FDA UDI
Not in Commercial Distribution
🇺🇸 United States
1.5 mm Inion CPS®
DI: M224PLT10309
·
Model: 1
·
Inion Oy
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- 1.5 mm Inion CPS®
- Primary DI
- M224PLT10309
- Version / Model
- 1
- Catalog Number
- PLT-1030
- Company Name
- Inion Oy
- Labeler DUNS
- 367994657
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2017-02-07
- Public Version
- 8
- Public Version Date
- 2026-01-01
- Public Version Status
- Update
- Public Device Record Key
- 4d815494-4ae4-435a-abb9-9e23a0abaeaa
- Distribution End Date
- 2026-01-01
Device Description
Mesh plate, 7x7 holes
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- Yes
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| JEY | PLATE, BONE | Dental | 872.4760 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 44688 | Extra-gynaecological surgical mesh, synthetic polymer, bioabsorbable | An implantable material (e.g., flat sheet) made from a bioabsorbable synthetic polymer(s) [e.g., polyglycolic acid (PGA), polyglycolide] intended for extra-gynaecological, non-dental tissue repair/reinforcement application(s) [e.g., pericardial reinforcement, plastic surgery, abdominal hernia repair]. It may also be intended as a short-term scaffold for tissue regeneration. Disposable devices associated with implantation may be supplied with the mesh. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | M224PLT10309 | HIBCC |
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K010352 | 000 |