FDA UDI
In Commercial Distribution
🇺🇸 United States
CAPTURE
DI: M7404205320
·
Model: 70-01-001-0
·
SPINEOLOGY INC.
Product Codes
4
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- CAPTURE
- Primary DI
- M7404205320
- Version / Model
- 70-01-001-0
- Catalog Number
- 420-5320
- Company Name
- SPINEOLOGY INC.
- Labeler DUNS
- 033014361
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2015-10-05
- Public Version
- 4
- Public Version Date
- 2024-09-11
- Public Version Status
- Update
- Public Device Record Key
- 8de6e1e2-8b30-439d-8fe4-25b84a5ac09c
Device Description
Capture Facet Screw
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Unsafe
- Direct Marking Exempt
- Yes
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| MRW | System, Facet Screw Spinal Device | Unknown | U | |
| MNI | ORTHOSIS, SPINAL PEDICLE FIXATION | Orthopedic | 888.3070 | 2 |
| NKB | Orthosis, spinal pedicle fixation, for degenerative disc disease | Orthopedic | 888.3070 | 2 |
| MNH | Orthosis, spondylolisthesis spinal fixation | Orthopedic | 888.3070 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 46651 | Spinal bone screw, non-bioabsorbable | A small, threaded, implantable rod with a screw head and drive intended for internal spinal fixation by being screwed into the spine to hold a correction/stabilization device (e.g., rod, plate, tether) to bone; it is made of a material that is not chemically degraded or absorbed via natural body processes (e.g., surgical steel, titanium alloy, carbon fibre). It is available in various types (e.g., pedicle or transfacet, with a slotted, cross, star, or polygonal drive), and is typically used to provide immobilization and stabilization of spinal segments in the treatment of spinal instabilities or deformities. A screw head adaptor intended to stabilize a rod may be included with the screw. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | M7404205320 | HIBCC |
Customer Contacts
- Phone
- +1(612)256-8500 ext. 534
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Length | 20 | Millimeter | |
| Device Size Text, specify | 5.25x20 |