FDA UDI
In Commercial Distribution
🇺🇸 United States
Perfecta
DI: M684378018001
·
Model: 37801800
·
Microport Orthopedics Inc.
Product Codes
2
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- Perfecta
- Primary DI
- M684378018001
- Version / Model
- 37801800
- Catalog Number
- 37801800
- Company Name
- Microport Orthopedics Inc.
- Labeler DUNS
- 079118736
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2015-10-20
- Public Version
- 2
- Public Version Date
- 2018-03-29
- Public Version Status
- Update
- Public Device Record Key
- a92bcc91-ce3a-4361-8662-89ece6f789bf
Device Description
PERFECTA® PDA TITANIUM FEMORAL STEM SZ 18.0 STD FLR COLLARED
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| JDI | Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented | Orthopedic | 888.3350 | 2 |
| LPH | Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented | Orthopedic | 888.3358 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 34203 | Uncoated femoral stem prosthesis, modular | A sterile implantable device designed to replace the proximal femoral neck as part of a total hip arthroplasty (THA). The device is composed of two or more separate segments designed to be joined, is made of metal [e.g., cobalt-chrome (Co-Cr), titanium (Ti), stainless steel], and is not coated with materials intended to improve fixation and stability by promoting bone ingrowth. Fixation devices for implantation (e.g., screws and bolts) may be included and implantation is intended to be performed with bone cement. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Direct Marking | 37801800 | HIBCC | ||||
| Primary | M684378018001 | HIBCC |
Customer Contacts
- Phone
- 1-866-872-0211
- [email protected]