FDA UDI In Commercial Distribution 🇺🇸 United States

DIMI RRT System

DI: B815DM850000 · Model: DM-850-00 · Dialco Medical Inc
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1

Let the assistant research this device

The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.

Free to try · every answer cites its records

Basic Information

Brand Name
DIMI RRT System
Primary DI
B815DM850000
Version / Model
DM-850-00
Catalog Number
DM-850-00
Company Name
Dialco Medical Inc
Labeler DUNS
203940515
Distribution Status
In Commercial Distribution
Device Count in Pkg
1
Record Status
Published
Publish Date
2020-09-22
Public Version
2
Public Version Date
2021-02-15
Public Version Status
Update
Public Device Record Key
91c224f8-0be5-483f-bbde-3127b83add36

Device Description

The DIMI RRT System is a software controlled device that performs the following functions: - Primes the disposable cassette automatically, - Pumps blood through the blood flow path of the disposable cassette, - Delivers anticoagulant into the blood flow path, - Pumps sterile infusion solutions into the blood flow path of the disposable according to therapy in use, - Pumps sterile dialysate into the fluid compartment of the filter in RRT therapies, - Controls the patient fluid removal or plasma loss according to the therapy in use, - Monitors the system and alerts the operator of abnormal situations through alarms. The DIMI RRT System has a touchscreen interface that provides operating instructions to the user. The system is used in conjunction with the cassette tubing set.

Device Characteristics

Single Use
No
Prescription Use (Rx)
Yes
Over the Counter (OTC)
No
Kit
No
Combination Product
No
HCT/P
No
Contains NRL
No
Not Made with NRL
No
MRI Safety
Labeling does not contain MRI Safety Information
Direct Marking Exempt
No
PM Exempt
Yes
Has Serial Number
Yes
Has Lot/Batch Number
No
Has Manufacturing Date
Yes
Has Expiration Date
No
Has Donation ID
No

Sterilization

Is Sterile
No
Sterilization Prior Use
No

Product Codes

Code Name
KDI Dialyzer, High Permeability With Or Without Sealed Dialysate System

GMDN Terms

Code Name
58131 Haemodialysis system, institutional/home-use

Identifiers

Type ID
Primary B815DM850000

Customer Contacts

Phone
18884264264

Storage Conditions

Type
Handling Environment Temperature
Temperature Range
15 – 35 Degrees Celsius
Type
Handling Environment Humidity
Temperature Range
30 – 75 Percent (%) Relative Humidity
Type
Storage Environment Temperature
Temperature Range
15 – 35 Degrees Celsius
Type
Storage Environment Humidity
Temperature Range
30 – 75 Percent (%) Relative Humidity
Type
Handling Environment Atmospheric Pressure
Temperature Range
85 – 106 KiloPascal