FDA UDI
In Commercial Distribution
🇺🇸 United States
FinePointer Cranial
DI: EFIAE012300CUS1
·
Model: 1
·
Fiagon GmbH
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- FinePointer Cranial
- Primary DI
- EFIAE012300CUS1
- Version / Model
- 1
- Company Name
- Fiagon GmbH
- Labeler DUNS
- 312623008
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-08-10
- Public Version
- 7
- Public Version Date
- 2023-09-18
- Public Version Status
- Update
- Public Device Record Key
- 15ec3b4b-9aec-4c9b-a35e-56f234743104
Device Description
The products FinePointer Cranial is a product variant of a navigated pointer probe for image guided surgical procedures The instruments are accessories to the Fiagon Navigation system. The Navigation system is indicated for any medical condition in which the use of stereotactic surgery may be appropriate, and where reference to a rigid anatomical structure in the field of cranial surgery can be identified relative to a CT or MR based model of the anatomy.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Unsafe
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HAW | Neurological Stereotaxic Instrument | Neurology | 882.4560 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 45199 | Multi-purpose stereotactic surgery system | An electrically-powered assembly of devices that typically consists of a rigid frame, positioning and alignment components, workstation, and a calibrated guide mechanism for precisely positioning probes, other instruments, or implantable devices during a surgical procedure of more than one discipline [e.g., orthopaedic and ear/nose/throat (ENT)]. The system may include computerized functions to store diagnostic images used for image-guided surgery. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | EFIAE012300CUS1 | HIBCC | ||||
| Direct Marking | EFIAE012300CUS0 | HIBCC |
Customer Contacts
- Phone
- +13364282241
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K151156 | 000 |
Storage Conditions
- Type
- Handling Environment Temperature
- Temperature Range
- 15 – 35 Degrees Celsius
- Type
- Handling Environment Humidity
- Temperature Range
- 30 – 75 Percent (%) Relative Humidity
- Type
- Storage Environment Atmospheric Pressure
- Temperature Range
- 70 – 106 KiloPascal