FDA UDI In Commercial Distribution 🇺🇸 United States

Alleye

DI: EOMA32120 · Model: 3.2.12 · OCULOCARE medical AG
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1

Basic Information

Brand Name
Alleye
Primary DI
EOMA32120
Version / Model
3.2.12
Company Name
OCULOCARE medical AG
Labeler DUNS
480069957
Distribution Status
In Commercial Distribution
Device Count in Pkg
1
Record Status
Published
Publish Date
2023-05-15
Public Version
1
Public Version Date
2023-05-23
Public Version Status
New
Public Device Record Key
7dbc8846-8fc9-41ba-8eba-13121566b5c6

Device Description

Alleye® is a vision function test provided on a commercially available mobile phone. Alleye® implements an alignment hyperacuity task which helps patients with age-related macular degeneration (AMD) to assess their vision at home. This allows the timely detection of significant changes in vision function, enabling the regular monitoring of the disease progression and/or verifying the efficacy of ongoing treatments. Alleye is a digital technology, consisting of two different items: a mobile app for patients and a web interface for eye care professionals. Principle of Operation The test consists of 12 tasks that are performed on the user’s mobile phone. For each task, two dots are placed at each extremity of an invisible axis. A third dot is placed between these two dots, 40 pixels above or 40 pixels below the axis. The test consists in aligning the three dots by moving the dot in the middle. A single click on the up and down buttons moves the dot by 0.3 pixels up or down, respectively. If the patient maintains their finger on the buttons, the dot keeps moving. When it reaches a limit of 50 pixels away from its ideal position on the axis, the dot automatically stops. Once the user is satisfied with the position of the middle dot, they confirm it by tapping the circle button between the two arrow buttons. Overall, the patient must perform three alignments on four different axes (horizontal, vertical, oblique upper left / lower right, and oblique upper right / lower left). The test is performed on one eye only. The eye that is not being tested must be covered before starting the test. The TRAINING mode allows the patient to learn how to use the app, without recording the score results. To start the test, the patient must select TEST, and then select the eye (RIGHT or LEFT) to be tested. The Alleye tasks will proceed until COMMENT ON TEST appears on the screen. The patient can select REPEAT to start the test again, or DONE to save the test and display the results.

Device Characteristics

Single Use
No
Prescription Use (Rx)
Yes
Over the Counter (OTC)
No
Kit
No
Combination Product
No
HCT/P
No
Contains NRL
No
Not Made with NRL
No
MRI Safety
Labeling does not contain MRI Safety Information
Direct Marking Exempt
Yes
PM Exempt
No
Has Serial Number
No
Has Lot/Batch Number
Yes
Has Manufacturing Date
Yes
Has Expiration Date
No
Has Donation ID
No

Sterilization

Is Sterile
No
Sterilization Prior Use
No

Product Codes

Code Name
HOQ Grid, Amsler

GMDN Terms

Code Name
65889 Vision self-testing software

Identifiers

Type ID
Primary EOMA32120

Premarket Submissions

Submission Number Supplement Number
K180895 000