FDA UDI In Commercial Distribution 🇺🇸 United States

TwinFlo™ Catheter

DI: M781DFH10115801 · Model: DFH10-115/80 · Thermopeutix, Inc.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1

Basic Information

Brand Name
TwinFlo™ Catheter
Primary DI
M781DFH10115801
Version / Model
DFH10-115/80
Company Name
Thermopeutix, Inc.
Labeler DUNS
138648154
Distribution Status
In Commercial Distribution
Device Count in Pkg
1
Record Status
Published
Publish Date
2016-09-19
Public Version
4
Public Version Date
2023-12-04
Public Version Status
Update
Public Device Record Key
94f734bc-76c4-4ed1-925e-e9e1c000ca48

Device Description

The TwinFlo™ Catheter consists of a two concentric tubular shafts (inflow and outflow lumens, IFL and OFL) that can infuse diagnostic and therapeutic agents to selected regions, as well as direct arterial blood or other solutions to a specific region or organ. The lumens may be accessed using external devices connected to these lumens. There are two additional smaller lumens; one lumen is used for inflation of the distal balloon on the inflow lumen while the second small lumen permits pressure monitoring distal to the balloon. Inflation of the balloon isolates the region distal to the balloon permitting infusion into the vascular region of interest. When used to provide perfusion or control blood flow, blood exits via the outflow lumen to an extracorporeal circuit and is returned via the inflow lumen distal to the inflated balloon. The catheter is supplied with heparin in the hydrophilic coating.

Device Characteristics

Single Use
Yes
Prescription Use (Rx)
Yes
Over the Counter (OTC)
No
Kit
No
Combination Product
No
HCT/P
No
Contains NRL
No
Not Made with NRL
No
MRI Safety
Labeling does not contain MRI Safety Information
Direct Marking Exempt
No
PM Exempt
No
Has Serial Number
No
Has Lot/Batch Number
Yes
Has Manufacturing Date
Yes
Has Expiration Date
Yes
Has Donation ID
No

Sterilization

Is Sterile
Yes
Sterilization Prior Use
No

Product Codes

Code Name
MJN Catheter, Intravascular Occluding, Temporary

GMDN Terms

Code Name
32584 Intravascular occluding balloon catheter, image-guided

Identifiers

Type ID
Primary M781DFH10115801

Customer Contacts

Device Sizes

Type Value Unit Text
Device Size Text, specify Outflow Length: 80 cm
Device Size Text, specify Inflow Length: 115 cm
Device Size Text, specify Balloon Diameter: 10.0 mm
Device Size Text, specify Sheath Compatibility: 14 Fr

Storage Conditions

Type
Handling Environment Temperature
Temperature Range
-29 – 55 Degrees Celsius