FDA UDI
In Commercial Distribution
🇺🇸 United States
V-Loop Variable Loop Catheter Manipulator
DI: M58800100245210
·
Model: 1
·
STEREOTAXIS, INC.
Product Codes
2
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- V-Loop Variable Loop Catheter Manipulator
- Primary DI
- M58800100245210
- Version / Model
- 1
- Catalog Number
- 001-002452-1
- Company Name
- STEREOTAXIS, INC.
- Labeler DUNS
- 024942265
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-05-02
- Public Version
- 2
- Public Version Date
- 2018-03-29
- Public Version Status
- Update
- Public Device Record Key
- 96307819-3c70-4167-9672-03f5491171c0
Device Description
The Vdrive with V-Loop disposable is indicated to remotely control the advancement, retraction, rotation, tip deflection and loop size of compatibile loop catheters inserted across the septum into the left atrium using conventional procedures
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DXX | System, Catheter Control, Steerable | Cardiovascular | 870.1290 | 2 |
| DQX | Wire, Guide, Catheter | Cardiovascular | 870.1330 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 31742 | Cardiac mapping system workstation | A mains electricity (AC-powered) device designed as a control unit to percutaneously navigate (orientate and steer) a cardiac mapping system catheter, or its associated guidewire, in the desired direction to the designated target site (e.g., coronary vasculature). It uses dedicated software and may employ various technologies (often magnetic fields); it is typically used in the electrophysiology (EP) laboratory. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | M58800100245210 | HIBCC |
Customer Contacts
- Phone
- 13146786100
- [email protected]
Storage Conditions
- Type
- Special Storage Condition, Specify
- Special Conditions
- Keep Dry
- Type
- Special Storage Condition, Specify
- Special Conditions
- Keep Away from Sunlight