2015
CNSystems TASK FORCE MONITOR 3040i, plethysmograph, impedance. Noninvasively measure and display patient's hemodynamic parameters time synchronized using Impedance Cardiography (ICG), Electrocardiography (ECG), oscillometric Blood Pressure (oscBP) and continuous Blood Pressure (contBP). Furthermore Sympathic Tone and Parasympathic Tone are calculated by power spectral analysis of ECG (heart rate variability) and continuous blood pressure (blood pressure variability) as well as the Baroreceptor Reflex Sensitivity (BRRS). For use by medically trained personnel. It has been designed for diagnoses aiding and must not be used for vital sign monitoring of critically ill patients under absence of additional, suitable self-monitoring devices or medical trained personnel. The device measures continuously the subject's hemodynamic parameters without reporting any diagnosis. It is the physician's responsibility to make proper judgment based on these parameters.
FDA Enforcement
Class II
·Terminated·Partners In Medicine Llc·January 13, 2016
GlobTek, Inc. Power Supply for Medical Use Part No: TR9CE4000LCP-Y-MED MODEL: GTM21097-5012, Made in China. Indicated for patients who would benefit from a suction device particularly as the device may promote wound healing, including patients who would benefit from vacuum assisted drainage and removal of infectious materials or other fluid from wounds under the influence of continuous pressure.
FDA Recall
Terminated
·Smith And Nephew, Inc. Wound Management Division·Product code BTA·August 7, 2008
Aeroneb Go Micropump Nebulizer Featuring OnQ electronic micropump, RX, Manufactured by Medical Industries America Inc., Adel, IA. The product is sold individually or in master packs of 8 under the following model numbers (all using the same box label): Model 7000 - Consisting of the Aeroneb Go, battery controller, battery controller cable, 3 AA alkaline batteries, mask elbow, mouthpiece, carry bag, and user manual; Model 7030 - Consisting of the Aeroneb Go, AC wall adapter, mask elbow, mouthpiece, carry bag, and user manual; Model 7070 - Consisting of the Aeroneb Go, battery controller, battery controller cable, 3 AA alkaline batteries, AC wall adapter, mask elbow, mouthpiece, carry bag, and user manual; Model 7000-1 - Consisting of the Aeroneb Go, battery controller, battery controller cable, 3 AA alkaline batteries, European mask elbow, mouthpiece, carry bag, and user manual; Model 7030-1 - Consisting of the Aeroneb Go, AC wall adapter, European mask elbow, mouthpiece, carry bag, and user manual; Model 7070-1 - Consisting of the Aeroneb Go, battery controller, battery controller cable, 3 AA alkaline batteries, AC wall adapter, European mask elbow, mouthpiece, carry bag, and user manual. 7000LINCARE - Consisting of the Aeroneb Go, battery controller with a Lincare private label cover plate, battery controller cable, 3 AA alkaline batteries, mask elbow, mouthpiece, carry bag, and user manual; 7070LINCARE - Consisting of the Aeroneb Go, battery controller with the Lincare private label cover plate, battery controller cable, 3 AA alkaline batteries, AC wall adapter, mask elbow, mouthpiece, carry bag, and user manual.
FDA Recall
Terminated
·Medical Industries America Inc·Product code CAF·September 7, 2004
Medtronic, DBS Extension Kit for Deep Brain Stimulation, Catalog # 7482, 37085, 37086. Rx Only, Manufactured in: Medtronic, Inc. Villalba, Puerto Rico. Medtronic DBSTM Therapy for Parkinson's Disease - Bilateral stimulation of the internal globus pallidus (GPi) or the subthalamic nucleus (STN) using Medtronic DBS Therapy for Parkinson's Disease is indicated for adjunctive therapy in reducing some of the symptoms of advanced, levodopa-responsive Parkinson's disease that are not adequately controlled with medication. STN/GPi target system components: Kinetra Model 7428 or Soletra Model 7426 Neurostimulator Activa PC Model 37601, Activa RC Model 37612, Activa SC Model 37602, or Activa SC Model 37603 Neurostimulator Model 7482, Model 7482A, Model 7483, Model 37085, or Model 37086 Extension Model 3387 or Model 3389 Lead Medtronic DBS Therapy for Tremor - Unilateral thalamic stimulation of the ventral intermediate nucleus (VIM) using Medtronic DBS Therapy for Tremor is indicated for the suppression of tremor in the upper extremity. The system is intended for patients who are diagnosed with essential tremor or parkinsonian tremor not adequately controlled by medications and where the tremor constitutes a significant functional disability. VIM target system components: Soletra Model 7426 Neurostimulator Activa PC Model 37601, Activa RC Model 37612, Activa SC Model 37602, or Activa SC Model 37603 Neurostimulator Model 7482, Model 7482A, Model 7483, Model 37085, or Model 37086 Extension Model 3387 or Model 3389 Lead.
FDA Recall
Terminated
·Medtronic Neuromodulation·Product code MHY·December 3, 2012