TwinFlo™ Catheter
Basic Information
- Brand Name
- TwinFlo™ Catheter
- Primary DI
- M781DFH80115901
- Version / Model
- DFH80-115/90
- Company Name
- Thermopeutix, Inc.
- Labeler DUNS
- 138648154
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-09-19
- Public Version
- 4
- Public Version Date
- 2023-12-04
- Public Version Status
- Update
- Public Device Record Key
- 64cab480-9eb0-4cf1-ad31-a9bdc181d993
Device Description
The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating.
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| MJN | Catheter, Intravascular Occluding, Temporary | Cardiovascular | 870.4450 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 32584 | Intravascular occluding balloon catheter, image-guided | A non-powered flexible tube with an inflatable balloon(s) at the distal end intended to be introduced short-term under image guidance to temporarily block a blood vessel. It may be used for arteriography, selective angiography, preoperative occlusion, peripheral and intracranial vasculature occlusion, emergency control of haemorrhage, to treat aneurysms, chemotherapeutic drug infusion, and renal opacification procedures. It may have a dual- or multi-lumen design for balloon inflation, introduction over a guidewire, infusion of contrast medium, or delivery of a smaller catheter or embolic agents; some types have graduated markings to assist insertion. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | M781DFH80115901 | HIBCC |
Customer Contacts
- Phone
- 1-858-549-1760
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | Outflow Length: 90 cm | ||
| Device Size Text, specify | Inflow Length: 115 cm | ||
| Device Size Text, specify | Balloon Diameter: 8.0 mm | ||
| Device Size Text, specify | Sheath Compatibility: 14 Fr |
Storage Conditions
- Type
- Handling Environment Temperature
- Temperature Range
- -29 – 55 Degrees Celsius