FDA UDI
In Commercial Distribution
🇺🇸 United States
PEAK MEDICAL
DI: G45333240125BC0
·
Model: 3324-0125BC
·
Peak Medical Distribution Inc.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- PEAK MEDICAL
- Primary DI
- G45333240125BC0
- Version / Model
- 3324-0125BC
- Company Name
- Peak Medical Distribution Inc.
- Labeler DUNS
- 078393632
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2025-01-14
- Public Version
- 1
- Public Version Date
- 2025-01-22
- Public Version Status
- New
- Public Device Record Key
- 425b204c-e1ea-4c60-8a12-5501d306dd5e
Device Description
MANIFOLD DUAL TUBE HOLDER, 0.196" THICK, ANODISED CLEAR ALUMINIUM, 1.25 inch HIGH FOR TUBING SIZES. 0.5 inch, 0.375 inch, 0.375 inch, 0.25 inch, 0.25 inch, 0.25 inch, 0.0625 inch.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HXD | Clamp | General, Plastic Surgery | 878.4800 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 32146 | Medical tubing clip/clamp, temporary, non-calibrated, reusable | A non-sterile, manual device designed to compress a piece of medical device tubing or tubular container to reversibly occlude its lumen and stop the flow of material within; it is not intended for patient-contact. It has a manual mechanism (e.g., hinging, roller-type, vice-like) whereby pressure on the tube can be applied or removed, however it is not a calibrated device (e.g., it is often a roller type, clip, or screw-clamp). It may be referred to as a clip or a clamp. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | G45333240125BC0 | HIBCC |