Ovation Prime Abdominal Stent Graft System
Basic Information
- Brand Name
- Ovation Prime Abdominal Stent Graft System
- Primary DI
- M701TVCS14G1
- Version / Model
- CustomSeal Kit
- Catalog Number
- TV-CS14-G
- Company Name
- ENDOLOGIX, INC.
- Labeler DUNS
- 858560477
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2014-10-07
- Public Version
- 8
- Public Version Date
- 2023-01-10
- Public Version Status
- Update
- Public Device Record Key
- dcca5dfb-8a7c-4019-adbc-3e4ac5dcc1a1
Device Description
The TriVascular® Ovation Prime® Abdominal Stent Graft System is an endovascular device delivered via a small diameter catheter to treat abdominal aortic aneurysms (AAAs). The stent graft is designed to reline the diseased vasculature, providing an endovascular blood conduit for isolating the aneurysm from the high pressure flow of blood, thereby reducing the risk of rupture. The stent graft is a modular configuration comprised of an aortic body section, iliac limbs, and iliac extensions as required. The TriVascular Ovation Prime Abdominal Stent Graft System includes, an Aortic Body Stent Graft and delivery catheter, Iliac Limb Stent Grafts and delivery catheters, Iliac Extension Stent Grafts and delivery catheters, as required, a Fill Kit, and an Autoinjector.
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Conditional
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| MIH | System, Endovascular Graft, Aortic Aneurysm Treatment | Unknown | 3 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 46777 | Abdominal aorta endovascular stent-graft | A non-bioabsorbable tubular device typically implanted at the junction of the abdominal aorta and the common iliac arteries to reduce pressure on an abdominal aortic aneurysm (AAA); it does not contain anticoagulants or pharmaceuticals that prevent narrowing of the vessels. It is percutaneously inserted via the femoral artery to the site of implantation where it self-expands. It is typically made of a metallic outer mesh structure with an inner polymer tube (endovascular graft) and is typically available in two designs: 1) a single tube for insertion into one iliac artery; or 2) a two-part bifurcation design (e.g., Y-shaped tube) for insertion through both iliac arteries. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | M701TVCS14G1 | HIBCC |
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| P120006 | 008 |
| P120006 | 009 |
| P120006 | 010 |
| P120006 | 017 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Total Volume | 14 | Milliliter |
Storage Conditions
- Type
- Special Storage Condition, Specify
- Special Conditions
- Store in a cool, dry place.