FDA UDI In Commercial Distribution 🇺🇸 United States

Vios Monitoring System Bedside Monitor

DI: B595BSM20500 · Model: BSM2050 Software · MURATA VIOS, INC.
Product Codes
6
GMDN Terms
4
Identifiers
1
Pkg Device Count
1

Let the assistant research this device

The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.

Free to try · every answer cites its records

Basic Information

Brand Name
Vios Monitoring System Bedside Monitor
Primary DI
B595BSM20500
Version / Model
BSM2050 Software
Catalog Number
BSM2050
Company Name
MURATA VIOS, INC.
Labeler DUNS
026867345
Distribution Status
In Commercial Distribution
Device Count in Pkg
1
Record Status
Published
Publish Date
2020-05-01
Public Version
7
Public Version Date
2025-03-24
Public Version Status
Update
Public Device Record Key
c35163a8-e679-418a-a3c3-44fdb1ab96bf

Device Description

The Vios Monitoring System (VMS) Bedside Monitor (BSM) is intended for use by medically qualified personnel for physiological vital signs monitoring of adult (18+) patients in healthcare facilities. It is indicated for use in monitoring of 7-Lead ECG, heart rate, respiratory rate, pulse rate, functional oxygen saturation of arterial hemoglobin, non-invasive blood pressure (NIBP) continuously and patient posture and activity. VMS allows for the input of body temperature and can display data from peripheral devices. VMS can generate alerts when rate-based cardiac arrhythmias are detected and when physiological vital signs fall outside of selected parameters. The non-invasive blood pressure tracking is based on Pulse Arrival Time (PAT) which is obtained utilizing ECG and PPG signals, following a calibration process using an FDA-cleared oscillometric blood pressure monitor. This feature is not intended for use in critical care environment. VMS can also generate alerts when cardiac arrhythmias (Tachycardia, Bradycardia, Asystole, Ventricular Tachycardia/Ventricular Fibrillation and Atrial Fibrillation/Atrial Flutter) are detected. The ECG rhythm analysis is intended for use by medically qualified professionals in the identification of arrhythmia events and to aid in clinical review of arrhythmia and medical interventions. The VMS BSM is intended to be used by Vios-trained clinical professionals who also have a working knowledge of medical procedures, practices, and terminology, as required for monitoring patients.

Device Characteristics

Single Use
No
Prescription Use (Rx)
No
Over the Counter (OTC)
No
Kit
No
Combination Product
No
HCT/P
No
Contains NRL
No
Not Made with NRL
No
MRI Safety
Labeling does not contain MRI Safety Information
Direct Marking Exempt
No
PM Exempt
No
Has Serial Number
No
Has Lot/Batch Number
Yes
Has Manufacturing Date
Yes
Has Expiration Date
No
Has Donation ID
No

Sterilization

Is Sterile
No
Sterilization Prior Use
No

Product Codes

Code Name
DRG Transmitters And Receivers, Physiological Signal, Radiofrequency
DPZ Oximeter, Ear
DQA Oximeter
DRT Monitor, Cardiac (Incl. Cardiotachometer & Rate Alarm)
QYW Hospital Cardiac Telemetry
DXN System, Measurement, Blood-Pressure, Non-Invasive

GMDN Terms

Code Name
33586 General-purpose multi-parameter bedside monitor
43239 Cardiac arrhythmia monitoring system
45607 Pulse oximeter
47582 Pulse Co-oximeter probe, reusable

Identifiers

Type ID
Primary B595BSM20500

Customer Contacts

Phone
866-990-1434

Premarket Submissions

Submission Number Supplement Number
K172586 000
K232354 000
K241728 000