FDA UDI In Commercial Distribution 🇺🇸 United States

Piccolo Lipid Panel Plus

DI: EABA40000301 · Model: 400-0030 · ABAXIS, INC.
Product Codes
6
GMDN Terms
4
Identifiers
2
Pkg Device Count
10

Let the assistant research this device

The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.

Free to try · every answer cites its records

Basic Information

Brand Name
Piccolo Lipid Panel Plus
Primary DI
EABA40000301
Version / Model
400-0030
Catalog Number
400-0030
Company Name
ABAXIS, INC.
Labeler DUNS
555503770
Distribution Status
In Commercial Distribution
Device Count in Pkg
10
Record Status
Published
Publish Date
2016-09-23
Public Version
2
Public Version Date
2018-03-29
Public Version Status
Update
Public Device Record Key
c8f6bf8c-7451-4c6c-ab23-e7063c80f920

Device Description

The Piccolo® Lipid Panel Plus, used with the Piccolo® blood chemistry analyzer or the Piccolo Xpress® chemistry analyzer, is intended for the in vitro quantitative determination of total cholesterol (CHOL), high-density lipoprotein cholesterol (HDL), triglycerides (TRIG), alanine aminotransferase (ALT), aspartate aminotransferase (AST), and glucose (GLU) in capillary (fingerstick) lithium heparinized whole blood, venous lithium heparinized whole blood, lithium heparinized plasma, or serum in a clinical laboratory setting or point-of-care location. From the CHOL, HDL and TRIG determinations, low-density lipoprotein cholesterol (LDL), very low-density lipoprotein cholesterol (VLDL), non-HDL cholesterol, and a total cholesterol/high-density lipoprotein cholesterol ratio (TC/H) are calculated by the analyzer. Lipid measurements are used in the diagnosis and treatment of lipid and lipoprotein disorders, atherosclerosis, various liver and renal diseases, diabetes mellitus, and other diseases involving lipid metabolism or various endocrine disorders. The tests on this panel are waived under CLIA ’88 regulations. If a laboratory modifies the test system instructions, then the tests are considered high complexity and subject to all CLIA requirements. For CLIA waived labs, only lithium heparin whole blood (venous or capillary) may be tested. For use in moderate complexity labs, lithium heparinized whole blood, lithium heparinized plasma, or serum may be used.

Device Characteristics

Single Use
Yes
Prescription Use (Rx)
No
Over the Counter (OTC)
No
Kit
No
Combination Product
No
HCT/P
No
Contains NRL
No
Not Made with NRL
No
MRI Safety
Labeling does not contain MRI Safety Information
Direct Marking Exempt
No
PM Exempt
No
Has Serial Number
Yes
Has Lot/Batch Number
Yes
Has Manufacturing Date
No
Has Expiration Date
Yes
Has Donation ID
No

Sterilization

Is Sterile
No
Sterilization Prior Use
No

Product Codes

Code Name
JGY Colorimetric Method, Triglycerides
LBS Ldl & Vldl Precipitation, Cholesterol Via Esterase-Oxidase, Hdl
CHH Enzymatic Esterase--Oxidase, Cholesterol
CKA Nadh Oxidation/Nad Reduction, Alt/Sgpt
CGA Glucose Oxidase, Glucose
CIT Nadh Oxidation/Nad Reduction, Ast/Sgot

GMDN Terms

Code Name
52853 Glucose/ketone/lipid profile IVD, reagent
52925 Alanine aminotransferase (ALT) IVD, reagent
52955 Total aspartate aminotransferase (AST) IVD, reagent
53307 Glucose IVD, reagent

Identifiers

Type ID
Primary EABA40000301
Unit of Use EABA40000300

Customer Contacts

Storage Conditions

Type
Storage Environment Temperature
Temperature Range
36 – 46 Degrees Fahrenheit
Type
Storage Environment Temperature
Temperature Range
2 – 8 Degrees Celsius