Sonoclot® Reference Viscosity Oil Quality Control Kit
Basic Information
- Brand Name
- Sonoclot® Reference Viscosity Oil Quality Control Kit
- Primary DI
- B55890013021
- Version / Model
- 900-1302
- Catalog Number
- 900-1302
- Company Name
- SIENCO, INC.
- Labeler DUNS
- 064039514
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 24
- Record Status
- Published
- Publish Date
- 2021-07-19
- Public Version
- 1
- Public Version Date
- 2021-07-27
- Public Version Status
- New
- Public Device Record Key
- 968ecf46-feee-4a55-918e-fb3c49c65ad9
Device Description
The Reference Viscosity Oil QC test is a simple means of verifying proper operation of the Sonoclot Analyzer. This test consists of a two point verification of the electromechanical oscillator and also ensures that the heating control is operating accurately. The two verification points are: 1) Probe-In-Air, and 2) Probe-In-Oil. The Probe-In-Air is the response of the electromechanical oscillator to air. The Probe-In-Oil is the response of the electromechanical oscillator to the reference viscosity liquid. Since the viscosity of the reference viscosity fluid is significantly temperature dependent, the Probe-In-Oil test point also verifies the temperature regulation. The QC test should be run each day the Sonoclot Analyzer is used or as required by your institution. Each Reference Viscosity Quality Control Kit contains 24 cuvettes, 24 probes, 1 vial of reference viscosity oil with end cap, and these instructions. These supplies provide 24 QC tests for the analyzer.
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| JPA | System, Multipurpose For In Vitro Coagulation Studies | Hematology | 864.5425 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 30590 | Multiple coagulation factor IVD, control | A material which is used to verify the performance of an assay intended to be used for the qualitative and/or quantitative determination of one or multiple coagulation factors, coagulation intermediates and/or their activated components in a clinical specimen. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Unit of Use | B55890013020 | HIBCC | ||||
| Primary | B55890013021 | HIBCC |
Customer Contacts
- Phone
- 303-420-1148
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K952560 | 000 |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- – 25 Degrees Celsius