FDA UDI
In Commercial Distribution
🇺🇸 United States
SG 066-2N 1 liter latex-free reservoir bag
DI: M996SG0662N0
·
Model: SG 066-2N
·
INSTRUMENTATION INDUSTRIES, INCORPORATED
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- SG 066-2N 1 liter latex-free reservoir bag
- Primary DI
- M996SG0662N0
- Version / Model
- SG 066-2N
- Company Name
- INSTRUMENTATION INDUSTRIES, INCORPORATED
- Labeler DUNS
- 053146767
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2015-10-24
- Public Version
- 2
- Public Version Date
- 2018-03-29
- Public Version Status
- Update
- Public Device Record Key
- 4ce410a3-4f81-4c87-ad13-c27370d47fa7
Device Description
The SG 066-2N 1 liter latex-free reservoir bag is intended to be used with the SG 066 Oxygen Enrichment Kit, while in use on certain ventilators to provide higher concentrations of oxygen to the patient by mixing room air with an oxygen source at the proximal airway.
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| BTC | Bag, Reservoir | Anesthesiology | 868.5320 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 34877 | Breathing circuit bag, single-use | A non-sterile elastomeric reservoir sac intended to store breathing gas during the respiratory cycle. The breathing bag may be on the inspiratory or expiratory limb of a breathing circuit depending on the breathing circuit design. It may also function as a maximum pressure limiting device during spontaneous or manually assisted ventilation. It may be made of conductive or non-conductive material and is typically used in anaesthesia or ventilator breathing circuits. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | M996SG0662N4 | HIBCC | Ziplock Bag | 25 | In Commercial Distribution | |
| Primary | M996SG0662N0 | HIBCC |
Customer Contacts
- Phone
- 412-854-1133
- [email protected]