FDA UDI
In Commercial Distribution
🇺🇸 United States
DCP compression plate f. 3.5mm screws, length 74mm/6 holes
DI: EMAH00200700730
·
Model: 002-0070-073
·
mahe medical gmbh
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- DCP compression plate f. 3.5mm screws, length 74mm/6 holes
- Primary DI
- EMAH00200700730
- Version / Model
- 002-0070-073
- Catalog Number
- 002-0070-073
- Company Name
- mahe medical gmbh
- Labeler DUNS
- 342243334
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-08-01
- Public Version
- 3
- Public Version Date
- 2024-02-19
- Public Version Status
- Update
- Public Device Record Key
- 0a265e3f-76d5-4273-81b5-63bb3174a0f3
Device Description
DCP compression plate f. 3.5mm screws, length 74mm/6 holes
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HRS | Plate, fixation, bone | Orthopedic | 888.3030 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 61573 | Orthopaedic fixation plate, non-bioabsorbable, non-sterile | A non-sterile implantable sheet of firm material intended to be attached to fractured long bone fragments with screws to bridge and stabilize the fracture gap, and shield the site from stress as the bone heals; the material is not chemically degraded or absorbed by natural body processes (includes implant grade metal such as surgical steel, titanium alloy, or carbon fibre). The device is typically used to treat traumatic or pathological orthopaedic fractures; it may also be used to temporarily augment bone following a lengthening procedure, or for arthrodesis (joint fusion). This device is intended to be sterilized prior to use. | No | Obsolete |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | EMAH00200700731 | HIBCC | 1 | In Commercial Distribution | ||
| Primary | EMAH00200700730 | HIBCC |
Customer Contacts
- Phone
- +49(0)746592750
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Length | 73.94 | Millimeter | |
| Width | 10.21 | Millimeter | |
| Height | 3.4 | Millimeter |
Storage Conditions
- Type
- Special Storage Condition, Specify
- Special Conditions
- Cool, dark & dry place
- Type
- Handling Environment Humidity
- Temperature Range
- 10 – 50 Percent (%) Relative Humidity
- Type
- Storage Environment Temperature
- Temperature Range
- 10 – 28 Degrees Celsius