FDA UDI
In Commercial Distribution
🇺🇸 United States
DELTRAN
DI: H671DPT2000
·
Model: Standard Single Kit
·
UTAH MEDICAL PRODUCTS, INC.
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- DELTRAN
- Primary DI
- H671DPT2000
- Version / Model
- Standard Single Kit
- Catalog Number
- DPT-200
- Company Name
- UTAH MEDICAL PRODUCTS, INC.
- Labeler DUNS
- 094651270
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-09-23
- Public Version
- 4
- Public Version Date
- 2019-12-18
- Public Version Status
- Update
- Public Device Record Key
- c36a636a-65fd-4628-9dcb-24b932baf002
Device Description
Disposable Pressure Transducer System, 3cc/hr Flow Rate, with Vented Red Caps, Micro Drip Chamber
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DRS | Transducer, Blood-Pressure, Extravascular | Cardiovascular | 870.2850 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 45275 | Invasive blood pressure transducer set | A collection of devices that includes tubing, a pressure transducer(s), and other items [e.g., connectors, stopcock(s), clamps and filters] intended to be used for an invasive blood pressure measurement. This set will typically connect directly to the applied invasive catheter and the transducer will provide the electrical signals for display by a patient monitoring system. This device will have physical characteristics appropriate for preserving, to the extent possible, the waveform and fidelity of the measured pressure. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | H671DPT2001 | HIBCC | Box | 25 | In Commercial Distribution | |
| Primary | H671DPT2000 | HIBCC |
Customer Contacts
- Phone
- 800-533-4984
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | Flow Rate - 3 cc/hr |