FDA UDI
In Commercial Distribution
🇺🇸 United States
Flotec
DI: B741MC0
·
Model: Mass Casualty Assembly
·
FLOTEC INC
Product Codes
1
GMDN Terms
3
Identifiers
1
Pkg Device Count
1
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- Flotec
- Primary DI
- B741MC0
- Version / Model
- Mass Casualty Assembly
- Company Name
- FLOTEC INC
- Labeler DUNS
- 103643730
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2020-02-27
- Public Version
- 4
- Public Version Date
- 2023-02-20
- Public Version Status
- Update
- Public Device Record Key
- 9e53fe00-46d9-4731-bfda-7bc197c4c934
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Conditional
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| BYX | Tubing, Pressure And Accessories | Anesthesiology | 868.5860 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 14239 | High-pressure medical gas hose | A length of flexible tube intended to deliver and withstand gases under very high pressure, e.g., greater than 200 bar/3000 pounds per square inch (psi). It may be composed of any of several malleable or semi-rigid materials (e.g., plastic, rubber, or nylon), and braided with cotton wool and/or stainless steel. It is typically used to transport high pressure compressed medical gas to a pressure regulating device. It is available in various lengths, including standard coil lengths. This is a reusable device. | No | Active |
| 43438 | Non-fixed medical gas cylinder regulator | A reduction valve designed to be attached through a gastight connector (e.g., a pin-index or bull-nosed screw thread connection) to the valve stem of a medical gas (e.g., carbon dioxide, oxygen, nitrous oxide, gas mixture) cylinder to reduce high, variable gas pressure to a lower, constant working pressure (excludes procedure-dedicated valves). It can be a single or a dual stage regulator, usually of a piston or diaphragm design. It will have a safety relief valve to avoid excessive pressure due to increased ambient temperatures, and it may have associated devices (e.g., a manometer, flowmeter) to display the available gas reserve of a gas cylinder, the working pressure and/or the flow rate. | No | Active |
| 61366 | Medical gas flowmeter, dial-type | A device intended to regulate the flow of a medical gas [e.g., oxygen (O2), carbon dioxide (CO2), nitrous oxide (N2O), helium/oxygen gas mixture (heliox), medical air] during various procedures (e.g., therapeutic administration, anaesthesia, insufflation during surgery). It has a pre-calibrated adjustable flow selection dial intended to control the gas flow rate; it is not intended to provide flow rate measurements. It will be calibrated to a specific medical gas and have a dedicated flow rate range, therefore some types may be dedicated to a specific patient group (e.g., neonate, infant, adult) or clinical use. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | B741MC0 | HIBCC |
Customer Contacts
- Phone
- 3172736960
- [email protected]