Vios Monitoring System Pulse Oximetry Sensor
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- Vios Monitoring System Pulse Oximetry Sensor
- Primary DI
- B595L2050R0
- Version / Model
- L2050R Pulse Oximetry Sensor
- Catalog Number
- L2050R
- Company Name
- MURATA VIOS, INC.
- Labeler DUNS
- 026867345
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2020-04-27
- Public Version
- 6
- Public Version Date
- 2025-03-24
- Public Version Status
- Update
- Public Device Record Key
- bc012b67-d88e-449f-8b4c-2037bdb9f5e0
Device Description
The Vios Monitoring System (VMS) Adapter and Chest Sensor are intended for use by medically qualified personnel for physiological vital signs monitoring of adult (18+) patients in healthcare facilities. It is indicated for use in monitoring of 7-Lead ECG, heart rate, respiratory rate, pulse rate, functional oxygen saturation of arterial hemoglobin, non-invasive blood pressure (NIBP) continuously and patient posture and activity. VMS allows for the input of body temperature and can display data from peripheral devices. VMS can generate alerts when rate-based cardiac arrhythmias are detected and when physiological vital signs fall outside of selected parameters. The non-invasive blood pressure tracking is based on Pulse Arrival Time (PAT) which is obtained utilizing ECG and PPG signals, following a calibration process using an FDA-cleared oscillometric blood pressure monitor. This feature is not intended for use in critical care environment. VMS can also generate alerts when cardiac arrhythmias (Tachycardia, Bradycardia, Asystole, Ventricular Tachycardia/Ventricular Fibrillation and Atrial Fibrillation/Atrial Flutter) are detected. The ECG rhythm analysis is intended for use by medically qualified professionals in the identification of arrhythmia events and to aid in clinical review of arrhythmia and medical interventions. The VMS Adapter and Chest Sensor are intended to be used by Vios-trained clinical professionals who also have a working knowledge of medical procedures, practices, and terminology, as required for monitoring patients.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Unsafe
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DQA | Oximeter | Cardiovascular | 870.2700 | 2 |
| DXN | System, Measurement, Blood-Pressure, Non-Invasive | Cardiovascular | 870.1130 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 37808 | Pulse oximeter probe, reusable | A photoelectric device designed to be applied externally to a body site (e.g., fingertip, ear lobe, bridge of nose, toe, or bridge of the foot) for the transcutaneous measurement of haemoglobin oxygen saturation (SpO2) in arterial blood using signals produced by a light-emitting diode (LED) and received by a photodetector. The signals are subsequently transmitted to an oximeter/monitor (not included) which measures and displays the SpO2. This is a reusable device. | No | Active |
| 47582 | Pulse Co-oximeter probe, reusable | A photoelectric component of a pulse Co-oximeter that is applied externally to a body part (e.g., a fingertip for adults, the hand or foot for neonates), for the transcutaneous multiwave measurement of carboxy-haemoglobin saturation (SpCO) and typically several other related parameters such as haemoglobin oxygen saturation (SpO2), methaemoglobin saturation (SpMet), haemoglobin concentration (SpHb), haematocrit, and pulse rate using light detection. Signals from the probe, produced by a light-emitting diode (LED) and a receiving detector, are used to calculate results which are digitally displayed on the Co-oximeter's computerized unit. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | B595L2050R0 | HIBCC | ||||
| Package | B595L2050R1 | HIBCC | case | 50 | In Commercial Distribution | |
| Package | B595L2050R2 | HIBCC | case | 8 | In Commercial Distribution |
Customer Contacts
- Phone
- +1-866-990-1434
- [email protected]
- Phone
- +918044324109
- [email protected]
Premarket Submissions
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- -40 – 70 Degrees Celsius
- Type
- Storage Environment Humidity
- Temperature Range
- 10 – 95 Percent (%) Relative Humidity
- Type
- Storage Environment Atmospheric Pressure
- Temperature Range
- 80 – 106 KiloPascal
- Type
- Handling Environment Temperature
- Temperature Range
- 10 – 40 Degrees Celsius
- Type
- Handling Environment Humidity
- Temperature Range
- 10 – 95 Percent (%) Relative Humidity
- Type
- Handling Environment Atmospheric Pressure
- Temperature Range
- 80 – 106 KiloPascal