1. Power Port isp M.R.I. Implantable Port with Attachable 9.6 F Open-Ended Single-Lumen Venous Catheter with Suture Plugs, Ref: 1809660, UDI: (01)00801741027154 2. PowerPort isp M.R.I. Implantable Port With Attachable 9.6 F Open-Ended Single-Lumen Venous Catheter Without Suture Plugs, Ref: 1809661, UDI: (01)00801741027161 3. PowerPort isp M.R.I. Implantable Port with Pre-Attached 9.6F Open-Ended Single-Lumen Venous Catheter with Suture Plugs, Ref: 1859660, UDI: (01)00801741027222 4. PowerPort isp M.R.I. Implantable Port with Pre-Attached 9.6 F Open-Ended Single-Lumen Venous Catheter without Suture Plugs, Ref: 1859661, UDI: (01)00801741027239 Product Usage: Bard implantable ports are indicated for patient therapies requiring repeated access to the vascular system. The port system can be used for infusion of medications, I.V. fluids, parenteral nutrition solutions, blood products, and for the withdrawal of blood samples.
FDA Recall
Terminated
·Bard Peripheral Vascular Inc·Product code LJT·October 1, 2019
Cushion, Pad, Denture, Wax Impregnated Cotton, Over The Counter
FDA classification
FDA Class 1
·Cushion, Pad, Denture, Wax Impregnated Cotton, Over The Counter
Brand Name: Da Vinci 5 Product Name: ASSY,DV5 TOWER,IS5000 Model/Catalog Number: 380746 Software Version: N/A Product Description: Preface: This report under 21 CFR 806.10 is being submitted for the dV5 system tower, as the NIR Handheld Camera or SOCK is developed and integrated as part of the dV5 system. The affected component of the dV5 system tower is the NIR handheld camera, and is supplied by Schoelly as the manufacturer. Therefore, the product description in this report references the NIR handheld camera system. Product Description: The NIR handheld camera system is compatible for use with the da Vinci 5 system to aid in surgery. The components of the NIR handheld camera system include a camera control unit and a light source, NIR handheld camera, and additional components that together, connect to the Tower of the da Vinci 5 system. When setting up the da Vinci 5 system, the image from the NIR handheld camera system is displayed on the Tower monitor. Component: Yes, the SOCK is the component and integrated into the dV5 system
FDA Recall
Open, Classified
·Intuitive Surgical, Inc.·Product code NAY·April 24, 2026
da Vinci S/Si EndoWrist 8mm Monopolar Curved Scissors Model No. 420179-16 Product Usage: EndoWrist Instruments, including scissors, scalpels, forceps, needle drivers and electrocautery are intended for endoscopic manipulation of tissue, including: grasping, cutting, blunt and sharp dissection, approximation, ligation, electrocautery and suturing. The Intuitive Surgical Endoscopic Instrument Control System is intended to assist in the accurate control of Intuitive Surgical Endoscopic Instruments including rigid endoscopes, blunt and sharp endoscopic dissectors, scissors, scalpels, ultrasonic shears, forceps/pick-ups, needle holders, endoscopic retractors, stabilizers, electrocautery and accessories for endoscopic manipulation of tissue, including grasping, cutting, blunt and sharp dissection, approximation, ligation, electrocautery, suturing, and delivery and placement of microwave and cryogenic ablation probes and accessories, during urologic surgical procedures, general laparoscopic surgical procedures, gynecologic laparoscopic surgical procedures, transoral otolaryngology surgical procedures restricted to benign and malignant tumors classified as TI and T2, and for benign base of tongue resection procedures, general thoracoscopic surgical procedures, and thoracoscopically assisted cardiotomy procedures. The system can also be employed with adjunctive mediastinotomy to perform coronary anastomosis during cardiac revascularization. The system is indicated for adult and pediatric use (except for transoral otolaryngology surgical procedures). It is intended to be used by trained physicians in an operating room environment in accordance with the representative, specific procedures set forth in the Professional Instructions for Use.
FDA Recall
Open, Classified
·Intuitive Surgical, Inc.·Product code NAY·August 15, 2018
da Vinci X/Xi EndoWrist 8mm Monopolar Curved Scissors Model No. 470179-14 Product Usage: EndoWrist Instruments, including scissors, scalpels, forceps, needle drivers and electrocautery are intended for endoscopic manipulation of tissue, including: grasping, cutting, blunt and sharp dissection, approximation, ligation, electrocautery and suturing. The Intuitive Surgical Endoscopic Instrument Control System is intended to assist in the accurate control of Intuitive Surgical Endoscopic Instruments including rigid endoscopes, blunt and sharp endoscopic dissectors, scissors, scalpels, ultrasonic shears, forceps/pick-ups, needle holders, endoscopic retractors, stabilizers, electrocautery and accessories for endoscopic manipulation of tissue, including grasping, cutting, blunt and sharp dissection, approximation, ligation, electrocautery, suturing, and delivery and placement of microwave and cryogenic ablation probes and accessories, during urologic surgical procedures, general laparoscopic surgical procedures, gynecologic laparoscopic surgical procedures, transoral otolaryngology surgical procedures restricted to benign and malignant tumors classified as TI and T2, and for benign base of tongue resection procedures, general thoracoscopic surgical procedures, and thoracoscopically assisted cardiotomy procedures. The system can also be employed with adjunctive mediastinotomy to perform coronary anastomosis during cardiac revascularization. The system is indicated for adult and pediatric use (except for transoral otolaryngology surgical procedures). It is intended to be used by trained physicians in an operating room environment in accordance with the representative, specific procedures set forth in the Professional Instructions for Use.
FDA Recall
Open, Classified
·Intuitive Surgical, Inc.·Product code NAY·August 15, 2018
Brand Name: Da Vinci X and Da Vinci Xi Product Name: da Vinci X, Xi Surgical System Model/Catalog Number: IS4000; IS4200 Software Version: N/A Product Description: he da Vinci Xi, X Surgical systems each consist of three main components: the Surgeon Console (SC), the Vision Cart (VC), and the Patient Cart (PC). The PC is the operative component of the system, and its primary function is to support the instrument arms and camera arm. Each system have four Universal Surgical Manipulators (USMs) also known as arms, which allow the surgeon to control up to three instruments and an endoscope simultaneously to perform surgical tasks (e.g. cutting, suturing, tissue approximation) in a variety of procedures. As the surgeon moves the hand controls within the console, the PC moves the robotic instruments within the patient in a corresponding manner. The da Vinci system and its software are designed such that instruments motion precisely tracks the motion inputs from the hand controls during surgery. Component: The affected part based on this recall, 380647-xx, USM, is a sub component of da Vinci Surgical Instrument
FDA Recall
Open, Classified
·Intuitive Surgical, Inc.·Product code NAY·April 2, 2026
Brand Name: Ion Endoluminal System Product Name: Ion Vision Probe Bag Model/Catalog Number: 490127 Software Version: N/A Product Description: The Ion Endoluminal System is a robotically assisted platform for minimally invasive peripheral lung biopsy. Ion consists of a System Cart and Controller that are used to navigate a flexible Catheter within the pulmonary tract using endoscopic visualization for diagnostic and therapeutic procedures. The Ion Fully Articulating Catheter (referred to as the Catheter) consists of the housing, sensor, input discs, shaft, tool channel, and tip. The Catheter is installed on the carriage of the arm. The Catheter is provided non-sterile and is a multi-use device. The Ion Peripheral Vision Probe (referred to as the Vision Probe or VP) is an endoscope that is compatible with, and inserted into, the Catheter tool channel. The VP provides direct visualization of the patient s airways during navigation. The VP attaches to the arm and has a collar that is rotated and then pulled to release it from the arm. The VP is provided non-sterile and is a multi-use device that can be used up to 5 times. The Vision Probe Bag (referred to as VPB) installs over the Instrument Arm for temporary storage of the VP when it is not inserted within the Catheter tool channel. The VPB is a single-use device provided sterile (folded within a pouch) by Ethylene Oxide (EO) sterilization method. Refer to HHE for additional details. Component: N/A
FDA Recall
Open, Classified
·Intuitive Surgical, Inc.·Product code EOQ·December 4, 2025
ORTHOPEDIC SURGICAL PACK HOSPITAL SAN CRISTOBAL CONTENTS: (I) CAUTERY TIP POLISH ER LIF (1) BAG SUTURE FLORAL (1) TUBE SUCTION CONNECT W' X 1 2' LIF (1) BAG GLASSINE (2) LITE GLOVE (1) TABLE COVER BTC 77" X 11 0" HD FULL COVERAGE LIF (1) MAYO STAND COVER REINFORCED LIF (5) TOWELS ABSORBENT 1 5" X 20" LIF (4) DRAPE UTILITY WITH TAPE LIF ( 1 ) DRAPE SHEET 70" X 100" L/ F (5) LAP SPONGE PREWASH 18" X 1 8" XRD LIF (1 ) MAYOTRAYLARGE (1) DRAPE TOP WITH ADHESIVE 108" X 50" STD SMS LIF (1) SKIN STAPLER WIDE 35 LIF ( 1) DRAPE INCISE ANTI M I CROBIAL 23" X 1 7" LIF (1) SKIN MARKER WITH RULER (1) U-DRAPE 60" X 70" WITH TAPE SPLIT 6" X 2 1 " LIF (1 ) PAD ABDOM INAL 8" X 7"h.'' (1) YAUNKAUER SUCTION TUBE WITHOUT VENT LIF (1) SOLUTI ON SURG ICAL DURAPREP 26ML LIF (1 ) BLADE SURG ICAL #10 STAINLESS STEEL (I) SPLIT SHEET WITH ADHESIVE 108" X 77" STD SMS LIF (2) *Prs. GLOVE # 8.5 SURGEON NEUTRALON LATEX ( I ) *Pr. GLOVE# 8 SURGEON NEUTRALON LATEX ( I ) GOWN SURG. REINFORCED XL TOWEL/WRAP AAMI Ill (3) GOWN XL SMS IM PERVIOUS REINFORCED AAM I III LIF ( I ) CAUTERY PENCIL ROCK ER SWITCH (2) *Prs. GLOVES SURG. # 8 POWDER (4) Prs. GLOVES SURG. 8.5 Product Usage: EO sterilized surgical convenient packs packaged into polyester/polyethylene breather bag with Tyvek double vents.
FDA Recall
Terminated
·Customed, Inc Calle Igualdad Final # 7·Product code OJH·May 20, 2014
System, Optical Impression, Computer Assisted Design And Manufacturing (Cad/Cam) Of Dental Restorations
FDA classification
FDA Class 2
·System, Optical Impression, Computer Assisted Design And Manufacturing (Cad/Cam) Of Dental Restorations
Therapeutic Vibrational Mattress Pad, Adjunct Use In Neonatal Abstinence Syndrome Or Neonatal Opioid Withdrawal Syndrome
FDA classification
FDA Class 2
·Therapeutic Vibrational Mattress Pad, Adjunct Use In Neonatal Abstinence Syndrome Or Neonatal Opioid Withdrawal Syndrome
Pad, Menstrual, Scented, Scented-Deodorized Made Of Common Cellulosic & Synthetic Material W/Established Safety Profile
FDA classification
FDA Class 1
·Pad, Menstrual, Scented, Scented-Deodorized Made Of Common Cellulosic & Synthetic Material W/Established Safety Profile