FDA UDI
In Commercial Distribution
🇺🇸 United States
HyProCure II Sinus Tarsi Stent Size 07
DI: M621HYPII070
·
Model: HYP II-07
·
Gramedica
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- HyProCure II Sinus Tarsi Stent Size 07
- Primary DI
- M621HYPII070
- Version / Model
- HYP II-07
- Catalog Number
- HYP II-07
- Company Name
- Gramedica
- Labeler DUNS
- 828660345
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2017-04-04
- Public Version
- 5
- Public Version Date
- 2022-11-28
- Public Version Status
- Update
- Public Device Record Key
- 2a3b9fee-0745-4f44-bc52-d095c93aa436
Device Description
HyProCure II Sinus Tarsi Implant Size 07. Indications: HyProCure II (HYP II and HYP IIs) is an implant stabilization device used in the treatment of hyperpronating instability of the hindfoot. The implant is designed to stabilize the talus to prevent excessive anterior, and/or medial, and/or plantarflexion of the talus, while allowing normal talotarsal joint motion.
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HWC | Screw, Fixation, Bone | Orthopedic | 888.3040 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 40352 | Subtalar implant, non-bioabsorbable | A device designed to be implanted into the calcaneus bone or sinus tarsi of the foot to stabilize the subtalar/talotarsal joint to treat a hyperpronated foot (inward rotation during gait) and sequelae (e.g., flat foot) or other heel/arch abnormalities. It is a non-bioabsorbable device typically made of a metal (e.g., titanium alloy) or polyethylene (PE). | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | M621HYPII070 | HIBCC |
Customer Contacts
- Phone
- 586-677-9600
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K142534 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | 07mm |