FDA UDI
Not in Commercial Distribution
🇺🇸 United States
Guardian® II NC hemostasis valve
DI: M20682150
·
Model: 8215
·
Vascular Solutions, Inc.
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- Guardian® II NC hemostasis valve
- Primary DI
- M20682150
- Version / Model
- 8215
- Company Name
- Vascular Solutions, Inc.
- Labeler DUNS
- 008999906
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-09-06
- Public Version
- 6
- Public Version Date
- 2023-06-09
- Public Version Status
- Update
- Public Device Record Key
- 2b46ddbf-5fc2-47c5-8775-a1ab59959fa4
- Distribution End Date
- 2021-11-21
Device Description
The Guardian hemostasis valves are intended to maintain hemostasis during the use of diagnostic or interventional devices. Guardian hemostasis valves are indicated for maintaining a seal around diagnostic/interventional devices with outside diameters up to 8F (0.105" or 2.67mm) during diagnostic/interventional procedures.
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DTL | Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass | Cardiovascular | 870.4290 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 36079 | Haemostasis valve | A noninvasive device designed as a conduit through which a small-diameter diagnostic/interventional device(s) can be introduced into or withdrawn from a patient's vasculature while preventing backflow of blood; it might in addition be intended for urinary applications. It is intended to be attached, typically via Luer-lock, to an invasively-placed catheter introducer (not included) and typically has a self-sealing lumen(s) [e.g., Touhy-Borst valve] and sideport for the introduction of solutions. It may include noninvasive guidewire accessories (e.g., guidewire introducer). It is not designed to be connected between tubing (i.e., not an in-line valve). This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | M20682150 | HIBCC | ||||
| Package | M20682151 | HIBCC | Box | 25 | Not in Commercial Distribution | 2021-11-21 |
Customer Contacts
- Phone
- 888-240-6001
- [email protected]