FDA UDI
In Commercial Distribution
🇺🇸 United States
Fixate™ Suturing Device
DI: M365FB101010
·
Model: SC-4317-01
·
BOSTON SCIENTIFIC NEUROMODULATION CORPORATION
Product Codes
2
GMDN Terms
2
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Fixate™ Suturing Device
- Primary DI
- M365FB101010
- Version / Model
- SC-4317-01
- Catalog Number
- SC-4317-01
- Company Name
- BOSTON SCIENTIFIC NEUROMODULATION CORPORATION
- Labeler DUNS
- 824951958
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2014-09-24
- Public Version
- 5
- Public Version Date
- 2023-06-02
- Public Version Status
- Update
- Public Device Record Key
- d2e600b2-8a6e-498c-bd3c-a2d4ce7d6fc9
Device Description
Fixate™ Suturing Device
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Ethylene Oxide
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GAT | SUTURE, NONABSORBABLE, SYNTHETIC, POLYETHYLENE | General, Plastic Surgery | 878.5000 | 2 |
| GZB | STIMULATOR, SPINAL-CORD, IMPLANTED (PAIN RELIEF) | Neurology | 882.5880 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 13907 | Polyolefin/fluoropolymer suture, multifilament | A multiple-strand (multifilament), synthetic, non-bioabsorbable thread made of a polyolefin (e.g., polypropylene, polyethylene) or fluoropolymer (e.g., polytetrafluoroethylene, polyvinylidene fluoride) intended to join (i.e., approximate) the edges of a soft-tissue wound or incision by stitching or to ligate soft tissues; it may include an attached disposable device(s) [e.g., needle, passer] intended to facilitate suture application. The thread provides temporary wound support until the wound sufficiently heals to withstand normal stress. It is not a barbed suture and does not include antimicrobial agents/materials. This is a single-use device. | Yes | Active |
| 36007 | Analgesic spinal cord electrical stimulation system | An assembly of devices that applies an electrical stimulus to all or part of the spinal cord to relieve pain (analgesia). It includes an implanted lead/electrode system located in the epidural space of the spinal cord attached to either an implanted passive electronic circuit into which signals and/or energy is inductively coupled from outside the body, or to a totally implantable self-contained system that carries its own energy source and has no inherent dependence upon external devices. It is used to treat acute and/or chronic intractable pain, where the use of drug therapy is undesirable or no longer effective. | No | Obsolete |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | M365FB101010 | HIBCC |