FDA UDI
In Commercial Distribution
🇺🇸 United States
BE 30-115-B Exhalation Valve
DI: M996BE30115B0
·
Model: BE 30-115-B
·
INSTRUMENTATION INDUSTRIES, INCORPORATED
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- BE 30-115-B Exhalation Valve
- Primary DI
- M996BE30115B0
- Version / Model
- BE 30-115-B
- Company Name
- INSTRUMENTATION INDUSTRIES, INCORPORATED
- Labeler DUNS
- 053146767
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2017-02-11
- Public Version
- 3
- Public Version Date
- 2018-07-06
- Public Version Status
- Update
- Public Device Record Key
- 1286d0a7-098d-4f45-b360-04d394d41992
Device Description
This reusable exhalation valve is designed for use with ventilators. The exhalation valve prevents the inspired gases from escaping through the passage that will be made available to expired gases via an inflatable balloon. Also, the re-breathing of the expired gases are prevented by the balloon action.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- ["High-level Disinfectant", "Ethylene Oxide", "Radiation Sterilization", "Moist Heat or Steam Sterilization"]
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| CBP | Valve, Non-Rebreathing | Anesthesiology | 868.5870 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 35425 | Non-rebreathing valve, reusable | A non-sterile device that is a one-way valve used to direct the flow of breathing gases and prevent the patient rebreathing the exhaled gases. It is typically used in a breathing system or between an oxygen mask and its reservoir bag. The device may be of various designs and will typically include unidirectional valves made of, e.g., silicone, rubber, metal, mica, sheets or discs that open and close for each inspiration/expiration. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | M996BE30115B0 | HIBCC |
Customer Contacts
- Phone
- 1-412-854-1133
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K980725 | 000 |