FDA UDI
In Commercial Distribution
🇺🇸 United States
samaritan PAD
DI: M727SAM450P
·
Model: SAM 450P
·
HEARTSINE TECHNOLOGIES LTD
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- samaritan PAD
- Primary DI
- M727SAM450P
- Version / Model
- SAM 450P
- Company Name
- HEARTSINE TECHNOLOGIES LTD
- Labeler DUNS
- 230479318
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2017-02-13
- Public Version
- 2
- Public Version Date
- 2018-03-29
- Public Version Status
- Update
- Public Device Record Key
- 3466cc0a-1877-43c4-b2a4-89ca110ad726
Device Description
Semi-Automatic External Defibrillator
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| MKJ | Automated External Defibrillators (Non-Wearable) | Cardiovascular | 870.5310 | 3 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 47910 | Non-rechargeable public semi-automated external defibrillator | A portable electronic device designed to automatically detect cardiac arrhythmias (ventricular fibrillation/pulseless ventricular tachycardia) in a sudden cardiac arrest (SCA) patient, after which it audibly/visually instructs an operator to enable it to activate defibrillation of the heart through application of electrical shocks to the chest surface. It is placed in conspicuous public locations and is intended to be operated by a layperson. It consists of two skin-adhesive, cartridge-type, disposable electrodes containing non-rechargeable batteries that provide the shock energy, and an electrode-regulating external pulse generator (EPG), which may include a CPR feedback. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | M727SAM450P | HIBCC |
Customer Contacts
- Phone
- 1-866-478-7463
- [email protected]
Storage Conditions
- Type
- Special Storage Condition, Specify
- Special Conditions
- Minus 10 to 50 degrees Celsius for up to two days. It should be returned to an ambient temperature of between 0 to 50 degrees Celsius for at least 24 hours before use.
- Type
- Storage Environment Humidity
- Temperature Range
- 5 – 95 Percent (%) Relative Humidity
- Type
- Storage Environment Temperature
- Temperature Range
- 0 – 50 Degrees Celsius