Vios Monitoring System Chest Sensor
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- Vios Monitoring System Chest Sensor
- Primary DI
- B595CS20500
- Version / Model
- CS2050 Chest Sensor
- Catalog Number
- CS2050
- Company Name
- MURATA VIOS, INC.
- Labeler DUNS
- 026867345
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2020-04-02
- Public Version
- 7
- Public Version Date
- 2025-03-24
- Public Version Status
- Update
- Public Device Record Key
- f634dc85-68a3-4493-9a46-307983fbc8df
Device Description
The Vios Monitoring System (VMS) Adapter and Chest Sensor are intended for use by medically qualified personnel for physiological vital signs monitoring of adult (18+) patients in healthcare facilities. It is indicated for use in monitoring of 7-Lead ECG, heart rate, respiratory rate, pulse rate, functional oxygen saturation of arterial hemoglobin, non-invasive blood pressure (NIBP) continuously and patient posture and activity. VMS allows for the input of body temperature and can display data from peripheral devices. VMS can generate alerts when rate-based cardiac arrhythmias are detected and when physiological vital signs fall outside of selected parameters. The non-invasive blood pressure tracking is based on Pulse Arrival Time (PAT) which is obtained utilizing ECG and PPG signals, following a calibration process using an FDA-cleared oscillometric blood pressure monitor. This feature is not intended for use in critical care environment. VMS can also generate alerts when cardiac arrhythmias (Tachycardia, Bradycardia, Asystole, Ventricular Tachycardia/Ventricular Fibrillation and Atrial Fibrillation/Atrial Flutter) are detected. The ECG rhythm analysis is intended for use by medically qualified professionals in the identification of arrhythmia events and to aid in clinical review of arrhythmia and medical interventions. The VMS Adapter and Chest Sensor are intended to be used by Vios-trained clinical professionals who also have a working knowledge of medical procedures, practices, and terminology, as required for monitoring patients.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Unsafe
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DRT | Monitor, Cardiac (Incl. Cardiotachometer & Rate Alarm) | Cardiovascular | 870.2300 | 2 |
| DRG | Transmitters And Receivers, Physiological Signal, Radiofrequency | Cardiovascular | 870.2910 | 2 |
| DQA | Oximeter | Cardiovascular | 870.2700 | 2 |
| DPZ | Oximeter, Ear | Cardiovascular | 870.2710 | 2 |
| QYW | Hospital Cardiac Telemetry | Cardiovascular | 870.1025 | 2 |
| DXN | System, Measurement, Blood-Pressure, Non-Invasive | Cardiovascular | 870.1130 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 43239 | Cardiac arrhythmia monitoring system | An assembly of devices comprised of modules or components (e.g., monitors, recorders, amplifiers) intended to be used to continually detect, measure, and display the electrical activity of the heart and to produce a visible or audible signal/alarm when an atrial or ventricular arrhythmia, such as a premature contraction or ventricular fibrillation, exists. | No | Active |
| 65834 | Wearable multiple vital physiological parameter monitoring system | A portable assembly of electrically-powered devices intended to be worn by a patient in a healthcare or homecare setting for intermittent assessment or continuous monitoring, exclusively by a healthcare professional, of several vital physiologic parameters [e.g., electrocardiogram (ECG), noninvasive blood pressure (NIBP), pulse rate, haemoglobin oxygen saturation (SpO2), haematocrit]. It includes both physiological parameter sensors, probes, and/or electrodes (e.g., ECG electrodes, blood pressure cuff, skin patch) and processing hardware with dedicated software. It may include a monitoring screen or allow for remote communication with a smart device or central database. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | B595CS20500 | HIBCC | ||||
| Package | B595L2050G1 | HIBCC | case | 32 | Not in Commercial Distribution | 2020-07-22 |
Customer Contacts
- Phone
- 866-990-1434
- [email protected]
- Phone
- +918044324109
- [email protected]
Premarket Submissions
Storage Conditions
- Type
- Handling Environment Temperature
- Temperature Range
- 10 – 40 Degrees Celsius
- Type
- Handling Environment Humidity
- Temperature Range
- 10 – 95 Percent (%) Relative Humidity
- Type
- Storage Environment Atmospheric Pressure
- Temperature Range
- 80 – 106 KiloPascal
- Type
- Storage Environment Humidity
- Temperature Range
- 10 – 95 Percent (%) Relative Humidity
- Type
- Storage Environment Temperature
- Temperature Range
- -40 – 70 Degrees Celsius
- Type
- Handling Environment Atmospheric Pressure
- Temperature Range
- 80 – 106 KiloPascal