FDA UDI
In Commercial Distribution
🇺🇸 United States
BE 117 Non-Rebreathing Tee Valve
DI: M996BE1170
·
Model: BE 117
·
INSTRUMENTATION INDUSTRIES, INCORPORATED
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- BE 117 Non-Rebreathing Tee Valve
- Primary DI
- M996BE1170
- Version / Model
- BE 117
- Company Name
- INSTRUMENTATION INDUSTRIES, INCORPORATED
- Labeler DUNS
- 053146767
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2015-10-24
- Public Version
- 3
- Public Version Date
- 2018-07-06
- Public Version Status
- Update
- Public Device Record Key
- 30aa1d2c-37b1-4610-b64e-4bdf30a87390
Device Description
The reusable BE 117 Non-Rebreathing ‘T’ is designed for use with a spontaneously breathing patient where “back flow” must be avoided. The ‘T’ is designed to prevent the flow of gas back toward the source and to ensure unilateral breathing.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- ["Radiation Sterilization", "Ethylene Oxide", "High-level Disinfectant"]
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| CBP | Valve, Non-Rebreathing | Anesthesiology | 868.5870 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 35425 | Non-rebreathing valve, reusable | A non-sterile device that is a one-way valve used to direct the flow of breathing gases and prevent the patient rebreathing the exhaled gases. It is typically used in a breathing system or between an oxygen mask and its reservoir bag. The device may be of various designs and will typically include unidirectional valves made of, e.g., silicone, rubber, metal, mica, sheets or discs that open and close for each inspiration/expiration. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | M996BE1172 | HIBCC | ziplock bag | 10 | In Commercial Distribution | |
| Primary | M996BE1170 | HIBCC |
Customer Contacts
- Phone
- 412-854-1133
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K973066 | 000 |